01-912-545

METTLER TOLEDO™ EasyPlus Easy KFV Titrator

Manufacturer: METTLER TOLEDO™

Select a Size

Pack Size SKU Availability Price
Each of 1 01-912-545-Each-of-1 In Stock ₹ 7,00,608.06

01-912-545 - Each of 1

₹ 7,00,608.06

In Stock

Quantity

1

Base Price: ₹ 7,00,608.06

GST (18%): ₹ 1,26,109.451

Total Price: ₹ 8,26,717.511

Burette Functions

EasyPlus burette 10 mL (included)

Accuracy (Temperature)

0.2°C

Blank Options

Variable or fixed value

Calibration Points

2

Connector Types

BNC, USB A, USB B, Mini-DIN, RCA

Data Management Details

Export via USB, USB Printer

Detection Range

100 ppm to 100%

Equivalence Points

Detection of up to 3

Includes

EM43-BNC sensor redox ipol, EasyPlus burette 10mL, EasyPlus tubing set instrument, EasyPlus tubing set EasyPump, EasyStir KF, EasyPlus titration head KF, EasyPlus drying tube, Valve, Bottle head, Insert set titration head KF, EasyPump, weighing boat

Keypad

Touchscreen

Material

PP GF30

Model

Easy KFV

Precision

0.5% RSD

Range (mV)

±2000 mV

Resolution

±0.1mV

Resolution (mV)

±0.1mV

Sample ID

None, Fixed, Variable

Stirrer Probe Speeds

Low, Medium, High, Maximum

Temperature (Metric) Operating

5 to 40°C

Temperature Range (Metric)

0 to 100°C

Temperature Selection

°C / °F

Titration Process Control

Normal, Fast, Cautious, Very cautious, User defined

Titration Types

Karl Fischer Volumetric

Volume (Metric) Sample

100 mL Beaker

Dimensions (L x W x H)

220 x 170 x 350 mm

Width (Metric)

170 mm

Depth (Metric)

220 mm

Voltage

100 to 240V ±10%

Accuracy (mV)

0.1

Backlight Option

Yes

Burette Sizes

10 mL (Standard Delivery), 20 mL, or 50 mL

Certifications/Compliance

CE, CSA

Cycles Per Titration Run

Maximum number of samples in a series is 5. When choosing this option the mean value and RSD is calculated.

Description

Easy KFV

Display Type

4.3 inch, 480 x 272 pixel RGB

For Use With (Application)

Determination of routine volumetric Karl Fischer titration in food, chemical products and other sample types

Inputs

BNC, USB A, USB B, Mini-DIN, RCA

Languages

15

Methods

Volumetric Karl Fischer

Power Supply

24 VDC / 1.25 A

Range (ISE)

±2000 mV

Relative Humidity Range

Max. 80% at 31°C

Resolution (ISE)

0.1 μA

Resolution (Temperature)

0.1°C

Sample Size

User Defined

Temperature (English) Operating

0°F to 212°F

Temperature Range (English) Ambient

41°F to 104°F

Temperature Range (Metric) Ambient

5°C to 40°C

Time and Date

Yes

Titration Setup Wizard

iTitrate

Updateable Firmware

Yes

Warranty

12 months

Width (English)

6.7 in.

Depth (English)

8.66 in.

Electrical Requirements

100 to 240V ±10% 50/60Hz

Frequency

50/60 Hz

Related Products

Img

METTLER TOLEDO™

01-915-012

--

Img

METTLER TOLEDO™

01-912-541

--

Img

METTLER TOLEDO™

01-912-544

--

Img

METTLER TOLEDO™

01-912-543

--

Img

METTLER TOLEDO™

13-940-090

--

Img

METTLER TOLEDO™

13-940-089

--

Img

METTLER TOLEDO™

01-912-565

--

Img

Fischer Scientific

7113366

Benefit from the integration of our...

