13-642-675PMO

Thermo Scientific™ Orion™ ROSS Ultra™ Low Maintenance pH/ATC Triode™ Combination Electrodes PROMO

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Description

Orion ROSS Ultra Low Maintenance pH/ATC Triode Combination Electrodes with a BNC and RCA Connector and 1 meter cable

Junction

Glass Capillary

pH Range

0 to 14

Type

pH/ATC Combination Electrode

For Use With (Equipment)

Mettler Toledo Five and Seven Series pH Meters

Isopotential Point

7

Precision

0.01

Length (Metric)

120 mm

Diameter (Metric)

12 mm

Connector Types

BNC/RCA

Material

Epoxy Body

Temperature (Metric) Operating

0°C to 80°C

Filling Solution Type

None required

Internal Reference

ROSS

pH Relative Accuracy

0.03 pH for buffers using automatic temperature compensation

Warranty

18 Months

Length (Metric) Cable

1 m

Related Products

Img

Fischer Scientific

13-642-675

--

Img

Fischer Scientific

13-641-981PMO

--

Img

Fischer Scientific

13-642-676

--

Img

Fischer Scientific

13-641-982PMO

--

Img

Fischer Scientific

13-642-677

--

Img

Fischer Scientific

13-641-981

--

Img

Fischer Scientific

13-641-982

--

Img

Thermo Scientific™

13-641-981PM

--

Description

  • Measure pH and Temperature with One Low-Maintenance Electrode Low ionic strength samples, such as clean waters, present a challenge to pH electrode performance
  • Sluggish response, poor accuracy and drift are common
  • The Thermo Scientific Orion ROSS Ultra 8107 Triode pH electrode responds within one minute, proving a stable, accurate reading
  • Complete your pH measurements faster
  • Get long, maintenance-free electrode lifetime with special long-life gel and innovative capillary glass junction design
  • Maintain sample integrity, even in TRIS buffers; ROSS double junction design electrodes contain no silver, which can bind with biological samples
  • With built-in temperature sensors, these electrodes offer a convenient solution for your routine sample measurements
  • Compatible with Thermo Scientific™ Orion™ Versa Star™, Thermo Scientific™ Orion Star™ A, and Thermo Scientific™ Orion™ Dual Star™ meters, as well as Mettler Toledo™ pH meters
  • Target Markets: Pharmaceutical/Biopharmaceutical Food Manufacturing Academic/Government Environmental Applications: Quality Control Research General Purpose

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-642-675PMO

--


Description:
Orion ROSS Ultra Low Maintenance pH/ATC Triode Combination Electrodes with a BNC and RCA Connector and 1 meter cable

Junction:
Glass Capillary

pH Range:
0 to 14

Type:
pH/ATC Combination Electrode

For Use With (Equipment):
Mettler Toledo Five and Seven Series pH Meters

Isopotential Point:
7

Precision:
0.01

Length (Metric):
120 mm

Diameter (Metric):
12 mm

Connector Types:
BNC/RCA

Material:
Epoxy Body

Temperature (Metric) Operating:
0°C to 80°C

Filling Solution Type:
None required

Internal Reference:
ROSS

pH Relative Accuracy:
0.03 pH for buffers using automatic temperature compensation

Warranty:
18 Months

Length (Metric) Cable:
1 m

Img

Fischer Scientific

13-642-676

--


Description:
Orion ROSS Ultra Refillable pH/ATC Triode Combination Electrodes with a BNC and RCA Connector and 1 meter cable

Junction:
Glass Fiber

pH Range:
0 to 14

Type:
pH/ATC Combination Electrode

For Use With (Equipment):
Mettler Toledo Five and Seven series pH meters

Isopotential Point:
7

Precision:
0.01

Length (Metric):
120 mm

Diameter (Metric):
12 mm

Connector Types:
BNC Waterproof, RCA

Material:
Epoxy Body

Temperature (Metric) Operating:
0°C to 100°C

Filling Solution Type:
ROSS electrode 3 M KCl fill solution (Cat. No. 810007)

Internal Reference:
ROSS

pH Relative Accuracy:
0.03 pH for buffers using automatic temperature compensation

Warranty:
2 Years

Length (Metric) Cable:
1 m

Img

Fischer Scientific

13-642-677

--


Description:
Orion ROSS Ultra Glass Triode pH/ATC Combination Electrodes with a BNC and RCA Connector and 1 meter cable

Junction:
Ceramic

pH Range:
0 to 14

Type:
pH/ATC Combination Electrode

For Use With (Equipment):
Mettler Toledo Five and Seven series pH meters

Isopotential Point:
7

Precision:
0.01

Length (Metric):
120 mm

Diameter (Metric):
12 mm

Connector Types:
BNC Waterproof, RCA

Material:
Chemical Resistant Glass Body

Temperature (Metric) Operating:
0°C to 100°C

Filling Solution Type:
ROSS electrode 3 M KCl fill solution (Cat. No. 810007)

Internal Reference:
ROSS

pH Relative Accuracy:
0.03 pH for buffers using automatic temperature compensation

Warranty:
2 Years

Length (Metric) Cable:
1 m

Img

Thermo Scientific™

13-642-686

--


Description:
654205

Junction:
__

pH Range:
__

Type:
__

For Use With (Equipment):
Surfactant Ion Selective Electrode

Isopotential Point:
__

Precision:
__

Length (Metric):
__

Diameter (Metric):
__

Connector Types:
__

Material:
__

Temperature (Metric) Operating:
__

Filling Solution Type:
__

Internal Reference:
__

pH Relative Accuracy:
__

Warranty:
__

Length (Metric) Cable:
__