01-915-108

METTLER TOLEDO™ InLab™ Expert pH Electrodes

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 01-915-108-Each-of-1 In Stock ₹ 49,881.48

01-915-108 - Each of 1

₹ 49,881.48

In Stock

Quantity

1

Base Price: ₹ 49,881.48

GST (18%): ₹ 8,978.666

Total Price: ₹ 58,860.146

Connector Types

BNC/RCA

Material

PEEK

Temperature (Metric) Operating

0°C to 100°C

Filling Solution Type

Xerolyt Polymer

For Use With (Equipment)

Fixed Cable to sensor

Membrane

U Glass

Probe

NTC 30 kilohm

Temperature (English) Operating

32°F to 212°F

Length (English)

4.7 in.

Length (Metric)

120 mm

Diameter (English)

0.47 in.

Junction

Open

pH Range

0 to 14

Type

Combination Electrode, Integrated Temperature Probe, Intelligent Sensor Management (ISM) Technology

For Use With (Application)

Emulsions, suspensions, effluent water and solutions containing Proteins and Sulphides

Internal Reference

ARGENTHAL

Model

InLab™ Expert Pro-ISM

Response Time

<20 sec.

Temperature (Metric) Range

0°C to 100°C

Length (English) Cable

47.2 in.

Length (Metric) Cable

1.2 m

Diameter (Metric)

12 mm

Related Products

Img

Fischer Scientific

01-911-465

--

Img

Fischer Scientific

01-911-461

--

Img

Fischer Scientific

01-910-552

--

Img

Fischer Scientific

01-917-140

--

Img

Fischer Scientific

01-911-463

--

Img

Fischer Scientific

01-917-141

--

Img

METTLER TOLEDO™

01-911-251

--

Img

Fischer Scientific

01-911-464

--

Description

  • Ideal for critical samples such as suspensions or samples of unknown composition
  • Mettler Toledo Expert Series pH and pH/ATC Combination Electrodes with open junction puts the reference electrode in direct contact with the measured medium, eliminating the possibility of contamination or blockage
  • For use with METTLER TOLEDO SevenExcellence, SevenCompact and portable meters as well as other brands
  • Connection cables may be required
  • Features a PEEK plastic shaft for harsh environments and requires no maintenance Intelligent Sensor Management (ISM) electrodes capture and save calibration data, which is then automatically recognized by the meter once connected
  • Capture electrode calibration and results with LabX software, designed for advanced data management and 21CFR part 11 regulatory compliance
  • Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples
  • Featured Applications General Lab Beverages Waste water Suspended solids Environmental TRIS compatible Accessories & Care Open Junction and non-refillable - no additional electrolyte required Store in 3M KCl (51350072) or InLab Storage Solution (30111142) Recommended for use with METTLER TOLEDO buffers (Sachets: 51302080, Bottles: 63056116)

Compare Similar Items

Show Difference

Img

Fischer Scientific

01-915-108

--


Connector Types:
BNC/RCA

Material:
PEEK

Temperature (Metric) Operating:
0°C to 100°C

Filling Solution Type:
Xerolyt Polymer

For Use With (Equipment):
Fixed Cable to sensor

Membrane:
U Glass

Probe:
NTC 30 kilohm

Temperature (English) Operating:
32°F to 212°F

Length (English):
4.7 in.

Length (Metric):
120 mm

Diameter (English):
0.47 in.

Junction:
Open

pH Range:
0 to 14

Type:
Combination Electrode, Integrated Temperature Probe, Intelligent Sensor Management (ISM) Technology

For Use With (Application):
Emulsions, suspensions, effluent water and solutions containing Proteins and Sulphides

Internal Reference:
ARGENTHAL

Model:
InLab™ Expert Pro-ISM

Response Time:
<20 sec.

Temperature (Metric) Range:
0°C to 100°C

Length (English) Cable:
47.2 in.

Length (Metric) Cable:
1.2 m

Diameter (Metric):
12 mm

Img

Fischer Scientific

01-915-110

--


Connector Types:
Mini-DIN

Material:
Epoxy, Graphite

Temperature (Metric) Operating:
__

Filling Solution Type:
__

For Use With (Equipment):
S230 SevenCompact conductivity meter

Membrane:
__

Probe:
Conductivity

Temperature (English) Operating:
__

Length (English):
4.72 in.

Length (Metric):
120 mm

Diameter (English):
__

Junction:
__

pH Range:
__

Type:
__

For Use With (Application):
General conductivity measurements

Internal Reference:
__

Model:
InLab™ 731-ISM

Response Time:
__

Temperature (Metric) Range:
0°C to 100°C

Length (English) Cable:
47.22 in.

Length (Metric) Cable:
1.2 m

Diameter (Metric):
__

Img

Fischer Scientific

01-915-111

--


Connector Types:
Mini-DIN

Material:
Epoxy, Graphite

Temperature (Metric) Operating:
__

Filling Solution Type:
__

For Use With (Equipment):
S230 SevenCompact conductivity meter

Membrane:
__

Probe:
Conductivity

Temperature (English) Operating:
__

Length (English):
4.72 in.

Length (Metric):
120 mm

Diameter (English):
__

Junction:
__

pH Range:
__

Type:
__

For Use With (Application):
General conductivity measurements

Internal Reference:
__

Model:
InLab™ 731-2m-ISM

Response Time:
__

Temperature (Metric) Range:
0°C to 100°C

Length (English) Cable:
78.7 in.

Length (Metric) Cable:
2 m

Diameter (Metric):
__

Img

Fischer Scientific

01-915-112

--


Connector Types:
Mini-DIN

Material:
Stainless Steel

Temperature (Metric) Operating:
__

Filling Solution Type:
__

For Use With (Equipment):
S230 SevenCompact conductivity meter

Membrane:
__

Probe:
Conductivity

Temperature (English) Operating:
__

Length (English):
4.72 in.

Length (Metric):
120 mm

Diameter (English):
__

Junction:
__

pH Range:
__

Type:
__

For Use With (Application):
General conductivity measurements

Internal Reference:
__

Model:
InLab™ 741-ISM

Response Time:
__

Temperature (Metric) Range:
0°C to 100°C

Length (English) Cable:
47.22 in.

Length (Metric) Cable:
1.2 m

Diameter (Metric):
__