13-642-957

Thermo Scientific™ Orion Star T910 pH Titrator and Kits

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each 13-642-957-Each In Stock ₹ 3,98,337.41

13-642-957 - Each

₹ 3,98,337.41

In Stock

Quantity

1

Base Price: ₹ 3,98,337.41

GST (18%): ₹ 71,700.734

Total Price: ₹ 4,70,038.144

Accuracy (mV)

±0.2 mV

Functions Available

Sample titration, titrant standardization, calibration and direct measure

Accuracy (Temperature)

±0.2 °C

Backlight Option

Yes, adjustable

Burette Sizes

10 mL, 20 mL (included) or 50 mL

Calibration Points (pH)

1 to 5

Channels

1

Data Management Details

Data log export as CSV or PDF file, short or long format

Description

Orion Star T910 pH titrator ROSS Sure-Flow kit

Type

Acid/base titrator

For Use With (Application)

Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)

Inputs

BNC (pH electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Languages

Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish

Memory

Non-volatile memory preserves data logs and settings

Model

Orion Star T910

Precision

0.5% RSD, dependent on environment and handling conditions

Probe Type

pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe

Range (pH)

-2 to 20

Resolution

Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)

Resolution (pH)

0.001, 0.01, 0.1 (user selectable)

Sample ID

Auto-incremental, manual or off

Temperature (English) Operating

41°F to 104°F

Temperature Probe Calibration

Optional 1 point offset calibration

Temperature Selection

Manual or automatic

Titrant Determination

Standardization titration or manual concentration input

Titration Setup Wizard

Yes, using Start a New Titration workflow

Titration Types

Direct or back titration

Warranty

1 year replacement warranty

Electrical Requirements

100-240V, 50/60 Hz

Burette Functions

Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc

Accuracy (pH)

±0.002pH

Alarm Output

Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder

Blank Options

Fixed value or variable value using titration

Calibration

pH and temperature

Certifications/Compliance

CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010

Cycles Per Titration Run

1 to 5 cycles, option to exclude cycle results from average results and RSD calculations

Data Points

100 data sets each: sample titration, titrant standardization, calibration and direct measure

Display Type

5.7” color capacitive touchscreen, 640 x 480 resolution

Equivalence Points

1 to 2

Includes

8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies

IP Rating

IP-51

Material

ABS Plastic

Methods

Up to 10 methods with optional password protection; import/export methods via USB flash drive

Outputs

3 USB ports for printer, USB flash drive and computer software connections

Preset Endpoints

1 to 3

Range (mV)

-2000.0 to +2000.0 mV

Relative Humidity Range

5 to 85%, non-condensing

Resolution (mV)

0.1 mV

Resolution (Temperature)

0.1 °C

Stirrer Probe Speeds

5 user selectable speeds (250 to 3700 RPM)

Temperature (Metric) Operating

5°C to 40°C

Temperature Range (Metric)

-5.0°C to +100.0°C

Time and Date

Yes, with nonvolatile battery backup

Titration Process Control

Routine, quick, careful or user defined

Titration Technique

Equivalence point or preset endpoint

Updateable Firmware

Yes, using USB flash drive

Dimensions (L x W x H)

10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm

Related Products

Img

Fischer Scientific

13-642-956

--

Img

Fischer Scientific

13-642-955

--

Img

Fischer Scientific

7113366

Benefit from the integration of our...

