23-044-844

Siemens Healthineers RAPIDLab™ 1240 Blood Gas Analyzer

Manufacturer: Siemens Healthineers

Select a Size

Pack Size SKU Availability Price
Each of 1 23-044-844-Each-of-1 In Stock ₹ 30,98,213.16

23-044-844 - Each of 1

₹ 30,98,213.16

In Stock

Quantity

1

Base Price: ₹ 30,98,213.16

GST (18%): ₹ 5,57,678.369

Total Price: ₹ 36,55,891.529

Interface

USB (three ports), RS232 port, bar-code scanner port and RJ10/100 Base T Ethernet port

Analysis Time

∼60 sec.

Security

McAfee embedded control, firewall, verified system connection and encrypted patient data transfer via USB

Electrical Requirements

Rating: 150 VA, Voltage: 100/240 VAC, Freq: 50/60 Hz

Sample Type

Heparinized Whole Blood

Calibration

One point every 30 minutes to a maximum of 60 minutes; Full calibration every 8 hours

Volume (Metric)

pH only: 35 μL; Full menu: 90 μL

Certifications/Compliance

TUV-listed to IEC/EN 61010, 61010-2-101, 61010-2-081, CB Test Certificate, certified to CSA and UL

Related Products

Img

Siemens Healthineers

23-044-846

--

Img

Siemens Healthineers

23-044-845

--

Img

Siemens Healthineers

23-044-847

--

Img

Siemens Healthineers

23-044-871

--

Img

Moore Medical

19-815-372

--

Img

Fischer Scientific

23-044-851

--

Img

Fischer Scientific

23-044-839

--

Img

Fischer Scientific

23-044-838

--

Description

  • For medium- to high-volume critical care testing sites Full test menu from a small blood sample Self-contained, easily replaceable reagent and wash cartridges Easy-to-use system features three simple steps Enhanced system security with McAfee Embedded Control, firewall and verified system connection Immediate results available in just 1 minute Environmental Requirements: Temperature: 15 to 32°C Humidity: 5 to 90% noncondensing Barometric Pressure: 523 to 800 mmHg (69.7 to 106.7 kPa)

Compare Similar Items

Show Difference

Img

Siemens Healthineers

23-044-844

--


Interface:
USB (three ports), RS232 port, bar-code scanner port and RJ10/100 Base T Ethernet port

Analysis Time:
∼60 sec.

Security:
McAfee embedded control, firewall, verified system connection and encrypted patient data transfer via USB

Electrical Requirements:
Rating: 150 VA, Voltage: 100/240 VAC, Freq: 50/60 Hz

Sample Type:
Heparinized Whole Blood

Calibration:
One point every 30 minutes to a maximum of 60 minutes; Full calibration every 8 hours

Volume (Metric):
pH only: 35 μL; Full menu: 90 μL

Certifications/Compliance:
TUV-listed to IEC/EN 61010, 61010-2-101, 61010-2-081, CB Test Certificate, certified to CSA and UL

Img

Siemens Healthineers

23-044-845

--


Interface:
USB (three ports), RS232 port, bar-code scanner port and RJ10/100 Base T Ethernet port

Analysis Time:
∼60 sec.

Security:
McAfee embedded control, firewall, verified system connection and encrypted patient data transfer via USB

Electrical Requirements:
Rating: 150 VA, Voltage: 100/240 VAC, Freq: 50/60 Hz

Sample Type:
Heparinized Whole Blood

Calibration:
One point every 30 minutes to a maximum of 60 minutes; Full calibration every 8 hours

Volume (Metric):
pH only: 35 μL; CO-oximetry only: 100 μL; Full menu: 140 μL

Certifications/Compliance:
TUV-listed to IEC/EN 61010, 61010-2-101, 61010-2-081, CB Test Certificate, certified to CSA and UL

Img

Siemens Healthineers

23-044-846

--


Interface:
USB (three ports), RS232 port, bar-code scanner port and RJ10/100 Base T Ethernet port

Analysis Time:
∼60 sec.

Security:
McAfee embedded control, firewall, verified system connection and encrypted patient data transfer via USB

Electrical Requirements:
Rating: 150 VA, Voltage: 100/240 VAC, Freq: 50/60 Hz

Sample Type:
Heparinized Whole Blood

Calibration:
One point every 30 minutes to a maximum of 60 minutes; Full calibration every 8 hours

Volume (Metric):
pH only: 95 μL; Full menu: 125 μL

Certifications/Compliance:
TUV-listed to IEC/EN 61010, 61010-2-101, 61010-2-081, CB Test Certificate, certified to CSA and UL

Img

Siemens Healthineers

23-044-847

--


Interface:
USB (three ports), RS232 port, bar-code scanner port and RJ10/100 Base T Ethernet port

Analysis Time:
∼60 sec.

Security:
McAfee embedded control, firewall, verified system connection and encrypted patient data transfer via USB

Electrical Requirements:
Rating: 150 VA, Voltage: 100/240 VAC, Freq: 50/60 Hz

Sample Type:
Heparinized Whole Blood

Calibration:
One point every 30 minutes to a maximum of 60 minutes; Full calibration every 8 hours

Volume (Metric):
pH only: 95 μL; CO-oximetry only: 100 μL; Full menu: 175 μL

Certifications/Compliance:
TUV-listed to IEC/EN 61010, 61010-2-101, 61010-2-081, CB Test Certificate, certified to CSA and UL