01-912-352

Mettler Toledo™ FiveEasy™ F30 Conductivity Meters

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 01-912-352-Each-of-1 In Stock ₹ 90,693.60

01-912-352 - Each of 1

₹ 90,693.60

In Stock

Quantity

1

Base Price: ₹ 90,693.60

GST (18%): ₹ 16,324.848

Total Price: ₹ 1,07,018.448

Description

FiveEasy F30-Basic

Includes

F30 pH meter, electrode holder, 1 each buffers 1413mS/cm and 12.88mS/cm standard sachets, test certificate

Calibration

One point calibration with three predefined standards

Resolution (Conductivity)

Automatic range

Temperature Range (English)

32°F to 212°F

Accuracy (Temperature)

0.5°C

Inputs

Mini-DIN

Weight (Metric)

0.63 kg

Type

F30 Meter Only

Frequency

50/60Hz

Accuracy (Conductivity)

±0.5% of the measured value

For Use With (Application)

Applications that require a specific sensor not included in a kit

Range (Conductivity)

0.01 μS/cm to 200 mS/cm

Temperature Compensation

Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C

Resolution (Temperature)

0.1°C

Memory

Current calibration

Dimensions (L x W x H)

22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.)

Weight (English)

1.4 lb.

Voltage

100/240V

Related Products

Img

Fischer Scientific

01-912-354

--

Img

Fischer Scientific

01-912-353

--

Img

Fischer Scientific

01-912-355

--

Img

Fischer Scientific

7070338

Compact, benchtop meter provides hi...

Img

Fischer Scientific

7070337

Compact, benchtop meter provides hi...

Img

Fischer Scientific

01-912-360

--

Img

Fischer Scientific

01-912-361

--

Img

Fischer Scientific

01-912-362

--

Description

  • Compact, space saving design with ABS housing Remove sensor holder after use and store on the side of the meter Large, well-structured 4.3 in
  • segmented LCD display for easy viewing Intuitive button arrangement and simple menu for easy operation One point calibration with three predefined standards Mini-DIN sensor input Features Automatic and manual endpoint recording, Acoustic endpoint signal, Visual endpoint signal Ideal for wide range of laboratory applications Specifications: Conductivity Range: 0.01μS/cm to 200mS/cm Conductivity Resolution: Automatic range Conductivity Accuracy: ±0.5% of the measured value TDS Range: 0.01mg/L to 200g/L TDS Resolution: Automatic range TDS Accuracy: ±0.5% of the measured value Temperature Range: 0° to 100°C (32° to 212°F) Temperature Resolution: 0.1°C Temperature Accuracy: 0.5°C Temperature Compensation: Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C Memory Size: current calibration Power Supply: 100 to 240V, 50/60Hz, 12 VDC Dimensions: 22.7 x 14.7 x 7cm (9 x 5.7 x 2.7 in.) Weight: 0.63kg (1.4 lb.) Applications: F30 Meter only: Suited for applications that require a specific sensor not included in a kit F30 Standard Kit: Suited for aqueous samples with mid to high conductivity

Compare Similar Items

Show Difference

Img

Fischer Scientific

01-912-352

--


Description:
FiveEasy F30-Basic

Includes:
F30 pH meter, electrode holder, 1 each buffers 1413mS/cm and 12.88mS/cm standard sachets, test certificate

Calibration:
One point calibration with three predefined standards

Resolution (Conductivity):
Automatic range

Temperature Range (English):
32°F to 212°F

Accuracy (Temperature):
0.5°C

Inputs:
Mini-DIN

Weight (Metric):
0.63 kg

Type:
F30 Meter Only

Frequency:
50/60Hz

Accuracy (Conductivity):
±0.5% of the measured value

For Use With (Application):
Applications that require a specific sensor not included in a kit

Range (Conductivity):
0.01 μS/cm to 200 mS/cm

Temperature Compensation:
Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C

Resolution (Temperature):
0.1°C

Memory:
Current calibration

Dimensions (L x W x H):
22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.)

Weight (English):
1.4 lb.

Voltage:
100/240V

Img

Fischer Scientific

01-912-353

--


Description:
FiveEasy F30-Std

Includes:
F30 pH meter, LE703 pH sensor, electrode holder, 1 each buffers 1413mS/cm and 12.88mS/cm standard sachets, test certificate

Calibration:
One point calibration with three predefined standards

Resolution (Conductivity):
Automatic range

Temperature Range (English):
32°F to 212°F

Accuracy (Temperature):
0.5°C

Inputs:
Mini-DIN

Weight (Metric):
0.63 kg

Type:
F30 Standard Kit

Frequency:
50/60Hz

Accuracy (Conductivity):
±0.5% of the measured value

For Use With (Application):
Suited for aqueous samples with mid to high conductivity

Range (Conductivity):
0.01 μS/cm to 200 mS/cm

Temperature Compensation:
Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C

Resolution (Temperature):
0.1°C

Memory:
Current calibration

Dimensions (L x W x H):
22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.)

Weight (English):
1.4 lb.

Voltage:
100/240V

Img

Fischer Scientific

01-912-354

--


Description:
FiveEasy Plus FP30-Basic

Includes:
FP30 Meter, electrode holder, 2 buffer sachets each for pH 1413 mS/cm and 12.88 mS/cm), test certificate

Calibration:
One point calibration with three predefined standards, manual cell constant input

Resolution (Conductivity):
Automatic range

Temperature Range (English):
32°F to 212°F

Accuracy (Temperature):
0.3°C

Inputs:
Mini-DIN

Weight (Metric):
0.63 kg

Type:
FP30 Meter Only

Frequency:
50/60Hz

Accuracy (Conductivity):
±0.5% of the measured value

For Use With (Application):
Applications that require a specific sensor not included in a kit

Range (Conductivity):
0.01 μS/cm to 500 mS/cm

Temperature Compensation:
Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C

Resolution (Temperature):
0.1°C

Memory:
200 measurements, current calibration

Dimensions (L x W x H):
22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.)

Weight (English):
1.4 lb.

Voltage:
100/240V

Img

Fischer Scientific

01-912-355

--


Description:
FiveEasy Plus FP30-Std

Includes:
FP30 Meter, LE703 pH sensor, electrode holder, 2 buffer sachets each for pH 1413 mS/cm and 12.88 mS/cm), test certificate

Calibration:
One point calibration with three predefined standards, manual cell constant input

Resolution (Conductivity):
Automatic range

Temperature Range (English):
32°F to 212°F

Accuracy (Temperature):
0.3°C

Inputs:
Mini-DIN

Weight (Metric):
0.63 kg

Type:
FP30 Standard Kit

Frequency:
50/60Hz

Accuracy (Conductivity):
±0.5% of the measured value

For Use With (Application):
Suited for aqueous samples with mid to high conductivity

Range (Conductivity):
0.01 μS/cm to 500 mS/cm

Temperature Compensation:
Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C

Resolution (Temperature):
0.1°C

Memory:
200 measurements, current calibration

Dimensions (L x W x H):
22.7 x 14.7 x 7 cm (9 x 5.7 x 2.7 in.)

Weight (English):
1.4 lb.

Voltage:
100/240V