Description

  • Test sample in range from 100ppm to 100% Designed and constructed by Swiss development team in accordance with highest software and hardware standards High quality components capable of enduring harsh laboratory conditions Built-in iTitrate™ intelligence requires few parameters to be set before titration Automatically calculate accurate, reproducible and repetable results which are stored and available for print or transfer to EasyDirect™ software using predefined formulas Sensor test helps to correct problem Smartphone-style Apps design is used to control all major instrument functions making it easy to use LongClick™ helps to start last analysis run without always navigating routine analyses Have EasySetup guides steps for installation and programming Simple and automatic titrant standardizations Have injection port for syringes and pipetted liquid samples Handy weighing/carrying spoon for easy and spill-free solid sample introduction Reduces training time with help of App style user interface while increasing work speed and simplicity Eliminate manual calculations and documentation with printer or Titration PC Software

Compare Similar Items

Show Difference

Img

METTLER TOLEDO™

01-912-545

--


Burette Functions:
EasyPlus burette 10 mL (included)

Accuracy (Temperature):
0.2°C

Blank Options:
Variable or fixed value

Calibration Points:
2

Connector Types:
BNC, USB A, USB B, Mini-DIN, RCA

Data Management Details:
Export via USB, USB Printer

Detection Range:
100 ppm to 100%

Equivalence Points:
Detection of up to 3

Includes:
EM43-BNC sensor redox ipol, EasyPlus burette 10mL, EasyPlus tubing set instrument, EasyPlus tubing set EasyPump, EasyStir KF, EasyPlus titration head KF, EasyPlus drying tube, Valve, Bottle head, Insert set titration head KF, EasyPump, weighing boat

Keypad:
Touchscreen

Material:
PP GF30

Model:
Easy KFV

Precision:
0.5% RSD

Range (mV):
±2000 mV

Resolution:
±0.1mV

Resolution (mV):
±0.1mV

Sample ID:
None, Fixed, Variable

Stirrer Probe Speeds:
Low, Medium, High, Maximum

Temperature (Metric) Operating:
5 to 40°C

Temperature Range (Metric):
0 to 100°C

Temperature Selection:
°C / °F

Titration Process Control:
Normal, Fast, Cautious, Very cautious, User defined

Titration Types:
Karl Fischer Volumetric

Volume (Metric) Sample:
100 mL Beaker

Dimensions (L x W x H):
220 x 170 x 350 mm

Width (Metric):
170 mm

Depth (Metric):
220 mm

Voltage:
100 to 240V ±10%

Accuracy (mV):
0.1

Backlight Option:
Yes

Burette Sizes:
10 mL (Standard Delivery), 20 mL, or 50 mL

Certifications/Compliance:
CE, CSA

Cycles Per Titration Run:
Maximum number of samples in a series is 5. When choosing this option the mean value and RSD is calculated.

Description:
Easy KFV

Display Type:
4.3 inch, 480 x 272 pixel RGB

For Use With (Application):
Determination of routine volumetric Karl Fischer titration in food, chemical products and other sample types

Inputs:
BNC, USB A, USB B, Mini-DIN, RCA

Methods:
Volumetric Karl Fischer

Power Supply:
24 VDC / 1.25 A

Range (ISE):
±2000 mV

Relative Humidity Range:
Max. 80% at 31°C

Resolution (ISE):
0.1 μA

Resolution (Temperature):
0.1°C

Sample Size:
User Defined

Temperature (English) Operating:
0°F to 212°F

Temperature Range (English) Ambient:
41°F to 104°F

Temperature Range (Metric) Ambient:
5°C to 40°C

Time and Date:
Yes

Titration Setup Wizard:
iTitrate

Updateable Firmware:
Yes

Warranty:
12 months

Width (English):
6.7 in.

Depth (English):
8.66 in.

