material

polyester supportpolyethersulfone polypropylene (gamma-stable)polypropylene housingpolypropylene vent cappolysulfone silicone seal

Quality Level

400

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

non-sterile

Sterilization Compatibility

gamma compatible

product line

Opticap® XL 5

feature

gamma compatiblehydrophilic

manufacturer/tradename

Millipore Express®

parameter

≤17.4 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)1.0 bar max. inlet pressure (15 psi) at 80 °C100 psi max. differential pressure (6.9 bar) (intermittent)2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)2.75 bar max. inlet pressure (40 psi) at 60 °C25 °C max. inlet temp.5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)80 psi max. differential pressure (5.5 bar) (continuous)80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

Related Products

Img

Millipore

KGEPG05HH1

inlet connection diam. 9/16 in., Op...

Img

Millipore

KGEPG03TH3

inlet connection diam. 1.5 in., Opt...

Img

Millipore

KHGEG05HH1

Opticap® XL 5, inlet connection dia...

Img

Millipore

KHGEG05TH1

Opticap® XL 5, inlet connection dia...

Img

Millipore

KHGEG05TT1

inlet connection diam. 1.5 in., Opt...

Img

Millipore

KGEPG015FF3

Opticap® XL 150, inlet connection d...

Description

  • General description: Device Configuration: Capsule
  • Packaging: Double Easy-Open bag
  • Other Notes: These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
  • Preparation Note: Sterilization MethodGamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
  • Analysis Note: Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
  • Legal Information: ASTM is a registered trademark of American Society for Testing and Materials
  • Disclaimer: EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

Compare Similar Items

Show Difference

Img

Millipore

KGEPG05TH1

inlet connection diam. 1.5 in., Opt...


material:
polyester supportpolyethersulfone polypropylene (gamma-stable)polypropylene housingpolypropylene vent cappolysulfone silicone seal

Quality Level:
400

reg. compliance:
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility:
non-sterile

Sterilization Compatibility:
gamma compatible

product line:
Opticap® XL 5

feature:
gamma compatiblehydrophilic

manufacturer/tradename:
Millipore Express®

parameter:
≤17.4 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)1.0 bar max. inlet pressure (15 psi) at 80 °C100 psi max. differential pressure (6.9 bar) (intermittent)2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)2.75 bar max. inlet pressure (40 psi) at 60 °C25 °C max. inlet temp.5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 25 °C6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)80 psi max. differential pressure (5.5 bar) (continuous)80 psig max. inlet pressure

technique(s):
sterile filtration: suitable

Img

Millipore

KGEPS006FF3

sterile, Opticap® XL 600, inlet con...


material:
polyethersulfone polyethylene supportpolypropylene (gamma-stable)polypropylene housingpolypropylene vent cappolysulfone silicone seal

Quality Level:
400

reg. compliance:
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility:
irradiatedsterile

Sterilization Compatibility:
__

product line:
Opticap® XL 600

feature:
hydrophilic

manufacturer/tradename:
Millipore Express®

parameter:
≤5.8 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)1.0 bar max. inlet pressure (15 psi) at 80 °C100 psi max. differential pressure (6.9 bar) (intermittent)2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)2.75 bar max. inlet pressure (40 psi) at 60 °C25 °C max. inlet temp.5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 23 °C6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)80 psi max. differential pressure (5.5 bar) (continuous)80 psig max. inlet pressure

technique(s):
sterile filtration: suitable

Img

Millipore

KGEPS006FF3

sterile, Opticap® XL 600, inlet con...


material:
polyethersulfone polyethylene supportpolypropylene (gamma-stable)polypropylene housingpolypropylene vent cappolysulfone silicone seal

Quality Level:
400

reg. compliance:
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility:
irradiatedsterile

Sterilization Compatibility:
__

product line:
Opticap® XL 600

feature:
hydrophilic

manufacturer/tradename:
Millipore Express®

parameter:
≤5.8 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)1.0 bar max. inlet pressure (15 psi) at 80 °C100 psi max. differential pressure (6.9 bar) (intermittent)2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)2.75 bar max. inlet pressure (40 psi) at 60 °C25 °C max. inlet temp.5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 23 °C6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)80 psi max. differential pressure (5.5 bar) (continuous)80 psig max. inlet pressure

technique(s):
sterile filtration: suitable

Img

Millipore

KGEPS006FH3

sterile, Opticap® XL 600, inlet con...


material:
polyethersulfone polyethylene supportpolypropylene (gamma-stable)polypropylene housingpolypropylene vent cappolysulfone silicone seal

Quality Level:
400

reg. compliance:
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility:
irradiatedsterile

Sterilization Compatibility:
__

product line:
Opticap® XL 600

feature:
hydrophilic

manufacturer/tradename:
Millipore Express®

parameter:
≤5.8 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)1.0 bar max. inlet pressure (15 psi) at 80 °C100 psi max. differential pressure (6.9 bar) (intermittent)2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)2.75 bar max. inlet pressure (40 psi) at 60 °C25 °C max. inlet temp.5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)5.5 bar max. inlet pressure (80 psi) at 23 °C6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)80 psi max. differential pressure (5.5 bar) (continuous)80 psig max. inlet pressure

technique(s):
sterile filtration: suitable