IOPQPE03813

Unity Lab Services™ Thermo Scientific™ Laboratory Refrigerator Validation Service with Temperature Map

Manufacturer: Unity Lab Services™

Select a Size

Pack Size SKU Availability Price
Each of 1 IOPQPE03813-Each-of-1 In Stock ₹ 4,83,414.00

IOPQPE03813 - Each of 1

₹ 4,83,414.00

In Stock

Quantity

1

Base Price: ₹ 4,83,414.00

GST (18%): ₹ 87,014.52

Total Price: ₹ 5,70,428.52

For Use With (Equipment)

Thermo Scientific Laboratory Refrigerator including Thermo Scientific TSX505

Service Offering

Industry-Exclusive, No-Charge Requalification Guarantee. Unity Lab Services is the only OEM service provider to offer a guarantee and promise to requalify instruments and equipment at no charge if a key component fails while under the original factory warranty or a qualifying instrument service plan.

Includes

Travel to major metropolitan areas. Does not include Installation. Instrument must be installed, powered-up and set temperature point for 24 hours before on-site service

Description

Validation (IQ/OQ) includes a standardized protocol procedure, IQ: Verify Installation and environmental conditions, OQ: Verify operation to design specification, perform empty chamber temperature mapping, open door and power loss testing. Temperature Mapping: 24 hours of multi-point mapping.

Location

Contact your local sales representative for a list of standard and extended coverage areas.

Related Products

Img

Unity Lab Services™

IOQPE03813

--

Img

Unity Lab Services™

IOQPE33921

--

Img

Unity Lab Services™

IOQPE30810

--

Img

Unity Lab Services™

IOQPE03506

--

Img

Unity Lab Services™

IOPQDE03813

--

Img

Unity Lab Services™

11-675-342

--

Img

Unity Lab Services™

IOQDE03811

--

Img

Unity Lab Services™

11-675-361

--

Description

  • IQ Unpacking, Assembly and Installation Verifies that the equipment, manuals, supplies and any other accessories arrived undamaged as specified in the sales order
  • Verifies equipment is assembled and installed and any initial diagnostics tests have been performed
  • Any abnormal event(s) observed during assembly and installation have been documented
  • Utility, Facility and Environment Verifies that the installation site satisfactorily meets manufacturer-specified environmental requirements
  • OQ System Component Information Detailed configuration information for each system component have been recorded
  • OQ Limits: Record a list of manufacturer recommended limits for ensuring that the system is operating as expected
  • Equipment Operational Tests and Results: Test important equipment functions to verify that the equipment operates as intended by the manufacturer and required by the user
  • This is a group of selected important equipment parameters for testing according to the intended use of the equipment
  • - Key Tests: Door Ajar, Power Failure, Temperature Alerts Temp Map Temperature Mapping Tests and Results: Test important equipment capabilities for ensuring that the equipment is performing in accordance with the intended use of the system
  • Multi-Point Temperature Mapping for a 24 hour period with 1 minute data intervals.

Compare Similar Items

Show Difference

Img

Unity Lab Services™

IOPQPE03813

--


For Use With (Equipment):
Thermo Scientific Laboratory Refrigerator including Thermo Scientific TSX505

Service Offering:
Industry-Exclusive, No-Charge Requalification Guarantee. Unity Lab Services is the only OEM service provider to offer a guarantee and promise to requalify instruments and equipment at no charge if a key component fails while under the original factory warranty or a qualifying instrument service plan.

Includes:
Travel to major metropolitan areas. Does not include Installation. Instrument must be installed, powered-up and set temperature point for 24 hours before on-site service

Description:
Validation (IQ/OQ) includes a standardized protocol procedure, IQ: Verify Installation and environmental conditions, OQ: Verify operation to design specification, perform empty chamber temperature mapping, open door and power loss testing. Temperature Mapping: 24 hours of multi-point mapping.

Location:
Contact your local sales representative for a list of standard and extended coverage areas.

Img

Unity Lab Services™

IOQDE03484

--


For Use With (Equipment):
Thermo Scientific Ultra-Low Temperature Freezers including all Thermo Scientific Ultra-Low Temperature Freezers Models: Thermo Scientific TDE, Forma FDE, Revco RDE, Isotemp IUE

Service Offering:
__

Includes:
IQ/OQ Documentation

Description:
Documentation Only for the following, Services Not Included: Validation (IQ/OQ) includes a standardized protocol procedure, IQ: Verify Installation and environmental conditions, OQ: Verify operation to design specification, perform empty chamber temperature mapping, open door and power loss testing.

Location:
Contact your local sales representative for a list of standard and extended coverage areas.

Img

Unity Lab Services™

IOQDE03486

--


For Use With (Equipment):
Thermo Scientific Biological Safety Cabinets and Clean Benches including Thermo Scientific HeraGuard Eco

Service Offering:
__

Includes:
IQ/OQ Documentation

Description:
Documentation Only for the following, Services Not Included: Validation (IQ/OQ) includes a standardized protocol procedure, IQ: Verify Installation and environmental conditions, OQ: Verify operation to design specification, Filter leakage, Air Velocity, Electrical Safety, Air-Flow Smoke Pattern, KI-DISCUS testing.

Location:
Contact your local sales representative for a list of standard and extended coverage areas.

Img

Unity Lab Services™

IOQDE03493

--


For Use With (Equipment):
Thermo Scientific Centrifugation including Superspeed and Ultra centrifuges: Thermo Scientific, Sorvall

Service Offering:
__

Includes:
IQ/OQ Documentation

Description:
__

Location:
Contact your local sales representative for a list of standard and extended coverage areas.