BTCYT5MPW

Agilent BioTek Cytation 5 Cell Imaging Multi-Mode Reader

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Type

Cell Imaging Multi-Mode Microplate Reader

Camera

Sony CMOS, 16-bit Gray Scale, Standard or WFOV

Absorbance Range

230 to 999 nm, 1 nm increments

Dynamic Range

Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades

Contrast Methods

Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast

Includes

Wide FOV camera; Fluorescence/brightfield/color brightfield/phase contrast imaging; Monochromator-based UV-Vis absorbance/fluorescence intensity/time resolved fluorescence (secondary)/luminescence

No. of Dispensers

2 Syringe Pumps

Reading Options

End point, kinetic, spectral scanning and well area scanning

Objectives

1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x

Temperature Range (Metric)

4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)

Depth (Metric)

51.4 cm

Height (Metric)

44.5 cm

Weight (Metric)

36.3 kg

Width (Metric)

41.6 cm

Wattage

250 W max.

Shaking

Linear, Orbital, Double Orbital

CO2 Concentration Range

0 to 20%

Accuracy

Monochromator: ±2 nm; Dispenser: ±1 μL or 2%

For Use With (Equipment)

BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible

Dispense Volume

5 to 1000 μL, 1 μL increments

Model

CYT5MPW

Plate Type

Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates; Take3 Plate compatible

Light Source

Xenon Flash; 100 mW 680 nm laser (Alpha Detection)

Software Compatibility

Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option)

Depth (English)

20.2 in.

Height (English)

17.5 in.

Weight (English)

80 lb.

Width (English)

16.4 in.

Certifications/Compliance

CE and TUV marked. RoHS compliant.

Related Products

Img

Fischer Scientific

BTCYT5MW

--

Img

Fischer Scientific

BTCYT5MPV

--

Img

Fischer Scientific

BTCYT5MV

--

Img

Fischer Scientific

BTCYT5FW

--

Img

Fischer Scientific

BTCYT5MFW

--

Img

Fischer Scientific

BTCYT5FAW

--

Img

Fischer Scientific

BTCYT5MFAW

--

Img

Fischer Scientific

BTCYT5FV

--

Description

  • Cytation 5 combines automated microscopy and conventional microplate detection in a configurable, upgradable platform
  • The microscopy module offers up to 60x magnification in fluorescence, brightfield, high contrast brightfield, color brightfield, and phase contrast to address many applications and workflows The multi-mode detection modules include filter- and monochromator-based fluorescence detection, luminescence, and UV-Vis absorbance detection
  • Gen5 software provides complete control over all imaging and data capture, plus powerful image and data analysis.

Compare Similar Items

Show Difference

Img

Fischer Scientific

BTCYT5MPW

--


Type:
Cell Imaging Multi-Mode Microplate Reader

Camera:
Sony CMOS, 16-bit Gray Scale, Standard or WFOV

Absorbance Range:
230 to 999 nm, 1 nm increments

Dynamic Range:
Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades

Contrast Methods:
Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast

Includes:
Wide FOV camera; Fluorescence/brightfield/color brightfield/phase contrast imaging; Monochromator-based UV-Vis absorbance/fluorescence intensity/time resolved fluorescence (secondary)/luminescence

No. of Dispensers:
2 Syringe Pumps

Reading Options:
End point, kinetic, spectral scanning and well area scanning

Objectives:
1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x

Temperature Range (Metric):
4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)

Depth (Metric):
51.4 cm

Height (Metric):
44.5 cm

Weight (Metric):
36.3 kg

Width (Metric):
41.6 cm

Wattage:
250 W max.

Shaking:
Linear, Orbital, Double Orbital

CO2 Concentration Range:
0 to 20%

Accuracy:
Monochromator: ±2 nm; Dispenser: ±1 μL or 2%

For Use With (Equipment):
BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible

Dispense Volume:
5 to 1000 μL, 1 μL increments

Model:
CYT5MPW

Plate Type:
Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates; Take3 Plate compatible

Light Source:
Xenon Flash; 100 mW 680 nm laser (Alpha Detection)

Software Compatibility:
Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option)

Depth (English):
20.2 in.

Height (English):
17.5 in.

Weight (English):
80 lb.

Width (English):
16.4 in.

Certifications/Compliance:
CE and TUV marked. RoHS compliant.

