4530449

Thermo Scientific™ Validex™ Count Precision Size Standards

Validate the performance of liquid particle counters with Thermo Scientific™ Validex™ Count Precision Size Standards.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Additive

Contains trace amount of surfactant

Content And Storage

Unless otherwise stated, refrigerate (2° to 8°C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand or vortex mixer.

Description

Designed specifically for the drinking water industry to validate the performance of liquid particle counters.

For Use With (Application)

Liquid Particle Counter Validation

Product Type

Count Control Particles

Quantity

500 mL

Size Distribution

<3

Concentration

1000 particles/mL ± 10%

Contents

Polymer particles in water

Color

White or Colorless

Material

Polystyrene

Includes

Certificate of Calibration and Traceability to NIST

Refractive Index

1.59 at 589nm (25°C)

Stability

Product stable for a minimum of 3 months

Related Products

Img

Fischer Scientific

09-980-238

--

Img

Fischer Scientific

09-980-237

--

Img

Fischer Scientific

09-980-230

--

Img

Fischer Scientific

09-980-227

--

Img

Fischer Scientific

09-980-234

--

Img

Fischer Scientific

09-980-229

--

Img

Fischer Scientific

09-980-226

--

Img

Fischer Scientific

09-980-232

--

Description

  • Validate the performance of liquid particle counters with Thermo Scientific™ Validex™ Count Precision Size Standards
  • Excellent for instrument calibration and verification in the drinking water industry and for low level liquid particle counting and calibration, standards contain NIST™-traceable polymer particles packaged in ultrapure water at concentrations ideal for use in validating the performance of liquid particle counters
  • Particle counting in the drinking water industry has rapidly become an indispensable technology for optimizing water quality
  • The majority of particle counters used in the drinking water industry operate on the principle of single particle light obscuration
  • Features: Composition of suspension optimized to promote dispersion of particles Contains 500mL of suspension at a nominal concentration of 1000 particles per mL Stir bar included in the bottle to aid dispersion Certified concentration Ultraclean diluent No dilution required Sample directly from bottle to avoid contamination Larger volume for appropriate testing

Compare Similar Items

Show Difference

Img

Fischer Scientific

4530449

Validate the performance of liquid ...


Additive:
Contains trace amount of surfactant

Content And Storage:
Unless otherwise stated, refrigerate (2° to 8°C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand or vortex mixer.

Description:
Designed specifically for the drinking water industry to validate the performance of liquid particle counters.

For Use With (Application):
Liquid Particle Counter Validation

Product Type:
Count Control Particles

Quantity:
500 mL

Size Distribution:
<3

Concentration:
1000 particles/mL ± 10%

Contents:
Polymer particles in water

Color:
White or Colorless

Material:
Polystyrene

Includes:
Certificate of Calibration and Traceability to NIST

Refractive Index:
1.59 at 589nm (25°C)

Stability:
Product stable for a minimum of 3 months

Img

Fischer Scientific

4530456

Optimize research in light scatteri...


Additive:
Contains trace amount of surfactant to inhibit agglomeration and promote stability

Content And Storage:
Unless otherwise stated, refrigerate (2° to 8°C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand or vortex mixer.

Description:
Particles useful for such applications as filter evaluation, checking and testing, light scattering research, fluid mechanics research, aerosol particle generation, dispersion studies, and many other research and development projects. They are not intended for use in instrument calibration.

For Use With (Application):
Aerosol Particle Generation, Dispersion, Filter Evaluation, Light Scattering, Particle Generation

Product Type:
Polymer Particle Suspensions

Quantity:
__

Size Distribution:
__

Concentration:
10%

Contents:
__

Color:
White or Colorless

Material:
Polystyrene

Includes:
General product handling insert sheet

Refractive Index:
1.59 at 589nm (25°C)

Stability:
Product stable for a minimum of 24 months

Img

Fischer Scientific

4530459

Meet the need for particulate mater...


Additive:
Contains trace amount of surfactant to inhibit agglomeration and promote stability

Content And Storage:
Unless otherwise stated, refrigerate (2° to 8°C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand or vortex mixer.

Description:
Particles useful for such applications as filter evaluation, checking and testing, light scattering research, fluid mechanics research, aerosol particle generation, dispersion studies, and many other research and development projects. They are not intended for use in instrument calibration.

For Use With (Application):
__

Product Type:
Polymer Particle Suspensions

Quantity:
__

Size Distribution:
__

Concentration:
10%

Contents:
__

Color:
White or Colorless

Material:
Polystyrene

Includes:
General product handling insert sheet

Refractive Index:
1.59 at 589nm (25°C)

Stability:
Product stable for a minimum of 24 months

Img

Fischer Scientific

4530462

Meet the need for particulate mater...


Additive:
Contains trace amount of surfactant to inhibit agglomeration and promote stability

Content And Storage:
Unless otherwise stated, refrigerate (2° to 8°C) product when not in use but do not freeze. Store upright and keep bottle tightly sealed. Mix product with gentle inversion by hand or vortex mixer.

Description:
Particles useful for such applications as filter evaluation, checking and testing, light scattering research, fluid mechanics research, aerosol particle generation, dispersion studies, and many other research and development projects. They are not intended for use in instrument calibration.

For Use With (Application):
Aerosol Particle Generation, Dispersion, Filter Evaluation, Light Scattering, Particle Generation

Product Type:
Polymer Particle Suspensions

Quantity:
__

Size Distribution:
__

Concentration:
10%

Contents:
__

Color:
White or Colorless

Material:
Polystyrene

Includes:
General product handling insert sheet

Refractive Index:
1.59 at 589nm (25°C)

Stability:
Product stable for a minimum of 24 months