Electrical Requirements:
100 to 240V ±10% 50/60Hz

Frequency:
50/60 Hz

Img

Mettler Toledo™

01-912-548

--


Burette Functions:
__

Accuracy (Temperature):
__

Blank Options:
__

Calibration Points:
__

Connector Types:
__

Data Management Details:
__

Detection Range:
__

Equivalence Points:
__

Includes:
__

Keypad:
__

Material:
__

Model:
__

Precision:
__

Range (mV):
__

Resolution:
__

Resolution (mV):
__

Sample ID:
__

Stirrer Probe Speeds:
__

Temperature (Metric) Operating:
__

Temperature Range (Metric):
__

Temperature Selection:
__

Titration Process Control:
__

Titration Types:
__

Volume (Metric) Sample:
__

Dimensions (L x W x H):
__

Width (Metric):
__

Depth (Metric):
__

Voltage:
__

Accuracy (mV):
__

Backlight Option:
__

Burette Sizes:
__

Certifications/Compliance:
__

Cycles Per Titration Run:
__

Description:
__

Display Type:
__

For Use With (Application):
__

Inputs:
__

Methods:
__

Power Supply:
__

Range (ISE):
__

Relative Humidity Range:
__

Resolution (ISE):
__

Resolution (Temperature):
__

Sample Size:
__

Temperature (English) Operating:
__

Temperature Range (English) Ambient:
__

Temperature Range (Metric) Ambient:
__

Time and Date:
__

Titration Setup Wizard:
__

Updateable Firmware:
__

Warranty:
__

Width (English):
__

Depth (English):
__

Electrical Requirements:
__

Frequency:
__

Img

Fischer Scientific

01-912-560

--


Burette Functions:
__

Accuracy (Temperature):
__

Blank Options:
__

Calibration Points:
__

Connector Types:
__

Data Management Details:
__

Detection Range:
__

Equivalence Points:
__

Includes:
__

Keypad:
__

Material:
__

Model:
__

Precision:
__

Range (mV):
__

Resolution:
__

Resolution (mV):
__

Sample ID:
__

Stirrer Probe Speeds:
__

Temperature (Metric) Operating:
__

Temperature Range (Metric):
__

Temperature Selection:
__

Titration Process Control:
__

Titration Types:
__

Volume (Metric) Sample:
__

Dimensions (L x W x H):
__

Width (Metric):
__

Depth (Metric):
__

Voltage:
__

Accuracy (mV):
__

Backlight Option:
__

Burette Sizes:
__

Certifications/Compliance:
__

Cycles Per Titration Run:
__

Description:
__

Display Type:
__

For Use With (Application):
__

Inputs:
__

Methods:
__

Power Supply:
__

Range (ISE):
__

Relative Humidity Range:
__

Resolution (ISE):
__

Resolution (Temperature):
__

Sample Size:
__

Temperature (English) Operating:
__

Temperature Range (English) Ambient:
__

Temperature Range (Metric) Ambient:
__

Time and Date:
__

Titration Setup Wizard:
__

Updateable Firmware:
__

Warranty:
__

Width (English):
__

Depth (English):
__

Electrical Requirements:
__

Frequency:
__

Img

Fischer Scientific

01-912-561

--


Burette Functions:
__

Accuracy (Temperature):
__

Blank Options:
__

Calibration Points:
__

Connector Types:
__

Data Management Details:
__

Detection Range:
__

Equivalence Points:
__

Includes:
__

Keypad:
__

Material:
__

Model:
__

Precision:
__

Range (mV):
__

Resolution:
__

Resolution (mV):
__

Sample ID:
__

Stirrer Probe Speeds:
__

Temperature (Metric) Operating:
__

Temperature Range (Metric):
__

Temperature Selection:
__

Titration Process Control:
__

Titration Types:
__

Volume (Metric) Sample:
__

Dimensions (L x W x H):
__

Width (Metric):
__

Depth (Metric):
__

Voltage:
__

Accuracy (mV):
__

Backlight Option:
__

Burette Sizes:
__

Certifications/Compliance:
__

Cycles Per Titration Run:
__

Description:
__

Display Type:
__

For Use With (Application):
__

Inputs:
__

Methods:
__

Power Supply:
__

Range (ISE):
__

Relative Humidity Range:
__

Resolution (ISE):
__

Resolution (Temperature):
__

Sample Size:
__

Temperature (English) Operating:
__

Temperature Range (English) Ambient:
__

Temperature Range (Metric) Ambient:
__

Time and Date:
__

Titration Setup Wizard:
__

Updateable Firmware:
__

Warranty:
__

Width (English):
__

Depth (English):
__

Electrical Requirements:
__

Frequency:
__