23-601-539

HORIBA ABX SAS Yumizen C1200 Clinical Chemistry Analyzer

Manufacturer: HORIBA ABX SAS

Select a Size

Pack Size SKU Availability Price
Each of 1 23-601-539-Each-of-1 In Stock ₹ 1,91,08,122.00

23-601-539 - Each of 1

₹ 1,91,08,122.00

In Stock

Quantity

1

Base Price: ₹ 1,91,08,122.00

GST (18%): ₹ 34,39,461.96

Total Price: ₹ 2,25,47,583.96

Sample Type

Plasma, Serum, Urine

For Use With (Application)

Processing Chemistry Tests

Sample Dilution

Automatic sample dilution 1/2 to 1/202

Calibration

Endpoint, rate reaction, 2 point rat, immunoassay

Capacity

84 samples continuous loading

Distilled Water Consumption

22 L/hr.

Certifications/Compliance

CE Marked, FDA Cleared

Reaction Vessel

233 reusable high quality plastic cuvettes

Quantity

24

Dimensions (D x W x H)

124 x 85 x 110.8 cm (WxDxH) / 48 x 33 x 43 in. (WxDxH)

Depth (Metric)

85 cm

Height (Metric)

110.8 cm

Width (Metric)

122 cm

Amperage

2.6 kVA

Voltage

220 V

External Computer

Yes

Operating Environment

18°C to 30°C 40% to 70% with no condensation

Quality Control Details

Multi Cal, Protein Cal, Albumin U/CSF Cal, CRP Cl, RF Cal, Cystatin C Cal, Ferritin Cal, TPU Cal, HDL Cal, LDL Cal, hsCRP Cal, N multi, P multi, Protein L1,L2; Urine L1,L2;Albumin U/CSF L1,L2;CO2, Cystatin C L1,L2; Low CRPhs

Weight (English)

994 lb.

Description

Na+, K+,Cl- and Reference electrode

Analysis Time

12 minutes for one CMP panel 29 minutes for 20 CMP samples

Throughput

1200 Tests/hr.

Analytical Method

Spectrophotometry, Colorimetric and Turbidimetric

Cuvettes

Yes

Format

Floor Model

Includes

BOM List Analyzer, Computer, Monitor, Keyboard, Mouse, Power cords Printer Wash solutions Set of Electrodes ISE solutions and standards and USB key containing Daily guide, Operations manual

Read Length

3 to 15 minutes, measurement cycle of 13.5 seconds

Shipping Condition

Crates shipped on truck to hospital

Depth (English)

33 in.

Height (English)

43 in.

Width (English)

48 in.

Electrical Requirements

2.6 kVA, 220 V ± 10%, 50/60 Hz

Frequency

50/60 Hz

Data Management Features

Computer with keyboard

Laser Features

Yes

Operating System

Windows Operating System

ISE Type

Indirect

Weight (Metric)

