08-878-6

Thermo Scientific™ Dionex™ IonPac™ NS2 5μm Analytical & Guard Columns

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 08-878-6-Each-of-1 In Stock ₹ 1,42,286.28

08-878-6 - Each of 1

₹ 1,42,286.28

In Stock

Quantity

1

Base Price: ₹ 1,42,286.28

GST (18%): ₹ 25,611.53

Total Price: ₹ 1,67,897.81

Column Type

Analytical Column

Flow Rate

0.5 to 1.0 (Recommended)

Particle Size

5 μm

Packing Material

Spherical, high-purity, porous

Pore Size

120 &‌Aring;

Surface Area

300 m²/g

Length (Metric)

250 mm

Column Chemistry

Polar-embedded C18

Max. Pressure

4000 psi (275 bar)

Stationary Phase

IonPac NS2

pH

2.0 to 9.5

Solvents

Compatible with 0 to 100% aqueous eluents. Compatible with most HPLC solvents, except THF 20% max.

Temperature (Metric)

20°C to 35°C

Diameter (Metric)

4 mm

Related Products

Img

Fischer Scientific

08-878-7

--

Img

Fischer Scientific

6162060

Order the Thermo Scientific™ Dionex...

Img

Thermo Scientific™

DX066766

--

Img

Fischer Scientific

09-928-140

--

Img

Fischer Scientific

09-928-141

--

Img

Thermo Scientific™

03-050-847

--

Img

Fischer Scientific

09-928-138

--

Img

Fischer Scientific

09-928-139

--

Description

  • Get high-performance analysis of hydrophobic amines and acids using suppressed conductivity detection using Thermo Scientific™ Dionex™ IonPac™ NS2 silica-based, high-efficiency, reversed-phase columns
  • This column is designed for mobile phase ion chromatography (MPIC) applications which use eluents containing: trifluoroacetic acid (TFA), heptafluorobutyric acid (HFBA), hexanesulfonic acid (HSA), octanesulfonic acid (OSA), tetrapropylammoium (TPA) borate, tetrabutylammonium (TBA) borate, and sodium borate
  • The Dionex IonPac NS2 column is also appropriate for conventional reversed-phase liquid chromatography (LC) applications
  • MPIC is a method in which an ion-pairing agent in the eluent enhances retention for charged analytes on a hydrophobic column, and then is removed by the suppressor to provide selective, sensitive detection of the analytes
  • For analysis of cations, heptafluorobutyric acid is one such agent that is amenable to suppression
  • Main column features include: Excellent resolution Good peak shape High efficiency Rugged packed bed Eluent Operational Guidelines Anions typically use 5–10mM sodium borate, 0.5–5mM TPA, or TBA borate pH 8–9 prepared from boric acid and the corresponding hydroxide
  • When using gradient elution with a Thermo Scientific™ Dionex™ ASRS™ Anion Self-Regenerating Suppressor, we recommend maintaining constant sodium/TBA concentration and varying the organic solvent
  • Cations typically use 0.5–10 mM TFA, HFBA, HSA or OSA
  • When using gradient elution with a Thermo Scientific™ Dionex™ CSRS™ Cation Self-Regenerating Suppressor, we recommend maintaining constant acid concentration and varying the organic solvent
  • Solvent composition is limited based on the solvent compatibility of the suppressor
  • Flush all solvents out of the suppressor with DI water before shutting down the system
  • See suppressor manuals for detailed instructions and solvent compatibility limits
  • Suppressor Operational Guidelines The 4mm Thermo Scientific™ Dionex™ AERS™ Anion Electrolytically Regenerated Suppressors, Dionex ASRS suppressors, Thermo Scientific™ Dionex™ CERS™ Cation Electrolytically Regenerated Suppressors, and Dionex CSRS suppressors are compatible with ≤40% acetonitrile and require operation in the external water mode
  • Thermo Scientific™ Dionex™ AMMS™ Anion MicroMembrane™ Suppressors are compatible with all solvent conditions with 5–50mN sulfuric acid at 2–10mL/min
  • Thermo Scientific™ Dionex™ CMMS™ Cation MicroMembrane™ Suppressors are compatible with all solvent conditions with 20–100mM tetrabutylammonium hydroxide at 2–10mL/min
  • See suppressor manuals for detailed instructions and solvent compatibility limits.

Compare Similar Items

Show Difference

Img

Fischer Scientific

08-878-6

--


Column Type:
Analytical Column

Flow Rate:
0.5 to 1.0 (Recommended)

Particle Size:
5 μm

Packing Material:
Spherical, high-purity, porous

Pore Size:
120 &‌Aring;

Surface Area:
300 m²/g

Length (Metric):
250 mm

Column Chemistry:
Polar-embedded C18

Max. Pressure:
4000 psi (275 bar)

Stationary Phase:
IonPac NS2

pH:
2.0 to 9.5

Solvents:
Compatible with 0 to 100% aqueous eluents. Compatible with most HPLC solvents, except THF 20% max.

Temperature (Metric):
20°C to 35°C

Diameter (Metric):
4 mm

Img

Fischer Scientific

08-878-7

--


Column Type:
Analytical Column

Flow Rate:
0.5 to 1.0 (Recommended)

Particle Size:
5 μm

Packing Material:
Spherical, high-purity, porous

Pore Size:
120 &‌Aring;

Surface Area:
300 m²/g

Length (Metric):
150 mm

Column Chemistry:
Polar-Embedded C18

Max. Pressure:
4000 psi (275 bar)

Stationary Phase:
IonPac NS2

pH:
2.0 to 9.5

Solvents:
Compatible with 0 to 100% aqueous eluents. Compatible with most HPLC solvents, except THF 20% max.

Temperature (Metric):
20°C to 35°C

Diameter (Metric):
4 mm

Img

Fischer Scientific

08-880

--


Column Type:
__

Flow Rate:
__

Particle Size:
__

Packing Material:
__

Pore Size:
__

Surface Area:
__

Length (Metric):
11.4 cm

Column Chemistry:
__

Max. Pressure:
__

Stationary Phase:
__

pH:
__

Solvents:
__

Temperature (Metric):
__

Diameter (Metric):
__

Img

Fischer Scientific

08-882

--


Column Type:
__

Flow Rate:
__

Particle Size:
__

Packing Material:
__

Pore Size:
__

Surface Area:
__

Length (Metric):
11.4 cm

Column Chemistry:
__

Max. Pressure:
__

Stationary Phase:
__

pH:
__

Solvents:
__

Temperature (Metric):
__

Diameter (Metric):
__