14-685-207

Hamilton™ Microliter™ and Gastight™ Syringes: Model 701 for Agilent 7673, 7683, 7693 and 6850 ALS GC

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-685-207-Each-of-1 In Stock ₹ 5,347.50

14-685-207 - Each of 1

₹ 5,347.50

In Stock

Quantity

1

Base Price: ₹ 5,347.50

GST (18%): ₹ 962.55

Total Price: ₹ 6,310.05

Material

Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner

0.019 in.

Diameter (Metric) Inner Needle

0.13 mm

Diameter (English) Outer

0.26 in.

Diameter (Metric) Outer

6.6 mm

Length (English) Needle

1.71 in.

Max. Pressure

2000 psi

Max. Temperature (Metric)

155°C

Model

701 N (Cemented Needle)

Min. Temperature (Metric)

10°C

Volume (Metric)

10 μL

Needle Point Style

Sharp, Bevel, Curved, Non-coring

Connection Type

Cemented

Needle Gauge

26s G

Diameter (English) Inner Needle

0.005 in.

Diameter (English) Outer Needle

0.0187 in.

Diameter (Metric) Inner

0.485 mm

Diameter (Metric) Outer Needle

0.47 mm

Product Type

Microliter Syringe

Max. Temperature (English)

239°F

Min. Temperature (English)

50°F

Needle Point Number

2

Quantity

Ea.

Length (Metric) Needle

43.4 cm

For Use With (Equipment)

Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers

Related Products

Img

Fischer Scientific

14-816-209

--

Img

Fischer Scientific

14-815-27

--

Img

Fischer Scientific

14-685-206

--

Img

Fischer Scientific

14-815-25

--

Img

Fischer Scientific

14-815-24

--

Img

Fischer Scientific

14-815-48

--

Img

Fischer Scientific

14-816-226

--

Img

Fischer Scientific

14-813-264

--

Description

  • Microliter syringes have a stainless steel plunger that is hand fitted to the glass barrel and are designed for liquid sampling
  • Syringe Terminations Cemented Needle (N) - For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Removable Needle (RN) - The needles are removable and are a Hamilton-specific design
  • The design allows the needles to seat precisely at the zero graduation mark of the syringe
  • Users can select the needle gauge, length, and point style to optimize the syringe for custom applications
  • Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging
  • Autoclavable when disassembled
  • Repeated autoclaving will shorten syringe life
  • Needle Point Styles Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 23s or 26s Point Style AS - Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration
  • Available gauges: 23s, 26s, 23s-26s

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-685-207

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.019 in.

Diameter (Metric) Inner Needle:
0.13 mm

Diameter (English) Outer:
0.26 in.

Diameter (Metric) Outer:
6.6 mm

Length (English) Needle:
1.71 in.

Max. Pressure:
2000 psi

Max. Temperature (Metric):
155°C

Model:
701 N (Cemented Needle)

Min. Temperature (Metric):
10°C

Volume (Metric):
10 μL

Needle Point Style:
Sharp, Bevel, Curved, Non-coring

Connection Type:
Cemented

Needle Gauge:
26s G

Diameter (English) Inner Needle:
0.005 in.

Diameter (English) Outer Needle:
0.0187 in.

Diameter (Metric) Inner:
0.485 mm

Diameter (Metric) Outer Needle:
0.47 mm

Product Type:
Microliter Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Length (Metric) Needle:
43.4 cm

For Use With (Equipment):
Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers

Img

Hamilton™

14-685-217

--


Material:
__

Diameter (English) Inner:
__

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
__

Diameter (Metric) Outer:
__

Length (English) Needle:
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

Needle Point Style:
__

Connection Type:
__

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
__

Diameter (Metric) Outer Needle:
__

Product Type:
BFP Sealing Washer

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Length (Metric) Needle:
__

For Use With (Equipment):
__

Img

Fischer Scientific

14-685-501

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.018 in.

Diameter (Metric) Inner Needle:
0.013 cm

Diameter (English) Outer:
0.25 in.

Diameter (Metric) Outer:
0.66 cm

Length (English) Needle:
2 in.

Max. Pressure:
68.9 bar

Max. Temperature (Metric):
50°C

Model:
1701

Min. Temperature (Metric):
20°C

Volume (Metric):
10 μL

Needle Point Style:
Blunt

Connection Type:
Fixed

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.005 in.

Diameter (English) Outer Needle:
0.028 in.

Diameter (Metric) Inner:
0.046 cm

Diameter (Metric) Outer Needle:
0.071 cm

Product Type:
Gastight Autosampler Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
68°F

Needle Point Number:
__

Quantity:
Ea.

Length (Metric) Needle:
__

For Use With (Equipment):
CTC LC PAL, HTC PAL, HTS PAL HTX PAL, PAL HTC-xt, PAL HTS-xt, PAL HTX-xt

Img

Fischer Scientific

14-685-502

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.028 in.

Diameter (Metric) Inner Needle:
0.013 cm

Diameter (English) Outer:
0.305 in.

Diameter (Metric) Outer:
0.775 cm

Length (English) Needle:
2 in.

Max. Pressure:
68.9 bar

Max. Temperature (Metric):
50°C

Model:
1702

Min. Temperature (Metric):
20°C

Volume (Metric):
25 μL

Needle Point Style:
Blunt

Connection Type:
Cemented

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.005 in.

Diameter (English) Outer Needle:
0.028 in.

Diameter (Metric) Inner:
0.072 cm

Diameter (Metric) Outer Needle:
0.071 cm

Product Type:
Gastight Autosampler Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
68°F

Needle Point Number:
__

Quantity:
Ea.

Length (Metric) Needle:
__

For Use With (Equipment):
CTC LC PAL, HTC PAL, HTS PAL HTX PAL, PAL HTC-xt, PAL HTS-xt, PAL HTX-xt