14-815-61

Hamilton™ 1700 Series Gastight™ Syringes: RN Termination

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-815-61-Each-of-1 In Stock ₹ 9,839.40

14-815-61 - Each of 1

₹ 9,839.40

In Stock

Quantity

1

Base Price: ₹ 9,839.40

GST (18%): ₹ 1,771.092

Total Price: ₹ 11,610.492

Autoclavable

Autoclavable

Needle Gauge

22s G

Diameter (English) Inner Needle

0.005 in.

Diameter (English) Outer Needle

0.02 in.

Diameter (Metric) Inner

1.03 mm

Diameter (Metric) Outer Needle

0.72 mm

Length (English)

2 in.

Length (Metric)

51 mm

Max. Pressure

1000 psi

Max. Temperature (Metric)

115°C

Model

1705

Min. Temperature (Metric)

10°C

Volume (Metric)

50 μL

Connection Type

Removable

Material

Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner

0.04 in.

Diameter (Metric) Inner Needle

0.15 mm

Diameter (English) Outer

0.3 in.

Diameter (Metric) Outer

7.75 mm

For Use With (Application)

Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle

2 in.

Product Type

Gastight Syringe

Max. Temperature (English)

239°F

Min. Temperature (English)

50°F

Needle Point Number

2

Quantity

Ea.

Needle Point Style

Sharp, Bevel, Curved, Non-coring

Related Products

Img

Fischer Scientific

14-815-80

--

Img

Fischer Scientific

14-815-37

--

Img

Fischer Scientific

14-815-97

--

Img

Fischer Scientific

14-815-281

--

Img

Fischer Scientific

14-815-113

--

Img

Fischer Scientific

14-815-11

--

Img

Fischer Scientific

14-815-282

--

Img

Fischer Scientific

14-815-280

--

Description

  • Syringe series offers a variety of different terminations and needle options
  • Removable Needle (RN)- The needles are removable and are a Hamilton-specific design
  • The design allows the needles to seat precisely at the zero graduation mark of the syringe
  • Users can select the needle gauge, length and point style to optimize the syringe for custom applications
  • Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging
  • Autoclavable when disassembled
  • Repeated autoclaving will shorten syringe life
  • Needle Point Styles (Point styles 4 and AS are available on request) Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 34-10 Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 34-10 Point Style 4 - Standard 12° beveled needle point is recommended for life science applications
  • Available gauges: 34-10
  • Special needle angles such as 0° to 60° available upon request
  • Point Style 5 - Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring
  • Available gauges: 26-10 Point Style AS - Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration
  • Available gauges: 26-10

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-815-61

--


Autoclavable:
Autoclavable

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.005 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
1.03 mm

Diameter (Metric) Outer Needle:
0.72 mm

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
1000 psi

Max. Temperature (Metric):
115°C

Model:
1705

Min. Temperature (Metric):
10°C

Volume (Metric):
50 μL

Connection Type:
Removable

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.04 in.

Diameter (Metric) Inner Needle:
0.15 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Needle Point Style:
Sharp, Bevel, Curved, Non-coring

Img

Fischer Scientific

14-815-610

--


Autoclavable:
Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.41 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

Connection Type:
__

Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.016 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.028 in.

Diameter (Metric) Outer:
0.72 mm

For Use With (Application):
__

Length (English) Needle:
2 in.

Product Type:
Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Blunt

Img

Fischer Scientific

14-815-611

--


Autoclavable:
Autoclavable

Needle Gauge:
23 G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.34 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

Connection Type:
__

Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.013 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.025 in.

Diameter (Metric) Outer:
0.64 mm

For Use With (Application):
__

Length (English) Needle:
2 in.

Product Type:
Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Blunt

Img

Fischer Scientific

14-815-612

--


Autoclavable:
Autoclavable

Needle Gauge:
24 G

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
0.31 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
__

Connection Type:
__

Material:
Nickel-plated Brass (Hub), Stainless Steel

Diameter (English) Inner:
0.012 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.022 in.

Diameter (Metric) Outer:
0.57 mm

For Use With (Application):
__

Length (English) Needle:
2 in.

Product Type:
Needle

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Quantity:
__

Needle Point Style:
Blunt