451 kg

Related Products

Img

HORIBA ABX SAS

23-601-540

--

Img

Ortho-Clinical Diagnostics™

23-057-105

--

Img

GSD

23-700-100

--

Img

Thermo Scientific™

23-278-456

--

Img

Meridian Bioscience™

23-800-100

--

Img

Invitrogen™

LX2RPVERK25

--

Img

Abbott

07-P02-13A

--

Img

Invitrogen™

LX2RCALK25

--

Description

  • General Description: Analysis method types: Spectrophotometry, colorimetric and immunoassay Flexible Indirect ISE Na+, K+, and Cl- with reference electrode – reliable Throughput 1200 tests per hour Efficient workflow for labor savings Automatic maintenance during start-up and shutdown for labor savings Sample Handling: Sample tray holds 84 samples, continuous loading Sample probes liquid level sensing, cap/shock and clot detection Sample ID with Integrated barcode reader
  • Sample types: Serum, plasma and urine Sample collection format: 5, 7, 10 mL tubes and sample cups ISE sample volume: 1-25 uL (0.1 uL increment) Automatic sample dilution 1/2 to 1/200 Calibration and Control tray: 61 refrigerated positions for calibrators and controls Reagent Handling: Reagent tray: 2 trays with 45 reagent positions each Refrigeration: all reagents refrigerated at 208 °C Reagent Cartridge: 20 (with adaptors), 40 or 70 mL Dispensing system: Two reagent  probes, 3-part reagent capability Reagent ID: Integrated Barcode reader Reagent volume: 5-300 uL Reaction System: Reaction tray: 231 reusable high quality plastic cuvettes Reaction volume: 80 to 430 uL Temperature Reaction: 37 °C +/- 0.1 with inert bath oil Extended Reaction Time: 3, 4, 5, 10, 15 minutes Photometer reaction cycle: 21 or 31 minutes Homogenization  13.5 seconds Automatic correction: Rotation and repeated left-right movements by stirrers, serum blank, cell blank and measurement point change Optical System: Light source:  Halogen lamp with cooling system Principle wavelengths: Endpoint, rate reaction, 2 point rate, immunoassay 14 wavelengths (340-884 nm), mon and bichromatic Physical specifications: Analyzer Size: 122 W x 85 D x 110.8 H cm or 48 in
  • W x 33 in
  • D x 43 in
  • H Analyzer weight: 450 kgs / 992 Lbs with AL 1208 lbs Water Specifications: Conductivity < 1 us/cm

Compare Similar Items

Show Difference

Img

HORIBA ABX SAS

23-601-539

--


Sample Type:
Plasma, Serum, Urine

For Use With (Application):
Processing Chemistry Tests

Sample Dilution:
Automatic sample dilution 1/2 to 1/202

Calibration:
Endpoint, rate reaction, 2 point rat, immunoassay

Capacity:
84 samples continuous loading

Distilled Water Consumption:
22 L/hr.

Certifications/Compliance:
CE Marked, FDA Cleared

Reaction Vessel:
233 reusable high quality plastic cuvettes

Quantity:
24

Dimensions (D x W x H):
124 x 85 x 110.8 cm (WxDxH) / 48 x 33 x 43 in. (WxDxH)

Depth (Metric):
85 cm

Height (Metric):
110.8 cm

Width (Metric):
122 cm

Amperage:
2.6 kVA

Voltage:
220 V

External Computer:
Yes

Operating Environment:
18°C to 30°C 40% to 70% with no condensation

Quality Control Details:
Multi Cal, Protein Cal, Albumin U/CSF Cal, CRP Cl, RF Cal, Cystatin C Cal, Ferritin Cal, TPU Cal, HDL Cal, LDL Cal, hsCRP Cal, N multi, P multi, Protein L1,L2; Urine L1,L2;Albumin U/CSF L1,L2;CO2, Cystatin C L1,L2; Low CRPhs

Weight (English):
994 lb.

Description:
Na+, K+,Cl- and Reference electrode

Analysis Time:
12 minutes for one CMP panel 29 minutes for 20 CMP samples

Throughput:
1200 Tests/hr.

Analytical Method:
Spectrophotometry, Colorimetric and Turbidimetric

Cuvettes:
Yes

Format:
Floor Model

Includes:
BOM List Analyzer, Computer, Monitor, Keyboard, Mouse, Power cords Printer Wash solutions Set of Electrodes ISE solutions and standards and USB key containing Daily guide, Operations manual

Read Length:
3 to 15 minutes, measurement cycle of 13.5 seconds

Shipping Condition:
Crates shipped on truck to hospital

Depth (English):
33 in.

Height (English):
43 in.

Width (English):
48 in.

Electrical Requirements:
2.6 kVA, 220 V ± 10%, 50/60 Hz

Frequency:
50/60 Hz

Data Management Features:
Computer with keyboard

Laser Features:
Yes

Operating System:
Windows Operating System

ISE Type:
Indirect

Weight (Metric):
451 kg

Img

HORIBA ABX SAS

23-601-540

--


Sample Type:
Plasma, Serum or Urine

For Use With (Application):
Processing Chemistry Tests

Sample Dilution:
Automatic sample dilution 1/2 to 1/203

Calibration:
Endpoint, rate reaction, 2 point rat, immunoassay

Capacity:
84 samples continuous loading

Distilled Water Consumption:
23 L/hr.

Certifications/Compliance:
CE Marked, FDA Cleared

Reaction Vessel:
234 reusable high quality plastic cuvettes

Quantity:
24

Dimensions (D x W x H):
125 x 85 x 110.8 cm (WxDxH) / 48 x 33 x 43 in. (WxDxH)

Depth (Metric):
85 cm

Height (Metric):
110.8 cm

Width (Metric):
122 cm

Amperage:
2.6 kVA

Voltage:
220 V

External Computer:
Yes

Operating Environment:
18°C to 30°C 40% to 70% with no condensation

Quality Control Details:
Multi Cal, Protein Cal, Albumin U/CSF Cal, CRP Cl, RF Cal, Cystatin C Cal, Ferritin Cal, TPU Cal, HDL Cal, LDL Cal, hsCRP Cal, N multi, P multi, Protein L1,L2; Urine L1,L2;Albumin U/CSF L1,L2;CO2, Cystatin C L1,L2; Low CRPhs

Weight (English):
995 lb.

Description:
Na+, K+,Cl- and Reference electrode

Analysis Time:
12 minutes for one CMP panel 29 minutes for 20 CMP samples

Throughput:
1200 Tests/hr.

Analytical Method:
Spectrophotometry, Colorimetric and Turbidimetric

Cuvettes:
Yes

Format:
Floor Model

Includes:
BOM List Analyzer, Computer, Monitor, Keyboard, Mouse, Power cords Printer Wash solutions Set of Electrodes ISE solutions and standards and USB key containing Daily guide, Operations manual

Read Length:
3 to 15 minutes, measurement cycle of 13.5 seconds

Shipping Condition:
Crates shipped on truck to hospital

Depth (English):
33 in.

Height (English):
43 in.

Width (English):
48 in.

Electrical Requirements:
2.6 kVA, 220 V ± 10%, 50/60 Hz

Frequency:
50/60 Hz

Data Management Features:
Computer with keyboard

Laser Features:
Yes

Operating System:
Windows Operating System

ISE Type:
Indirect

Weight (Metric):
452 kg

Img

HORIBA

23-601-541

--


Sample Type:
Serum or Plasma

For Use With (Application):
Optimized UV-test technology according to IFCC

Sample Dilution:
__

Calibration:
__

Capacity:
__

Distilled Water Consumption:
__

Certifications/Compliance:
CE Marked

Reaction Vessel:
__

Quantity:
__

Dimensions (D x W x H):
__

Depth (Metric):
__

Height (Metric):
__

Width (Metric):
__

Amperage:
__

Voltage:
__

External Computer:
__

Operating Environment:
__

Quality Control Details:
__

Weight (English):
__

Description:
__

Analysis Time:
__

Throughput:
__

Analytical Method:
__

Cuvettes:
__

Format:
__

Includes:
__

Read Length:
__

Shipping Condition:
__

Depth (English):
__

Height (English):
__

Width (English):
__

Electrical Requirements:
__

Frequency:
__

Data Management Features:
__

Laser Features:
__

Operating System:
__

ISE Type:
__

Weight (Metric):
__

Img

HORIBA

23-601-542

--


Sample Type:
Serum or Plasma

For Use With (Application):
Photometric Test using Bromocresol Green

Sample Dilution:
__

Calibration:
__

Capacity:
__

Distilled Water Consumption:
__

Certifications/Compliance:
CE Marked

Reaction Vessel:
__

Quantity:
__

Dimensions (D x W x H):
__

Depth (Metric):
__

Height (Metric):
__

Width (Metric):
__

Amperage:
__

Voltage:
__

External Computer:
__

Operating Environment:
__

Quality Control Details:
__

Weight (English):
__

Description:
__

Analysis Time:
__

Throughput:
__

Analytical Method:
__

Cuvettes:
__

Format:
__

Includes:
__

Read Length:
__

Shipping Condition:
__

Depth (English):
__

Height (English):
__

Width (English):
__

Electrical Requirements:
__

Frequency:
__

Data Management Features:
__

Laser Features:
__

Operating System:
__

ISE Type:
__

Weight (Metric):
__