14-824-30

Hamilton™ 1700 Series Gastight™ Syringes: N Termination

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-824-30-Each-of-1 In Stock ₹ 6,588.12

14-824-30 - Each of 1

₹ 6,588.12

In Stock

Quantity

1

Base Price: ₹ 6,588.12

GST (18%): ₹ 1,185.862

Total Price: ₹ 7,773.982

Autoclavable

Not Autoclavable

Needle Gauge

22s G

Diameter (English) Inner Needle

0.0059 in.

Diameter (English) Outer Needle

0.0283 in.

Diameter (Metric) Inner

1.03 mm

Diameter (Metric) Outer Needle

0.72 mm

Length (English)

2 in.

Length (Metric)

51 mm

Max. Pressure

1000 psi

Max. Temperature (Metric)

50°C

Model

1705

Min. Temperature (Metric)

10°C

Volume (Metric)

50 μL

Connection Type

Cemented

Material

Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner

0.04 in.

Diameter (Metric) Inner Needle

0.15 mm

Diameter (English) Outer

0.3 in.

Diameter (Metric) Outer

7.75 mm

For Use With (Application)

Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle

2 in.

Product Type

Gastight Syringe

Max. Temperature (English)

122°F

Min. Temperature (English)

50°F

Needle Point Number

2

Quantity

Ea.

Needle Point Style

2

Related Products

Img

Fischer Scientific

14-813-136

--

Img

Fischer Scientific

13-684-100

--

Img

Fischer Scientific

14-813-138

--

Img

Fischer Scientific

14-813-140

--

Img

Fischer Scientific

14-815-99

--

Img

Fischer Scientific

14-813-133

--

Img

Hamilton™

14-813-137

--

Img

Fischer Scientific

14-813-139

--

Description

  • Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL Syringe series offers a variety of different terminations and needle options
  • 1700 Series Syringe Terminations Cemented Needle (N)- For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Needle Point Styles (Point styles 4 and AS are available on request) Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 34-10 Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 34-10 Point Style 4 - Standard 12° beveled needle point is recommended for life science applications
  • Available gauges: 34-10
  • Special needle angles such as 0° to 60° available upon request
  • Point Style 5 - Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring
  • Available gauges: 26-10 Point Style AS - Special conical style needle point used on autosampler syringes the non-coring needle point is recommended for septum penetration
  • Available gauges: 26-10

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-824-30

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.0059 in.

Diameter (English) Outer Needle:
0.0283 in.

Diameter (Metric) Inner:
1.03 mm

Diameter (Metric) Outer Needle:
0.72 mm

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
1000 psi

Max. Temperature (Metric):
50°C

Model:
1705

Min. Temperature (Metric):
10°C

Volume (Metric):
50 μL

Connection Type:
Cemented

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.04 in.

Diameter (Metric) Inner Needle:
0.15 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Needle Point Style:
2

Img

Fischer Scientific

14-824-32

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.0059 in.

Diameter (English) Outer Needle:
0.0283 in.

Diameter (Metric) Inner:
1.03 mm

Diameter (Metric) Outer Needle:
0.72 mm

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
2000 psi

Max. Temperature (Metric):
50°C

Model:
705

Min. Temperature (Metric):
__

Volume (Metric):
50 μL

Connection Type:
Cemented

Material:
Stainless Steel (Plunger)

Diameter (English) Inner:
0.041 in.

Diameter (Metric) Inner Needle:
0.15 mm

Diameter (English) Outer:
0.305 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
For dispensing low volumes to achieve the highest level of accuracy and precision possible

Length (English) Needle:
2 in.

Product Type:
Microliter Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
3

Quantity:
Ea.

Needle Point Style:
Blunt

Img

Fischer Scientific

14-824-34

--


Autoclavable:
Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
14.6 mm

Diameter (Metric) Outer Needle:
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
200 psi

Max. Temperature (Metric):
115°C

Model:
1010

Min. Temperature (Metric):
__

Volume (Metric):
10 mL

Connection Type:
Luer Tip

Material:
Borosilicate Glass (Barrel), PTFE (Tip)

Diameter (English) Inner:
0.57 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
0.695 in.

Diameter (Metric) Outer:
17.7 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Length (English) Needle:
__

Product Type:
Gastight Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
No Needle Included

Quantity:
Ea.

Needle Point Style:
__

Img

Fischer Scientific

14-824-35

--


Autoclavable:
Not Autoclavable

Needle Gauge:
26 G

Diameter (English) Inner Needle:
0.0102 in.

Diameter (English) Outer Needle:
0.018 in.

Diameter (Metric) Inner:
1.03 mm

Diameter (Metric) Outer Needle:
0.47 mm

Length (English):
2.5 in.

Length (Metric):
65 mm

Max. Pressure:
2000 psi

Max. Temperature (Metric):
50°C

Model:
705

Min. Temperature (Metric):
10°C

Volume (Metric):
50 μL

Connection Type:
Carbon Analyzer, Cemented

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.041 in.

Diameter (Metric) Inner Needle:
0.26 mm

Diameter (English) Outer:
0.305 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
Water analysis with total organic carbon

Length (English) Needle:
2.5 in.

Product Type:
Carbon Analyzer Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
3

Quantity:
Ea.

Needle Point Style:
Blunt