Img

Fischer Scientific

13-642-958

--

Img

Fischer Scientific

13-642-959

--

Img

Fischer Scientific

13-642-969

--

Img

Fischer Scientific

13-642-968

--

Img

Fischer Scientific

13-642-961

--

Description

  • Use the Orion Star T910 pH titrator for dedicated acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
  • Titration techniques include equivalence point titrations and preset pH endpoint titrations for versatile sample analysis
  • Pair the titrator option with any of our premium ROSS pH electrodes or select one of our preconfigured titrator and electrode kits for a bundled discount
  • Accurate, reproducible results: Automating the titration workflow enables analysis to be run using the same setup parameters and calculations every time Faster setup time: Setup and save electrode, titrant and titration parameters once using methods Improved lab throughput: Start the titration and let the instrument run unattended Reduced cost and downtime: Easily replace titrator parts to minimize maintenance downtime while long lasting electrodes reduce the cost of ownership Securely document test results: View results live, in the summary table and within the 100 point data log Applications database: Tested and validated preprogrammed methods can be loaded onto your titrator Standard ROSS kit with 8102BNUWP ROSS Ultra pH electrode and 927007MD stainless steel ATC temperature probe is ideal for most standard pH titrations and especially preset endpoint titrations that include temperature ROSS Sure-Flow kit with 8172BNWP ROSS Sure-Flow pH electrode is designed for challenging samples that can clog standard pH electrodes or that require a fast-flowing sleeve-type junction

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-642-957

--


Accuracy (mV):
±0.2 mV

Functions Available:
Sample titration, titrant standardization, calibration and direct measure

Accuracy (Temperature):
±0.2 °C

Backlight Option:
Yes, adjustable

Burette Sizes:
10 mL, 20 mL (included) or 50 mL

Calibration Points (pH):
1 to 5

Channels:
1

Data Management Details:
Data log export as CSV or PDF file, short or long format

Description:
Orion Star T910 pH titrator ROSS Sure-Flow kit

Type:
Acid/base titrator

For Use With (Application):
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)

Inputs:
BNC (pH electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Memory:
Non-volatile memory preserves data logs and settings

Model:
Orion Star T910

Precision:
0.5% RSD, dependent on environment and handling conditions

Probe Type:
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe

Range (pH):
-2 to 20

Resolution:
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)

Resolution (pH):
0.001, 0.01, 0.1 (user selectable)

Sample ID:
Auto-incremental, manual or off

Temperature (English) Operating:
41°F to 104°F

Temperature Probe Calibration:
Optional 1 point offset calibration

Temperature Selection:
Manual or automatic

Titrant Determination:
Standardization titration or manual concentration input

Titration Setup Wizard:
Yes, using Start a New Titration workflow

Titration Types:
Direct or back titration

Warranty:
1 year replacement warranty

Electrical Requirements:
100-240V, 50/60 Hz

Burette Functions:
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc

Accuracy (pH):
±0.002pH

Alarm Output:
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder

Blank Options:
Fixed value or variable value using titration

Calibration:
pH and temperature

Certifications/Compliance:
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010

Cycles Per Titration Run:
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations

Data Points:
100 data sets each: sample titration, titrant standardization, calibration and direct measure

Display Type:
5.7” color capacitive touchscreen, 640 x 480 resolution

Equivalence Points:
1 to 2

Includes:
8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies

IP Rating:
IP-51

Material:
ABS Plastic

Methods:
Up to 10 methods with optional password protection; import/export methods via USB flash drive

Outputs:
3 USB ports for printer, USB flash drive and computer software connections

Preset Endpoints:
1 to 3

Range (mV):
-2000.0 to +2000.0 mV

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (mV):
0.1 mV

Resolution (Temperature):
0.1 °C

Stirrer Probe Speeds:
5 user selectable speeds (250 to 3700 RPM)

Temperature (Metric) Operating:
5°C to 40°C

Temperature Range (Metric):
-5.0°C to +100.0°C

Time and Date:
Yes, with nonvolatile battery backup

Titration Process Control:
Routine, quick, careful or user defined

Titration Technique:
Equivalence point or preset endpoint

Updateable Firmware:
Yes, using USB flash drive

Dimensions (L x W x H):
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm

Img

Fischer Scientific

13-642-958

--


Accuracy (mV):
±0.2 mV

Functions Available:
Sample titration, titrant standardization, calibration and direct measure

Accuracy (Temperature):
±0.2 °C

Backlight Option:
Yes, adjustable

Burette Sizes:
10 mL, 20 mL (included) or 50 mL

Calibration Points (pH):
__

Channels:
1

Data Management Details:
Data log export as CSV or PDF file, short or long format

