14-815-49

Hamilton™ Microliter™ and Gastight™ Syringes: Model 75 for Agilent 7673, 7683, 7693 and 6850 ALS GC

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Pack of 6 14-815-49-Pack-of-6 In Stock ₹ 44,491.20

14-815-49 - Pack of 6

₹ 44,491.20

In Stock

Quantity

1

Base Price: ₹ 44,491.20

GST (18%): ₹ 8,008.416

Total Price: ₹ 52,499.616

Material

Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner

0.014 in.

Diameter (Metric) Inner Needle

0.25 mm

Diameter (English) Outer

0.26 in.

Diameter (Metric) Outer

6.6 mm

Length (English)

1.7 in.

Length (Metric)

43 mm

Max. Pressure

2000 psi

Max. Temperature (Metric)

50°C

Model

75 N (Cemented Needle)

Min. Temperature (Metric)

10°C

Volume (Metric)

5 μL

For Use With (Equipment)

Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers

Needle Gauge

23s G

Diameter (English) Inner Needle

0.01 in.

Diameter (English) Outer Needle

0.025 in.

Diameter (Metric) Inner

0.343 mm

Diameter (Metric) Outer Needle

0.64 mm

Length (English) Needle

1.71 in.

Product Type

Microliter Syringe

Max. Temperature (English)

122°F

Min. Temperature (English)

50°F

Needle Point Number

AS

Quantity

6 Pk.

Needle Point Style

Cone

Connection Type

Cemented

Related Products

Img

Fischer Scientific

14-815-45

--

Img

Fischer Scientific

14-816-226

--

Img

Fischer Scientific

14-815-28

--

Img

Fischer Scientific

14-815-48

--

Img

Fischer Scientific

14-813-257

--

Img

Fischer Scientific

14-815-27

--

Img

Fischer Scientific

14-813-256

--

Img

Fischer Scientific

14-815-25

--

Description

  • Microliter syringes have a stainless steel plunger that is hand fitted to the glass barrel and are designed for liquid sampling
  • Syringe Terminations Cemented Needle (N) - For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Removable Needle (RN) - The needles are removable and are a Hamilton-specific design
  • The design allows the needles to seat precisely at the zero graduation mark of the syringe
  • Users can select the needle gauge, length, and point style to optimize the syringe for custom applications
  • Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging
  • Autoclavable when disassembled
  • Repeated autoclaving will shorten syringe life
  • Needle Point Styles Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 23s or 26s Point Style AS - Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration
  • Available gauges: 23s, 26s, 23s-26s

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-815-49

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.014 in.

Diameter (Metric) Inner Needle:
0.25 mm

Diameter (English) Outer:
0.26 in.

Diameter (Metric) Outer:
6.6 mm

Length (English):
1.7 in.

Length (Metric):
43 mm

Max. Pressure:
2000 psi

Max. Temperature (Metric):
50°C

Model:
75 N (Cemented Needle)

Min. Temperature (Metric):
10°C

Volume (Metric):
5 μL

For Use With (Equipment):
Agilent 7673, 7683, 6850 Automatic Liquid Sampler, Gas Chromatography Autosamplers

Needle Gauge:
23s G

Diameter (English) Inner Needle:
0.01 in.

Diameter (English) Outer Needle:
0.025 in.

Diameter (Metric) Inner:
0.343 mm

Diameter (Metric) Outer Needle:
0.64 mm

Length (English) Needle:
1.71 in.

Product Type:
Microliter Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
AS

Quantity:
6 Pk.

Needle Point Style:
Cone

Connection Type:
Cemented

Img

Fischer Scientific

14-815-490

--


Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.01 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.02 in.

Diameter (Metric) Outer:
0.51 mm

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

For Use With (Equipment):
TLL Syringes and LT or TLL Connectors

Needle Gauge:
25 G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.26 mm

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
2 in.

Product Type:
Replacement Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Cone with Side Port

Connection Type:
__

Img

Fischer Scientific

14-815-491

--


Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.01 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.02 in.

Diameter (Metric) Outer:
0.46 mm

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

For Use With (Equipment):
TLL Syringes and LT or TLL Connectors

Needle Gauge:
26 G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.26 mm

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
2 in.

Product Type:
Replacement Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Cone with Side Port

Connection Type:
__

Img

Fischer Scientific

14-815-492

--


Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.0059 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.028 in.

Diameter (Metric) Outer:
0.72 mm

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

For Use With (Equipment):
TLL Syringes and LT or TLL Connectors

Needle Gauge:
22s G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.15 mm

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
2 in.

Product Type:
Replacement Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Cone with Side Port

Connection Type:
__