12392-U

Metal Packed GC Column (fits Agilent, Configuration "A")

phase none, matrix 60/80 Carboxen-1000 support, L × O.D. × I.D. 15.0 ft (4.6 m) × 1/8 in. × 2.1 mm

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
1 EA 12392-U-1-EA In Stock ₹ 46,179.45

12392-U - 1 EA

₹ 46,179.45

In Stock

Quantity

1

Base Price: ₹ 46,179.45

GST (18%): ₹ 8,312.301

Total Price: ₹ 54,491.751

material

stainless steel column

Quality Level

100

manufacturer/tradename

Agilent

parameter

0-225 °C temperature (isothermal or programmed)

technique(s)

gas chromatography (GC): suitable

L × O.D. × I.D.

15.0 ft (4.6 m) × 1/8 in. × 2.1 mm

matrix

60/80 Carboxen-1000 support

matrix active group

none phase

column type

packed GC

compatibility

for use with Agilent Configuration A

Related Products

Img

Supelco

12390-U

phase none, matrix 60/80 Carboxen-1...

Img

Supelco

12380

phase none, matrix 40/60 Carboxen-1...

Img

Supelco

13038-U

phase none, matrix 80/100 HayeSep Q...

Img

Supelco

12370-U

phase none, matrix 40/60 Carboxen-1...

Img

Supelco

13067-U

phase none, matrix 80/100 HayeSep N...

Img

Supelco

12594

phase 3% SP®-1500, matrix 80/120 Ca...

Img

Supelco

13128-U

phase 5% Carbowax 20M, matrix 80/10...

Img

Supelco

13036-U

phase none, matrix 45/60 Molecular ...

Description

  • General description: Packed column made up of stainless steel are basically employed when higher carrier gas flow rates are employed as they can sustain elevated pressure. Stainless steel columns are usually washed with dilute hydrochloric acid, then with water followed by methanol, acetone, methylene dichloride and n-hexane in order to remove any corrosion products and traces of lubricating agents.[1]
  • Application: Carboxen 1000 packed in a stainless steel column maybe used in the anaerobic chamber for conductance of research with methanogenic archaea.[2]

SAFETY INFORMATION

WGK

nwg

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Compare Similar Items

Show Difference

Img

Supelco

12392-U

phase none, matrix 60/80 Carboxen-1...


material:
stainless steel column

Quality Level:
100

manufacturer/tradename:
Agilent

parameter:
0-225 °C temperature (isothermal or programmed)

technique(s):
gas chromatography (GC): suitable

L × O.D. × I.D.:
15.0 ft (4.6 m) × 1/8 in. × 2.1 mm

matrix:
60/80 Carboxen-1000 support

matrix active group:
none phase

column type:
packed GC

compatibility:
for use with Agilent Configuration A

Img

Sigma Aldrich

123943

99%...


material:
__

Quality Level:
200

manufacturer/tradename:
__

parameter:
__

technique(s):
__

L × O.D. × I.D.:
__

matrix:
__

matrix active group:
__

column type:
__

compatibility:
__

Img

Sigma Aldrich

1239504

United States Pharmacopeia (USP) Re...


material:
__

Quality Level:
__

manufacturer/tradename:
USP

parameter:
__

technique(s):
__

L × O.D. × I.D.:
__

matrix:
__

matrix active group:
__

column type:
__

compatibility:
__

Img

Sigma Aldrich

123986

97%...


material:
__

Quality Level:
__

manufacturer/tradename:
__

parameter:
__

technique(s):
__

L × O.D. × I.D.:
__

matrix:
__

matrix active group:
__

column type:
__

compatibility:
__