14-387-700

Thermo Scientific™ KingFisher™ Duo Prime Purification System

Manufacturer: Thermo Scientific™

Select a Size

Pack Size SKU Availability Price
Each of 1 14-387-700-Each-of-1 In Stock ₹ 40,46,988.00

14-387-700 - Each of 1

₹ 40,46,988.00

In Stock

Quantity

1

Base Price: ₹ 40,46,988.00

GST (18%): ₹ 7,28,457.84

Total Price: ₹ 47,75,445.84

Volume (Metric) Processing

96 DW plate 50 to 1000 μL, 24 DW plate 200 to 5000 μL, Elution strip 30 to 130 μL

Collection Efficiency of Particles

≥95%

Display

LCD color display

For Use With (Application)

DNA and RNA isolation from various starting materials, proteomic applications, cell isolation

Particle Size (Metric)

ca. >1 μm

Quantity

Each

Type of Magnet Head

12-pin or 6-pin

UV Lamp

8W

Plate Type

Microtiter 96 Deepwell plate (95040450); KingFisher Flex 24 Deepwell plate (95040470)

Depth (English)

18.1 in.

Height (English)

13.4 in.

Weight (English)

37.5 lb.

Width (English)

15.7 in.

Description

KingFisher Duo Prime

Cooling Temperature

4° to 75°C in RT (elution strip)

Elution Strip

Special design, 1 x 12 format

Heating Temperature

10°C to 75°C in RT (plate row A)

Ports

USB

Samples per Run

Up to 12 (12-pin magnet head); Up to 6 (6-pin magnet head)

UV Exposure Time

Up to 16 hr.

Memory

Space for ca. 200 protocols

Protocol Import

Using PC or USB memory device

Depth (Metric)

46 cm

Height (Metric)

34 cm

Weight (Metric)

17 kg

Width (Metric)

40 cm

Related Products

Img

Thermo Scientific™

A39956PKG

--

Img

Thermo Scientific™

50-152-7925

--

Img

Thermo Scientific™

50-152-7924

--

Img

Thermo Scientific™

50-152-7923

--

Img

Thermo Scientific™

50-152-7922

--

Img

Fischer Scientific

54-009-40

--

Img

Fischer Scientific

54-009-20

--

Img

Fischer Scientific

54-009-30

--

Description

  • Description Reap high yields of quality nucleic acids from a variety of starting materials with the Thermo Scientific™ KingFisher™ Duo Prime purification system
  • This compact instrument is ideal for laboratories requiring nucleic acid purification, and is easily modified for use in proteomics and cell isolation
  • It provides excellent reproducibility with minimal hands-on time, and has a small footprint in the lab
  • New features, including a UV lamp for easy decontamination and optional bar-code reader enhance functionality
  • Features of the KingFisher Duo Prime system Isolates DNA, RNA and proteins from a variety of starting materials including cell-free body fluids, blood, bacteria, cell cultures, tissue and plant samples; with volumes ranging up to 5 mL Automated magnetic bead technology, included in all KingFisher systems, allows excellent recovery of samples with great reproducibility and efficiency Built-in UV lamp delivers easy and effective decontamination Optional bar-code reader allows users to track samples directly in the internal software Use with optimized KingFisher Pure DNA and RNA isolation kits and protocols for a complete, easy-to-use solution, or customize with Thermo Scientific™ BindIt™ software to create your own protocols Available in eight languages: English, French, Spanish, German, Chinese, Japanese, Russian and Portuguese Operating with BindIt Software Protocols can be modified or developed, as well as imported directly to the instrument using PC or via USB stick Able to save run log files individually, providing traceability and complete data management Flexible, fast and compact size system for diverse applications Recommended for: DNA and RNA isolation from various starting materials, proteomic applications, cell isolation

Compare Similar Items

Show Difference

Img

Thermo Scientific™

14-387-700

--


Volume (Metric) Processing:
96 DW plate 50 to 1000 μL, 24 DW plate 200 to 5000 μL, Elution strip 30 to 130 μL

Collection Efficiency of Particles:
≥95%

Display:
LCD color display

For Use With (Application):
DNA and RNA isolation from various starting materials, proteomic applications, cell isolation

Particle Size (Metric):
ca. >1 μm

Quantity:
Each

Type of Magnet Head:
12-pin or 6-pin

UV Lamp:
8W

Plate Type:
Microtiter 96 Deepwell plate (95040450); KingFisher Flex 24 Deepwell plate (95040470)

Depth (English):
18.1 in.

Height (English):
13.4 in.

Weight (English):
37.5 lb.

Width (English):
15.7 in.

Description:
KingFisher Duo Prime

Cooling Temperature:
4° to 75°C in RT (elution strip)

Elution Strip:
Special design, 1 x 12 format

Heating Temperature:
10°C to 75°C in RT (plate row A)

Ports:
USB

Samples per Run:
Up to 12 (12-pin magnet head); Up to 6 (6-pin magnet head)

UV Exposure Time:
Up to 16 hr.

Memory:
Space for ca. 200 protocols

Protocol Import:
Using PC or USB memory device

Depth (Metric):
46 cm

Height (Metric):
34 cm

Weight (Metric):
17 kg

Width (Metric):
40 cm

Img

Fischer Scientific

14-387-71

--


Volume (Metric) Processing:
__

Collection Efficiency of Particles:
__

Display:
__

For Use With (Application):
__

Particle Size (Metric):
__

Quantity:
__

Type of Magnet Head:
__

UV Lamp:
__

Plate Type:
__

Depth (English):
__

Height (English):
__

Weight (English):
__

Width (English):
__

Description:
Finntip Flex 300, Non-Filtered, Sterile, Rack

Cooling Temperature:
__

Elution Strip:
__

Heating Temperature:
__

Ports:
__

Samples per Run:
__

UV Exposure Time:
__

Memory:
__

Protocol Import:
__

Depth (Metric):
__

Height (Metric):
__

Weight (Metric):
__

Width (Metric):
__

Img

Fischer Scientific

14-387-72

--


Volume (Metric) Processing:
__

Collection Efficiency of Particles:
__

Display:
__

For Use With (Application):
__

Particle Size (Metric):
__

Quantity:
__

Type of Magnet Head:
__

UV Lamp:
__

Plate Type:
__

Depth (English):
__

Height (English):
__

Weight (English):
__

Width (English):
__

Description:
Finntip Flex 300 refill starter kit, Non-Filtered, Non-sterile, Refill

Cooling Temperature:
__

Elution Strip:
__

Heating Temperature:
__

Ports:
__

Samples per Run:
__

UV Exposure Time:
__

Memory:
__

Protocol Import:
__

Depth (Metric):
__

Height (Metric):
__

Weight (Metric):
__

Width (Metric):
__

Img

Fischer Scientific

14-387-73

--


Volume (Metric) Processing:
__

Collection Efficiency of Particles:
__

Display:
__

For Use With (Application):
__

Particle Size (Metric):
__

Quantity:
__

Type of Magnet Head:
__

UV Lamp:
__

Plate Type:
__

Depth (English):
__

Height (English):
__

Weight (English):
__

Width (English):
__

Description:
Finntip Flex 300, Non-Filtered, Non-sterile, Refill

Cooling Temperature:
__

Elution Strip:
__

Heating Temperature:
__

Ports:
__

Samples per Run:
__

UV Exposure Time:
__

Memory:
__

Protocol Import:
__

Depth (Metric):
__

Height (Metric):
__

Weight (Metric):
__

Width (Metric):
__