50-199-7799

Hach Lange™ TL2310 LED Turbidimeter, ISO, 0 - 1000 NTU

Manufacturer: Hach Lange™

Select a Size

Pack Size SKU Availability Price
Each of 1 50-199-7799-Each-of-1 In Stock ₹ 3,52,401.11

50-199-7799 - Each of 1

₹ 3,52,401.11

In Stock

Quantity

1

Base Price: ₹ 3,52,401.11

GST (18%): ₹ 63,432.20

Total Price: ₹ 4,15,833.31

Type

Turbidity Meter

Display Type

Color Touch Screen

Automatic Range Selection

Yes

Warranty

1 Year

Light Source

LED

Response Time

6.8 Sec. (Signal Averaging Off), 14 Sec. (Signal Averaging On)

ISO Accepted Methods

ISO 7027

Related Products

Img

Hach Lange™

50-199-7800

--

Img

Fischer Scientific

13-000-102

--

Img

Fischer Scientific

9072015

Provides accurate results with simp...

Img

Fischer Scientific

13-000-101

--

Img

Fischer Scientific

03-920-551

--

Img

LaMotte™

S72349

--

Img

Thermo Scientific™

13-650-100

--

Img

Thermo Scientific™

13-650-100PM

--

Description

  • Trusted measurement for high turbidity applications; simplified
  • The new TL23 Series laboratory turbidimeters blend trusted technology and improved features to simplify testing in the most demanding wastewater and industrial applications
  • Improved and intuitive design A smart device for more reliable measurements Easy to use
  • Easy to Be Right Improved and intuitive design The TL23 Series’ large full colour touch screen display and intuitive user interface accelerate setup, calibration and measurement
  • An easy interface and guided procedures give you confidence in your results
  • A smart device for more reliable measurements The TL23 Series ensures stable readings and accurate analysis by capturing turbidity readings once the device detects sample stability
  • This quality step removes subjectivity and the need for repeated measurements
  • Easy to use
  • Easy to Be Right The TL23 Series provides everything you need at your fingertips
  • With a USB port for easy data export, sample identification for traceability, and self-diagnostics for quality assurance, Hach™makes it easy to Be Right
  • What's included? TL2310 Turbidimeter, silicone oil, oiling cloth, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover Specifications Accuracy: ±2% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU Air purge: Dry nitrogen or instrument grade air (ANSI MC 11.1, 1975) 0.05 L/s at 69 kPa (10 psig); 138 kPa (20 psig) max Hose barb connection for 1/8-inch tubing Certifications: CE, KC, RCM Communication: USB Compliance: ISO Data logging: 2000 total logs, includes reading log, verification log and calibration log Dimensions (H x W x D): 153 mm x 395 mm x 305 mm Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (LED) at 860 ± 30 nm Measurement method: Nephelometric Model: TL2310 ISO Operating temperature range: 0 - 40 °C Power requirements (Amps): 3.4 A Power requirements (Hz): 50/60 Hz Power requirements (Voltage): 100 - 240 VAC Range: 0 - 1000 NTU NTU/FNU: 0 - 1000 Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging on or off Region: Global Regulatory: Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033 Repeatability: ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions) Response time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used
  • Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) Stabilisation time: Immediately Storage conditions: -20 to 60 °C Units: FNU and NTU Weight: 3.0 kg What's included?: TL2310 Turbidimeter, silicone oil, oiling cloth, 1-inch sample cells (30 mL) with caps (6x), Gelex secondary turbidity standardization kit, Stablcal calibration kit, power supply, power cord, dust cover

Compare Similar Items

Show Difference

Img

Hach Lange™

50-199-7799

--


Type:
Turbidity Meter

Display Type:
Color Touch Screen

Automatic Range Selection:
Yes

Warranty:
1 Year

Light Source:
LED

Response Time:
6.8 Sec. (Signal Averaging Off), 14 Sec. (Signal Averaging On)

ISO Accepted Methods:
ISO 7027

Img

Hach Lange™

50-199-7800

--


Type:
Turbidity Meter

Display Type:
Color Touch Screen

Automatic Range Selection:
Yes

Warranty:
1 Year

Light Source:
Tungsten

Response Time:
6.8 Sec. (Signal Averaging Off), 14 Sec. (Signal Averaging On)

ISO Accepted Methods:
__

Img

Hach Company

50-199-7801

--


Type:
__

Display Type:
__

Automatic Range Selection:
__

Warranty:
__

Light Source:
__

Response Time:
__

ISO Accepted Methods:
__

Img

Hach Company

50-199-7802

--


Type:
__

Display Type:
__

Automatic Range Selection:
__

Warranty:
__

Light Source:
__

Response Time:
__

ISO Accepted Methods:
__