1.00798

Phosphate Test

photometric, 1.0-100.0 mg/L (PO4-P), 3-307 mg/L (PO43-), 2-229 mg/L (P2O5), Spectroquant®

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
100 TESTS 1.00798-100-TESTS In Stock ₹ 17,850.00

1.00798 - 100 TESTS

₹ 17,850.00

In Stock

Quantity

1

Base Price: ₹ 17,850.00

GST (18%): ₹ 3,213.00

Total Price: ₹ 21,063.00

product line

Spectroquant®

Quality Level

100

usage

sufficient for 100 tests

specific analyte(s)

phosphate

measuring range

1.0-100.0 mg/L (PO4-P)2-229 mg/L (P2O5)3-307 mg/L (PO43-)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method

photometric (Phosphomolybdenum blue)

storage temp.

15-25°C

Related Products

Img

Supelco

1.00616

photometric, 3.0-100.0 mg/L (PO4-P)...

Img

Supelco

1.00673

photometric, 3.0-100.0 mg/L (PO4-P)...

Img

Supelco

1.14566

photometric, 0.20-5.00 mg/L (Zn), S...

Img

Supelco

1.14553

photometric, 0.05-8.00 mg/L (Cu), S...

Img

Supelco

1.14554

photometric, 0.10-6.00 mg/L (Ni), S...

Img

Supelco

1.14562

photometric, 5.0-50.0 mg/L (K), Spe...

Img

Supelco

1.01758

photometric, 0.40-8.00 mmol/L (CaCO...

Img

Supelco

1.14729

photometric, 0.5-25.0 mg/L (PO4-P),...

Description

  • General description: (o-phosphate) Method: photometric, PMB 1.0 - 100.0 mg/l PO₄-P 3 - 307 mg/l PO₄³⁻ 2 - 229 mg/l P₂O₅ Spectroquant® The method is analogous to EPA 365.2+3, APHA 4500-P E, and DIN EN ISO 6878. The Spectroquant® Phosphate Reagent Test allows the accurate quantification of phosphate. Elevated levels of phosphate might lead to eutrophication of water bodies, which is a risk to the environment. Therefore, the concentration of phosphate in drinking water and wastewater is regulated in many countries. Further applications are the determination of phosphate in foods & beverages (e.g. beer) and in environmental and agricultural samples (e.g. soil).The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet. All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
  • Application: Effects of Two Remineralizing Agents in Combination with Er:YAG and CO(2) Laser Irradiation on Microhardness of Demineralized Enamel: This study highlights the use of phosphate tests in dental research, specifically in measuring the efficacy of remineralizing agents combined with laser treatment to enhance enamel hardness, which is crucial for dental health and preventive care (Mapar M et al., 2024). Zinc and Silicon Nano-Fertilizers Influence Ionomic and Metabolite Profiles in Maize to Overcome Salt Stress: This research utilizes phosphate tests in the study of plant physiology, specifically to gauge the efficacy of nano-fertilizers in enhancing phosphate uptake under salt stress conditions, providing insights into sustainable agricultural practices (Shoukat A et al., 2024). Investigation of Mechanical Properties of Polymer-Infiltrated Tetrapodal Zinc Oxide in Different Variants: Applies phosphate testing in the field of materials science to assess the interaction of phosphate with novel composite materials, thereby informing the development of more durable and efficient materials for various industrial applications (Scherer F et al., 2024).
  • Legal Information: SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

SAFETY INFORMATION

Pictograms

GHS05

Signal Word

Danger

Hazard Statements

H290 - H314

Precautionary Statements

P234 - P280 - P303 + P361 + P353 - P304 + P340 + P310 - P305 + P351 + P338 - P363

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Storage Class Code

8B - Non-combustible, corrosive hazardous materials

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Compare Similar Items

Show Difference

Img

Supelco

1.00798

photometric, 1.0-100.0 mg/L (PO4-P)...


product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 100 tests

specific analyte(s):
phosphate

measuring range:
1.0-100.0 mg/L (PO4-P)2-229 mg/L (P2O5)3-307 mg/L (PO43-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Phosphomolybdenum blue)

storage temp.:
15-25°C

Img

Supelco

1.00801

pkg of 20 labels blank adhesive lab...


product line:
__

Quality Level:
__

usage:
__

specific analyte(s):
__

measuring range:
__

technique(s):
__

compatibility:
__

detection method:
__

storage temp.:
room temp

Img

Supelco

1.00801

pkg of 20 labels blank adhesive lab...


product line:
__

Quality Level:
__

usage:
__

specific analyte(s):
__

measuring range:
__

technique(s):
__

compatibility:
__

detection method:
__

storage temp.:
room temp

Img

SAFC

1.00802

crystalline, EMPROVE® ESSENTIAL, Ph...


product line:
EMPROVE® ESSENTIAL

Quality Level:
500

usage:
__

specific analyte(s):
__

measuring range:
__

technique(s):
__

compatibility:
__

detection method:
__

storage temp.:
__