13-684-106

Hamilton™ 1700 Series Gastight™ Syringes: LTN Termination

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 13-684-106-Each-of-1 In Stock ₹ 7,101.48

13-684-106 - Each of 1

₹ 7,101.48

In Stock

Quantity

1

Base Price: ₹ 7,101.48

GST (18%): ₹ 1,278.266

Total Price: ₹ 8,379.746

Autoclavable

Not Autoclavable

Needle Gauge

22 G

Diameter (English) Inner Needle

0.01 in.

Diameter (English) Outer Needle

0.02 in.

Diameter (Metric) Inner

3.26 mm

Diameter (Metric) Outer Needle

0.72 mm

Length (English)

2 in.

Length (Metric)

51 mm

Max. Pressure

700 psi

Max. Temperature (Metric)

50°C

Model

1750

Min. Temperature (Metric)

10°C

Volume (Metric)

500 μL

Needle Point Style

Sharp, Bevel, Curved, Non-coring

Material

Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner

0.12 in.

Diameter (Metric) Inner Needle

0.41 mm

Diameter (English) Outer

0.3 in.

Diameter (Metric) Outer

7.75 mm

For Use With (Application)

Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle

2 in.

Product Type

Gastight Syringe

Max. Temperature (English)

122°F

Min. Temperature (English)

50°F

Needle Point Number

2

Quantity

Ea.

Length (Metric) Needle

51 mm

Connection Type

Luer Tip, Cemented

Related Products

Img

Fischer Scientific

14-813-142

--

Img

Fischer Scientific

14-815-113

--

Img

Fischer Scientific

4895515

Gastight version of the original 70...

Img

Fischer Scientific

14-815-97

--

Img

Hamilton™

14-813-137

--

Img

Fischer Scientific

14-815-115

--

Img

Fischer Scientific

14-815-284

--

Img

Fischer Scientific

14-813-141

--

Description

  • Syringe series offers a variety of different terminations and needle options
  • 1700 Series Syringe Terminations Cemented Needle (N)- For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Luer Tip (LT)- The needles are removable and fit over a ground glass hub which is tapered in the shape of a male luer
  • The LT termination will accept most hypodermic needles but was designed specifically for use with Hamilton Kel-F needles
  • This termination increases the dead volume in the syringe, which may not be appropriate for some applications
  • Autoclavable when disassembled
  • Needle Point Styles (Point styles 4 and AS are available on request) Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 34-10 Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 34-10 Point Style 4 - Standard 12° beveled needle point is recommended for life science applications
  • Available gauges: 34-10
  • Special needle angles such as 0° to 60° available upon request
  • Point Style 5 - Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring
  • Available gauges: 26-10 Point Style AS - Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration
  • Available gauges: 26-10

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-684-106

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
0.01 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
3.26 mm

Diameter (Metric) Outer Needle:
0.72 mm

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
700 psi

Max. Temperature (Metric):
50°C

Model:
1750

Min. Temperature (Metric):
10°C

Volume (Metric):
500 μL

Needle Point Style:
Sharp, Bevel, Curved, Non-coring

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.12 in.

Diameter (Metric) Inner Needle:
0.41 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Length (Metric) Needle:
51 mm

Connection Type:
Luer Tip, Cemented

Img

Fischer Scientific

13-684-107

--


Autoclavable:
Not Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
4.61 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
200 psi

Max. Temperature (Metric):
115°C

Model:
1001

Min. Temperature (Metric):
__

Volume (Metric):
1 mL

Needle Point Style:
__

Material:
Borosilicate Glass (Barrel), PTFE (Tip)

Diameter (English) Inner:
0.181 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.355 in.

Diameter (Metric) Outer:
9.02 mm

For Use With (Application):
__

Length (English) Needle:
__

Product Type:
Gastight Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
No Needle Included

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Luer Lock

Img

Fischer Scientific

13-684-108

--


Autoclavable:
Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
7.29 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
200 psi

Max. Temperature (Metric):
115°C

Model:
1002

Min. Temperature (Metric):
__

Volume (Metric):
2.5 mL

Needle Point Style:
__

Material:
Borosilicate Glass (Barrel), PTFE (Tip)

Diameter (English) Inner:
0.28 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.4 in.

Diameter (Metric) Outer:
10.3 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Length (English) Needle:
__

Product Type:
Gastight Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
No Needle Included

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Luer Tip

Img

Hamilton™

13-684-109

--


Autoclavable:
Not Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
23 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
100 psi

Max. Temperature (Metric):
80°C

Model:
1025

Min. Temperature (Metric):
__

Volume (Metric):
25 mL

Needle Point Style:
__

Material:
PTFE (Tip), PTFE-tipped (Plunger)

Diameter (English) Inner:
0.9 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
1.07 in.

Diameter (Metric) Outer:
27.1 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Length (English) Needle:
__

Product Type:
Gastight Syringe

Max. Temperature (English):
176°F

Min. Temperature (English):
50°F

Needle Point Number:
No Needle Included

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Luer Lock