Description:
Orion Star T920 redox titrator without electrode

Type:
Redox titrator

For Use With (Application):
Redox titrations including sulfite/SO2 and reducing sugar in juice and wine, ascorbic acid (vitamin C) and peroxide value in food products, dissolved oxygen in wastewater by Winkler titration and organic matter in soil

Inputs:
BNC (redox/ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Memory:
Non-volatile memory preserves data logs and settings

Model:
Orion Star T920

Precision:
0.5% RSD, dependent on environment and handling conditions

Probe Type:
Redox/ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe

Range (pH):
__

Resolution:
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)

Resolution (pH):
__

Sample ID:
Auto-incremental, manual or off

Temperature (English) Operating:
41°F to 104°F

Temperature Probe Calibration:
Optional 1 point offset calibration

Temperature Selection:
Manual or automatic

Titrant Determination:
Standardization titration or manual concentration input

Titration Setup Wizard:
Yes, using Start a New Titration workflow

Titration Types:
Direct or back titration

Warranty:
1 year replacement warranty

Electrical Requirements:
100-240V, 50/60 Hz

Burette Functions:
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc

Accuracy (pH):
__

Alarm Output:
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder

Blank Options:
Fixed value or variable value using titration

Calibration:
mV and temperature

Certifications/Compliance:
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010

Cycles Per Titration Run:
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations

Data Points:
100 data sets each: sample titration, titrant standardization, calibration and direct measure

Display Type:
5.7” color capacitive touchscreen, 640 x 480 resolution

Equivalence Points:
1 to 2

Includes:
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies

IP Rating:
IP-51

Material:
ABS Plastic

Methods:
Up to 10 methods with optional password protection; import/export methods via USB flash drive

Outputs:
3 USB ports for printer, USB flash drive and computer software connections

Preset Endpoints:
1 to 3

Range (mV):
-2000.0 to +2000.0 mV

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (mV):
0.1 mV

Resolution (Temperature):
0.1 °C

Stirrer Probe Speeds:
5 user selectable speeds (250 to 3700 RPM)

Temperature (Metric) Operating:
5°C to 40°C

Temperature Range (Metric):
-5.0°C to +100.0°C

Time and Date:
Yes, with nonvolatile battery backup

Titration Process Control:
Routine, quick, careful or user defined

Titration Technique:
Equivalence point or preset endpoint

Updateable Firmware:
Yes, using USB flash drive

Dimensions (L x W x H):
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm

Img

Fischer Scientific

13-642-959

--


Accuracy (mV):
±0.2 mV

Functions Available:
Sample titration, titrant standardization, calibration and direct measure

Accuracy (Temperature):
±0.2 °C

Backlight Option:
Yes, adjustable

Burette Sizes:
10 mL, 20 mL (included) or 50 mL

Calibration Points (pH):
__

Channels:
1

Data Management Details:
Data log export as CSV or PDF file, short or long format

Description:
Orion Star T920 redox titrator standard kit

Type:
Redox titrator

For Use With (Application):
Redox titrations including sulfite/SO2 and reducing sugar in juice and wine, ascorbic acid (vitamin C) and peroxide value in food products, dissolved oxygen in wastewater by Winkler titration and organic matter in soil

Inputs:
BNC (redox/ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Memory:
Non-volatile memory preserves data logs and settings

Model:
Orion Star T920

Precision:
0.5% RSD, dependent on environment and handling conditions

Probe Type:
Redox/ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe

Range (pH):
__

Resolution:
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)

Resolution (pH):
__

Sample ID:
Auto-incremental, manual or off

Temperature (English) Operating:
41°F to 104°F

Temperature Probe Calibration:
Optional 1 point offset calibration

Temperature Selection:
Manual or automatic

Titrant Determination:
Standardization titration or manual concentration input

Titration Setup Wizard:
Yes, using Start a New Titration workflow

Titration Types:
Direct or back titration

Warranty:
1 year replacement warranty

Electrical Requirements:
100-240V, 50/60 Hz

Burette Functions:
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc

Accuracy (pH):
__

Alarm Output:
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder

Blank Options:
Fixed value or variable value using titration

Calibration:
mV and temperature

Certifications/Compliance:
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010

Cycles Per Titration Run:
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations

Data Points:
100 data sets each: sample titration, titrant standardization, calibration and direct measure

Display Type:
5.7” color capacitive touchscreen, 640 x 480 resolution

Equivalence Points:
1 to 2

Includes:
9778BNWP glass-body redox electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies

IP Rating:
IP-51

Material:
ABS Plastic

Methods:
Up to 10 methods with optional password protection; import/export methods via USB flash drive

Outputs:
3 USB ports for printer, USB flash drive and computer software connections

Preset Endpoints:
1 to 3

Range (mV):
-2000.0 to +2000.0 mV

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (mV):
0.1 mV

Resolution (Temperature):
0.1 °C

Stirrer Probe Speeds:
5 user selectable speeds (250 to 3700 RPM)

Temperature (Metric) Operating:
5°C to 40°C

Temperature Range (Metric):
-5.0°C to +100.0°C

Time and Date:
Yes, with nonvolatile battery backup

Titration Process Control:
Routine, quick, careful or user defined

Titration Technique:
Equivalence point or preset endpoint

Updateable Firmware:
Yes, using USB flash drive

Dimensions (L x W x H):
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm

Img

Fischer Scientific

13-642-960

--


Accuracy (mV):
±0.2 mV

Functions Available:
Sample titration, titrant standardization, calibration and direct measure

Accuracy (Temperature):
±0.2 °C

Backlight Option:
Yes, adjustable

Burette Sizes:
10 mL, 20 mL (included) or 50 mL

Calibration Points (pH):
__

Channels:
1

Data Management Details:
Data log export as CSV or PDF file, short or long format

Description:
Orion Star T930 ion titrator without electrode

Type:
Ion titrator

For Use With (Application):
Ion concentration titrations including salt in food products, calcium in juice and milk, total hardness of drinking water and wastewater, chloride in drinking water and wastewater, ammonia and Total Kjeldahl Nitrogen (TKN) of wastewater and surfactants in consumer products

Inputs:
BNC (ion selective electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)

Memory:
Non-volatile memory preserves data logs and settings

Model:
Orion Star T930

Precision:
0.5% RSD, dependent on environment and handling conditions

Probe Type:
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe

Range (pH):
__

Resolution:
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)

Resolution (pH):
__

Sample ID:
Auto-incremental, manual or off

Temperature (English) Operating:
41°F to 104°F

Temperature Probe Calibration:
Optional 1 point offset calibration

Temperature Selection:
Manual or automatic

Titrant Determination:
Standardization titration or manual concentration input

Titration Setup Wizard:
Yes, using Start a New Titration workflow

Titration Types:
Direct or back titration

Warranty:
1 year replacement warranty

Electrical Requirements:
100-240V, 50/60 Hz

Burette Functions:
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc

Accuracy (pH):
__

Alarm Output:
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder

Blank Options:
Fixed value or variable value using titration

Calibration:
Ion concentration (ISE) and temperature

Certifications/Compliance:
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010

Cycles Per Titration Run:
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations

Data Points:
100 data sets each: sample titration, titrant standardization, calibration and direct measure

Display Type:
5.7” color capacitive touchscreen, 640 x 480 resolution

Equivalence Points:
1 to 2

Includes:
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies

IP Rating:
IP-51

Material:
ABS Plastic

Methods:
Up to 10 methods with optional password protection; import/export methods via USB flash drive

Outputs:
3 USB ports for printer, USB flash drive and computer software connections

Preset Endpoints:
1 to 3

Range (mV):
-2000.0 to +2000.0 mV

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (mV):
0.1 mV

Resolution (Temperature):
0.1 °C

Stirrer Probe Speeds:
5 user selectable speeds (250 to 3700 RPM)

Temperature (Metric) Operating:
5°C to 40°C

Temperature Range (Metric):
-5.0°C to +100.0°C

Time and Date:
Yes, with nonvolatile battery backup

Titration Process Control:
Routine, quick, careful or user defined

Titration Technique:
Equivalence point or preset endpoint

Updateable Firmware:
Yes, using USB flash drive

Dimensions (L x W x H):
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm