23-287-100

Ortho-Clinical Diagnostics™ Ortho VISION™ Analyzer

Manufacturer: Ortho-Clinical Diagnostics™

Select a Size

Pack Size SKU Availability Price
Each of 1 23-287-100-Each-of-1 In Stock ₹ 1,15,07,856.79

23-287-100 - Each of 1

₹ 1,15,07,856.79

In Stock

Quantity

1

Base Price: ₹ 1,15,07,856.79

GST (18%): ₹ 20,71,414.222

Total Price: ₹ 1,35,79,271.012

Type

ORTHO VISION Analyzer

For Use With (Application)

Automates in vitro Immunohematology testing of human blood utilizing ID-MTS™ Gel Card technology.

Depth (Metric)

107.4 cm

Height (Metric)

88.9 cm

Width (Metric)

107.4 cm

Frequency

50/60 Hz

Weight (Metric)

190 kg

Sample Type

Centrifuged Whole Blood, Plasma and Serum, Packed Red Blood Cells

Depth (English)

30.3 in.

Height (English)

35 in.

Width (English)

42.3 in.

Electrical Requirements

One dedicated (3-wired single phase; line-neutral and single circuit) AC power line for connection to facility power

Voltage

100 to 240VAC

Related Products

Img

Alcor™

22-000-124

--

Img

Alcor™

22-000-114

--

Img

Fischer Scientific

23-900-108

--

Img

HORIBA

23-450-042

--

Img

Streck

23-285-050

--

Img

Fischer Scientific

23-900-110

--

Img

Alcor™

22-000-447

--

Img

Fischer Scientific

23-024-627

--

Description

  • Column Agglutination Technology using ORTHO ID-MTS™ Gel card technology Automates test processing functions including liquid pipetting, reagent handling, incubation, centrifugation, reaction grading and interpretation and data management requirements using ORTHO ID-MTS™ Gel card technology and digital image processing Provides pre-qualification check of the front and back of every ORTHO ID-MTS™ Gel card Standalone instrument or interfaced to the Laboratory Information System (LIS) Monitors critical processing monitoring and provides for complete management of system maintenance and quality control Up to 42 samples can be loaded (six sample racks holding seven tubes each) Authorized personnel on an external computer and on the laboratory’s network can review results Can be connected either to a network printer or to a local printer ORTHO VISION Supply Drawer 120 ID-MTS™ Gel Cards (6 sleeves of 20) Reagent Red Blood Cell Supply 3 mL – 33 vials 10 mL – 18 vials Any combination of 3 racks can be used to accommodate Reagent Red Blood Cell (RRBC) testing needs
  • The 10 mL rack can accommodate reverse grouping and antibody detection (screen) RRBC
  • The 3 mL rack can accommodate reverse group, antibody detection and Antibody Identification RRBC
  • Diluent 2 x 100 mL for MTS™ Diluent 2 & MTS™ Diluent 2 Plus 2 x 10 mL for other diluents e-Connectivity Remote Connectivity Provides the ability to connect your system to Ortho Clinical Diagnostics in a way that enables remote diagnostics as well as, monitor and review system configuration, data, and performance
  • Communication Ports I/O ports include: 1 DB-9 serial port (RS-232 port for LIS support) 1 RJ45 LAN port supports port speeds of automatic, 10/100 Mbps with half and full duplex
  • 5 V 2.0/V 1.1 USB ports are available for: Printer Handheld barcode reader Other devices Specifications Supported Sample Types: Centrifuged whole blood, plasma and serum, packed red blood cells Sample and Test Processing: Continuous, random, STAT access and batch Operating Temperature: 18° to 30°C (64.4° to 86°F) Site Relative Humidity: 15 to 85% RH (non-condensing) Maximum Altitude: 2438m (8000 ft.) Heat Output: 3412 BTU/hr
  • Heated Incubator: 12 ORTHO ID-MTS™ Gel Cards Room Temperature Incubator: 16 ORTHO ID-MTS™ Gel Cards Centrifuge: two centrifuges; 10 ORTHO ID-MTS™ Gel Cards per centrifuge Waste: 5.2L, 80 ORTHO ID-MTS™ Gel Cards Power Requirements: one dedicated (3-wired single phase; line-neutral and single circuit) AC power line for connection to facility power
  • Input Voltage: 100 to 240V AC 50/60Hz 1000 VA Dimensions (D x W x H): 77 x 107.4 x 88.9cm (30.3 x 42.3 x 35 in.) Weight: 190kg (419 lbs) Applications ABO/Rh Typing, Antibody Screen, Antibody Identification, Crossmatch, Direct Antiglobulin, Antigen Testing, QC testing, Serial Dilutions for Titration Studies, Monoclonal Rh Phenotyping, Selected Cell Panels

Compare Similar Items

Show Difference

Img

Ortho-Clinical Diagnostics™

23-287-100

--


Type:
ORTHO VISION Analyzer

For Use With (Application):
Automates in vitro Immunohematology testing of human blood utilizing ID-MTS™ Gel Card technology.

Depth (Metric):
107.4 cm

Height (Metric):
88.9 cm

Width (Metric):
107.4 cm

Frequency:
50/60 Hz

Weight (Metric):
190 kg

Sample Type:
Centrifuged Whole Blood, Plasma and Serum, Packed Red Blood Cells

Depth (English):
30.3 in.

Height (English):
35 in.

Width (English):
42.3 in.

Electrical Requirements:
One dedicated (3-wired single phase; line-neutral and single circuit) AC power line for connection to facility power

Voltage:
100 to 240VAC

Img

Ortho-Clinical Diagnostics™

23-287-101

--


Type:
Multipurpose Table

For Use With (Application):
Ensures safety and protects ORTHO VISION Analyzer.

Depth (Metric):
76 cm

Height (Metric):
76 cm

Width (Metric):
123 cm

Frequency:
__

Weight (Metric):
__

Sample Type:
__

Depth (English):
__

Height (English):
__

Width (English):
__

Electrical Requirements:
__

Voltage:
__

Img

Fischer Scientific

23-287-247

--


Type:
Anti-A BioClone™

For Use With (Application):
To determine ABO cell type

Depth (Metric):
__

Height (Metric):
__

Width (Metric):
__

Frequency:
__

Weight (Metric):
__

Sample Type:
__

Depth (English):
__

Height (English):
__

Width (English):
__

Electrical Requirements:
__

Voltage:
__

Img

Fischer Scientific

23-287-248

--


Type:
Anti-B BioClone™

For Use With (Application):
To determine ABO cell type

Depth (Metric):
__

Height (Metric):
__

Width (Metric):
__

Frequency:
__

Weight (Metric):
__

Sample Type:
__

Depth (English):
__

Height (English):
__

Width (English):
__

Electrical Requirements:
__

Voltage:
__