14-818-131

Hamilton™ CTC PAL™ Autosampler S-Line Syringes

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-818-131-Each-of-1 In Stock ₹ 6,288.66

14-818-131 - Each of 1

₹ 6,288.66

In Stock

Quantity

1

Base Price: ₹ 6,288.66

GST (18%): ₹ 1,131.959

Total Price: ₹ 7,420.619

Autoclavable

Not Autoclavable

Needle Gauge

23s G

Diameter (Metric) Inner Needle

0.11 mm

Diameter (English) Outer

0.25 in.

Diameter (Metric) Outer Needle

0.64 mm

Length (English) Needle

2 in.

Max. Pressure

2000 psi

Min. Temperature (English)

68°F

Min. Temperature (Metric)

20°C

Volume (Metric)

10 μL

Needle Point Style

AS

Material

Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle

0.004 in.

Diameter (English) Outer Needle

0.02 in.

Diameter (Metric) Outer

6.6 mm

For Use With (Application)

GC autosampler injections

Product Type

S-Line Syringe

Max. Temperature (Metric)

50°C

Model

1701 N

Quantity

Ea.

Length (Metric) Needle

51 mm

Connection Type

Cemented

Related Products

Img

Fischer Scientific

14-818-132

--

Img

Fischer Scientific

14-818-133

--

Img

Fischer Scientific

14-818-130

--

Img

Fischer Scientific

14-818-134

--

Img

Fischer Scientific

14-818-139

--

Img

Fischer Scientific

14-818-135

--

Img

Fischer Scientific

14-818-136

--

Img

Fischer Scientific

14-818-140

--

Description

  • The economical S-Line Syringe is hand made from the highest quality materials to exceed your expectations for most standard chromatographic applications
  • The Gastight™ version of the S-Line syringe is an ideal choice for GC sample injections
  • It incorporates a precision-machined PTFE plunger tip which creates a leak-free seal
  • With the tight fit in the glass barrel, the tip wipes the interior of the syringe barrel free of sample, minimizing sample carryover
  • This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze
  • The cost-effective choice for CTC PAL autosampler applications Deliver great performance in everyday use for GC injections at an exceptional value Precision-machined PTFE plunger tip which creates a leak-free seal Tight fit in glass barrel minimizes sample carryover

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-818-131

--


Autoclavable:
Not Autoclavable

Needle Gauge:
23s G

Diameter (Metric) Inner Needle:
0.11 mm

Diameter (English) Outer:
0.25 in.

Diameter (Metric) Outer Needle:
0.64 mm

Length (English) Needle:
2 in.

Max. Pressure:
2000 psi

Min. Temperature (English):
68°F

Min. Temperature (Metric):
20°C

Volume (Metric):
10 μL

Needle Point Style:
AS

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Outer:
6.6 mm

For Use With (Application):
GC autosampler injections

Product Type:
S-Line Syringe

Max. Temperature (Metric):
50°C

Model:
1701 N

Quantity:
Ea.

Length (Metric) Needle:
51 mm

Connection Type:
Cemented

Img

Fischer Scientific

14-818-132

--


Autoclavable:
Not Autoclavable

Needle Gauge:
26s G

Diameter (Metric) Inner Needle:
0.11 mm

Diameter (English) Outer:
0.25 in.

Diameter (Metric) Outer Needle:
0.47 mm

Length (English) Needle:
2 in.

Max. Pressure:
2000 psi

Min. Temperature (English):
68°F

Min. Temperature (Metric):
20°C

Volume (Metric):
10 μL

Needle Point Style:
AS

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.01 in.

Diameter (Metric) Outer:
6.6 mm

For Use With (Application):
GC autosampler injections

Product Type:
S-Line Syringe

Max. Temperature (Metric):
50°C

Model:
701 N

Quantity:
Ea.

Length (Metric) Needle:
51 mm

Connection Type:
Cemented

Img

Fischer Scientific

14-818-133

--


Autoclavable:
Not Autoclavable

Needle Gauge:
23s G

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.25 in.

Diameter (Metric) Outer Needle:
0.64 mm

Length (English) Needle:
2 in.

Max. Pressure:
2000 psi

Min. Temperature (English):
68°F

Min. Temperature (Metric):
20°C

Volume (Metric):
10 μL

Needle Point Style:
AS

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Outer:
6.6 mm

For Use With (Application):
GC autosampler injections

Product Type:
S-Line Syringe

Max. Temperature (Metric):
50°C

Model:
701 N

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Cemented

Img

Fischer Scientific

14-818-134

--


Autoclavable:
Not Autoclavable

Needle Gauge:
23 G

Diameter (Metric) Inner Needle:
0.32 mm

Diameter (English) Outer:
0.31 in.

Diameter (Metric) Outer Needle:
0.64 mm

Length (English) Needle:
2 in.

Max. Pressure:
2000 psi

Min. Temperature (English):
68°F

Min. Temperature (Metric):
20°C

Volume (Metric):
25 μL

Needle Point Style:
AS

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.01 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Outer:
7.9 mm

For Use With (Application):
GC autosampler injections

Product Type:
S-Line Syringe

Max. Temperature (Metric):
50°C

Model:
1702 N

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Cemented