Img

Fischer Scientific

BTCYT5MV

--


Type:
Cell Imaging Multi-Mode Microplate Reader

Camera:
Sony CMOS, 16-bit Gray Scale, Standard or WFOV

Absorbance Range:
230 to 999 nm, 1 nm increments

Dynamic Range:
Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades

Contrast Methods:
Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast

Includes:
Fluorescence/brightfield/color brightfield imaging; Monochromator-based UV-Vis absorbance;/fluorescence intensity/time resolved fluorescence (secondary)/luminescence

No. of Dispensers:
2 Syringe Pumps

Reading Options:
End point, kinetic, spectral scanning and well area scanning

Objectives:
1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x

Temperature Range (Metric):
4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)

Depth (Metric):
51.4 cm

Height (Metric):
44.5 cm

Weight (Metric):
36.3 kg

Width (Metric):
41.6 cm

Wattage:
250 W max.

Shaking:
Linear, Orbital, Double Orbital

CO2 Concentration Range:
0 to 20%

Accuracy:
Monochromator: ±2 nm; Dispenser: ±1 μL or 2%

For Use With (Equipment):
BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible

Dispense Volume:
5 to 1000 μL, 1 μL increments

Model:
CYT5MV

Plate Type:
Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates; Take3 Plate compatible

Light Source:
Xenon Flash; 100 mW 680 nm laser (Alpha Detection)

Software Compatibility:
Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option)

Depth (English):
20.2 in.

Height (English):
17.5 in.

Weight (English):
80 lb.

Width (English):
16.4 in.

Certifications/Compliance:
CE and TUV marked. RoHS compliant.

Img

Fischer Scientific

BTCYT5MW

--


Type:
Cell Imaging Multi-Mode Microplate Reader

Camera:
Sony CMOS, 16-bit Gray Scale, Standard or WFOV

Absorbance Range:
230 to 999 nm, 1 nm increments

Dynamic Range:
Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades

Contrast Methods:
Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast

Includes:
Wide FOV camera; Fluorescence/brightfield/color brightfield imaging; Monochromator-based UV-Vis absorbance/fluorescence intensity/time resolved fluorescence (secondary)/luminescence

No. of Dispensers:
2 Syringe Pumps

Reading Options:
End point, kinetic, spectral scanning and well area scanning

Objectives:
1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x

Temperature Range (Metric):
4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)

Depth (Metric):
51.4 cm

Height (Metric):
44.5 cm

Weight (Metric):
36.3 kg

Width (Metric):
41.6 cm

Wattage:
250 W max.

Shaking:
Linear, Orbital, Double Orbital

CO2 Concentration Range:
0 to 20%

Accuracy:
Monochromator: ±2 nm; Dispenser: ±1 μL or 2%

For Use With (Equipment):
BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible

Dispense Volume:
5 to 1000 μL, 1 μL increments

Model:
CYT5MW

Plate Type:
Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates; Take3 Plate compatible

Light Source:
Xenon Flash; 100 mW 680 nm laser (Alpha Detection)

Software Compatibility:
Gen5 Microplate Reader and Imager Software included; Gen5 Image+ and Image Prime software available for full image analysis; Gen5 Secure for 21 CFR Part 11 compliance (option)

Depth (English):
20.2 in.

Height (English):
17.5 in.

Weight (English):
80 lb.

Width (English):
16.4 in.

Certifications/Compliance:
CE and TUV marked. RoHS compliant.

Img

Fischer Scientific

BTCYT5PV

--


Type:
Cell Imaging Only Microplate Reader

Camera:
Sony CMOS, 16-bit Gray Scale, Standard or WFOV

Absorbance Range:
__

Dynamic Range:
Absorbance: 0 to 4 OD; Fluorescence Intensity: 7 decades; Luminesence: >6 decades

Contrast Methods:
Fluorescence, phase contrast, brightfield, high contrast brightfield, color brightfield and phase contrast

Includes:
Fluorescence/brightfield/color brightfield/phase contrast imaging

No. of Dispensers:
__

Reading Options:
__

Objectives:
1.25x, 2.5x (2.25x eff), 2.5x (2.75x eff), 4x, 10x, 20x, 40x, 60x

Temperature Range (Metric):
4-Zone incubation to 65°C with Condensation Control (±0.2°C at 37°C)

Depth (Metric):
51.4 cm

Height (Metric):
44.5 cm

Weight (Metric):
36.3 kg

Width (Metric):
41.6 cm

Wattage:
250 W max.

Shaking:
Linear, Orbital, Double Orbital

CO2 Concentration Range:
0 to 20%

Accuracy:
__

For Use With (Equipment):
BioStack and Third Party Automation Compatible; BioSpa 8 Automated Incubator Compatible

Dispense Volume:
__

Model:
CYT5PV

Plate Type:
Monochromator: 6- to 384-well plates; Filters: 6-to 1536 well plates; Imaging: 6-to 1536 well plates

Light Source:
__

Software Compatibility:
__

Depth (English):
20.2 in.

Height (English):
17.5 in.

Weight (English):
80 lb.

Width (English):
16.4 in.

Certifications/Compliance:
CE and TUV marked. RoHS compliant.