43-233-06

Applied Biosystems™ TaqMan™ RNase P Instrument Verification Plate for 7900HT System, 384-well

Manufacturer: Applied Biosystems™

Select a Size

Pack Size SKU Availability Price
Each of 1 43-233-06-Each-of-1 In Stock ₹ 1,09,345.68

43-233-06 - Each of 1

₹ 1,09,345.68

In Stock

Quantity

1

Base Price: ₹ 1,09,345.68

GST (18%): ₹ 19,682.222

Total Price: ₹ 1,29,027.902

Content And Storage

Contains a 384-Well Reaction Plate pre-loaded and sealed with the 5’ nuclease assay using RNase P TaqMan™ probes and primers. Store at -15 to 25°C. Protect from light.

For Use With (Equipment)

AB 7900 HT 384-well System

Product Line

TaqMan™

For Use With (Application)

Real Time PCR (qPCR)

Description

For 384-well

Calibration Type

RNase P Calibration, Instrument Verification Plate

Calibrated Dye

FAM

Detection Method

Fluorescence

Product Type

Instrument Verification Plate

Shipping Condition

Dry Ice

Quantity

1 x 384-well Plate

Related Products

Img

Applied Biosystems™

43-109-82

--

Img

Applied Biosystems™

43-714-39

--

Img

Applied Biosystems™

43-505-84

--

Img

Applied Biosystems™

43-519-79

--

Img

Applied Biosystems™

44-552-80

--

Img

Applied Biosystems™

43-622-01

--

Img

Applied Biosystems™

43-511-51

--

Img

Applied Biosystems™

44-255-59

--

Description

  • The TaqMan™ RNase P 384-well Instrument Verification Plate is a 384-well PCR plate preloaded with the necessary reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme
  • Each well contains preloaded reaction mix (1X TaqMan™ Universal PCR Master Mix, RNase P primers, and FAM™ dye–labeled probe) and template.The TaqMan™ RNase P Instrument 384-well Instrument Verification Plate satisfies the same requirements as the Applied Biosystems™ 7900 HT Real-Time PCR Systems installation
  • To pass installation, the instruments must demonstrate the ability to distinguish between 5,000 and 10,000 genomic equivalents with a 99.7% confidence level for a subsequent sample run in a single well
  • To ensure accurate results, Applied Biosystems™ recommends that the performance of your instrument be verified every six months
  • For Research Use Only
  • Not for use in diagnostic procedures
  • Not intended for any animal or human therapeutic or diagnostic use.

Compare Similar Items

Show Difference

Img

Applied Biosystems™

43-233-06

--


Content And Storage:
Contains a 384-Well Reaction Plate pre-loaded and sealed with the 5’ nuclease assay using RNase P TaqMan™ probes and primers. Store at -15 to 25°C. Protect from light.

For Use With (Equipment):
AB 7900 HT 384-well System

Product Line:
TaqMan™

For Use With (Application):
Real Time PCR (qPCR)

Description:
For 384-well

Calibration Type:
RNase P Calibration, Instrument Verification Plate

Calibrated Dye:
FAM

Detection Method:
Fluorescence

Product Type:
Instrument Verification Plate

Shipping Condition:
Dry Ice

Quantity:
1 x 384-well Plate

Img

Fischer Scientific

43-240-18

--


Content And Storage:
Supplied at 2X concentration. The mix contains AmpliTaq Gold™ DNA Polymerase, dNTPs with dUTP, Passive Reference 1 and optimized buffer components. This pack contains one 5 mL tube, sufficient for 200 reactions at the 50 μL total volume. Store at 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

For Use With (Equipment):
7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode

Product Line:
TaqMan™

For Use With (Application):
Gene Expression, Genotyping, miRNA analysis

Description:
__

Calibration Type:
__

Calibrated Dye:
__

Detection Method:
Primer-probe

Product Type:
Universal PCR Master Mix

Shipping Condition:
Wet Ice

Quantity:
1 x 5 mL

Img

Fischer Scientific

43-240-20

--


Content And Storage:
Supplied at 2X concentration. The mix contains AmpliTaq Gold™ DNA Polymerase, dNTPs with dUTP, Passive Reference 1 and optimized buffer components. This pack contains 10 X 5 mL tubes, sufficient for 2000 reactions at the 50 μL total volume. Store at 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

For Use With (Equipment):
7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode

Product Line:
TaqMan™

For Use With (Application):
Gene Expression, Genotyping, miRNA analysis

Description:
__

Calibration Type:
__

Calibrated Dye:
__

Detection Method:
Primer-probe

Product Type:
Universal PCR Master Mix

Shipping Condition:
Wet Ice

Quantity:
10 x 5 mL

Img

LIFE TECHNOLOGIES

43-262-45

--


Content And Storage:
__

For Use With (Equipment):
__

Product Line:
__

For Use With (Application):
__

Description:
__

Calibration Type:
__

Calibrated Dye:
__

Detection Method:
__

Product Type:
__

Shipping Condition:
__

Quantity:
__