01-911-557

Mettler Toledo™ pH Plug and Play Glass Titration Electrodes

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 01-911-557-Each-of-1 In Stock ₹ 67,113.26

01-911-557 - Each of 1

₹ 67,113.26

In Stock

Quantity

1

Base Price: ₹ 67,113.26

GST (18%): ₹ 12,080.387

Total Price: ₹ 79,193.647

Connector Types

MultiPin, S12 (DGi115-SC), S7 (DG115-SC)

Material

Glass

Temperature (Metric) Operating

0°C to 100°C

Filling Solution Type

3mol/L KCl

Includes

Fixed sleeve diaphragm, for acid/base aqueous titration

Membrane

HA Glass

Temperature (English) Operating

32°F to 212°F

Length (English)

5.88 in.

Diameter (English)

0.47 in.

Junction

Ground Glass

pH Range

0 to 14

Type

pH Plug and Play Electrode

For Use With (Application)

For direct pH measurements and acid/base titrations

Internal Reference

ARGENTHAL

Model

DGi115-SC

Temperature (Metric) Range

0°C to 100°C

Length (Metric)

149.5 mm

Diameter (Metric)

12 mm

Related Products

Img

Fischer Scientific

01-911-566

--

Img

Fischer Scientific

01-911-556

--

Img

Fischer Scientific

01-910-722

--

Img

Fischer Scientific

01-911-558

--

Img

Fischer Scientific

01-911-555

--

Img

Fischer Scientific

01-911-559

--

Img

Fischer Scientific

01-911-458

--

Img

Fischer Scientific

01-911-450

--

Description

  • ARGENTHAL™ reference system present Features refillable reference electrolyte Shaft material is made of glass Length, 150mm; Diameter, 12mm Model DGi101-SC and DGi102-Mini U-glass type membrane glass Diaphragm is ceramic pin Silver ion trap to ensure that the electrolyte is absolutely free from silver ions DGi111-SC HA-taped type membrane glass Diaphragm is ceramic pin Silver ion trap to ensure that the electrolyte is absolutely free from silver ions DGi113-SC A41 cylindrical type membrane glass Movable PTFE sleeve junction Integrated glass sleeve for secure fixation in the titration head DGi115-SC HA-cylindrical type membrane glass Fixed ground glass sleeve junction Silver ion trap to ensure that the electrolyte is absolutely free from silver ions DGi114-SC HA-cylindrical type membrane glass Movable PTFE sleeve junction DGi116-Solvent Spherical A41 glass membrane of low resistance for fast and sensitive pH response and chemical resistance Easy-to-clean glass sleeve junction providing a uniform electrolyte flow Gold shielding for efficient electric and static shielding Movable ground glass sleeve junction DGi117-Water Double junction construction Fixed ground-glass sleeve junction Features Pt1000 temperature sensor Integrated glass sleeve for secure fixation in the titration head Gold shielding against electrostatic effects LoT spherical type membrane glass Spherical glass membrane of low resistance MultiPin™ screw cap for secure connection of combined electrode and temperature probe cable

Compare Similar Items

Show Difference

Img

Fischer Scientific

01-911-557

--


Connector Types:
MultiPin, S12 (DGi115-SC), S7 (DG115-SC)

Material:
Glass

Temperature (Metric) Operating:
0°C to 100°C

Filling Solution Type:
3mol/L KCl

Includes:
Fixed sleeve diaphragm, for acid/base aqueous titration

Membrane:
HA Glass

Temperature (English) Operating:
32°F to 212°F

Length (English):
5.88 in.

Diameter (English):
0.47 in.

Junction:
Ground Glass

pH Range:
0 to 14

Type:
pH Plug and Play Electrode

For Use With (Application):
For direct pH measurements and acid/base titrations

Internal Reference:
ARGENTHAL

Model:
DGi115-SC

Temperature (Metric) Range:
0°C to 100°C

Length (Metric):
149.5 mm

Diameter (Metric):
12 mm

Img

Fischer Scientific

01-911-558

--


Connector Types:
S12

Material:
Glass

Temperature (Metric) Operating:
0°C to 60°C

Filling Solution Type:
LiCl, 1mol/L in ethanol

Includes:
Moveable sleeve junction, for nonaqueous media

Membrane:
A41 Glass

Temperature (English) Operating:
32°F to 140°F

Length (English):
5.88 in.

Diameter (English):
0.47 in.

Junction:
Ground Glass

pH Range:
0 to 12

Type:
pH Plug and Play Electrode

For Use With (Application):
For direct pH measurements and acid/base titrations

Internal Reference:
ARGENTHAL/LiCl

Model:
DGi116-Solvent

Temperature (Metric) Range:
0°C to 100°C

Length (Metric):
149.5 mm

Diameter (Metric):
12 mm

Img

Fischer Scientific

01-911-559

--


Connector Types:
S12

Material:
Glass

Temperature (Metric) Operating:
0°C to 100°C

Filling Solution Type:
KCl gel internal, 1mol/L KCl bridge

Includes:
Integrated temperature sensor, for aqueous media

Membrane:
LoT Glass

Temperature (English) Operating:
32°F to 212°F

Length (English):
7.28 in.

Diameter (English):
0.47 in.

Junction:
Ground Glass External, Ceramic Pin Internal

pH Range:
1 to 11

Type:
pH Plug and Play Electrode

For Use With (Application):
For direct pH measurements and acid/base titrations

Internal Reference:
ARGENTHAL

Model:
DGi117-Water

Temperature (Metric) Range:
0°C to 100°C

Length (Metric):
185.1 mm

Diameter (Metric):
12 mm

Img

Fischer Scientific

01-911-560

--


Connector Types:
S12, S7

Material:
__

Temperature (Metric) Operating:
__

Filling Solution Type:
__

Includes:
__

Membrane:
__

Temperature (English) Operating:
__

Length (English):
5.8 in.

Diameter (English):
0.47 in.

Junction:
Ceramic Frit

pH Range:
__

Type:
Electrode

For Use With (Application):
__

Internal Reference:
ARGENTHAL™

Model:
__

Temperature (Metric) Range:
0°C to 80°C

Length (Metric):
149.5 mm

Diameter (Metric):
12 mm