1.14546

Phosphate Test, photometric

photometric, 0.5-25.0 mg/L (PO4-P), 1.5-76.7 mg/L (PO43-), 1.1-57.3 mg/L (P2O5), Spectroquant®

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
25 TESTS 1.14546-25-TESTS In Stock ₹ 19,090.00

1.14546 - 25 TESTS

₹ 19,090.00

In Stock

Quantity

1

Base Price: ₹ 19,090.00

GST (18%): ₹ 3,436.20

Total Price: ₹ 22,526.20

product name

Phosphate Cell Test, photometric, 0.5-25.0 mg/L (PO4-P), 1.5-76.7 mg/L (PO43-), 1.1-57.3 mg/L (P2O5), Spectroquant®

product line

Spectroquant®

Quality Level

100

usage

sufficient for 25 tests

specific analyte(s)

phosphate

measuring range

0.5-25.0 mg/L (PO4-P)1.1-57.3 mg/L (P2O5)1.5-76.7 mg/L (PO43-)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method

photometric (Vanadato-molybdate)

storage temp.

15-25°C

Description

  • General description: (o-phosphate) Method: Photometric, 0.5 - 25.0 mg/L (PO4-P), 1.5 - 76.7 mg/L (PO43-), 1.1 - 57.3 mg/L (P2O5), Spectroquant®The method is analogous to APHA 4500-P C. This Spectroquant® Cell Test is especially designed for the analysis of processes water. In order to avoid long downtimes and intensive maintenance costs of processes water systems a precisely adjusted level of phosphate in the water is paramount to ensure water pipes are protected and corrosion is limited to a minimum. The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided. All Spectroquant® Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
  • Legal Information: SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

SAFETY INFORMATION

Pictograms

GHS05

Signal Word

Danger

Hazard Statements

H290 - H314

Precautionary Statements

P234 - P280 - P303 + P361 + P353 - P304 + P340 + P310 - P305 + P351 + P338 - P363

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

Storage Class Code

8B - Non-combustible, corrosive hazardous materials

WGK

WGK 2

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Compare Similar Items

Show Difference

Img

Supelco

1.14546

photometric, 0.5-25.0 mg/L (PO4-P),...


product name:
Phosphate Cell Test, photometric, 0.5-25.0 mg/L (PO4-P), 1.5-76.7 mg/L (PO43-), 1.1-57.3 mg/L (P2O5), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 25 tests

specific analyte(s):
phosphate

measuring range:
0.5-25.0 mg/L (PO4-P)1.1-57.3 mg/L (P2O5)1.5-76.7 mg/L (PO43-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Vanadato-molybdate)

storage temp.:
15-25°C

Img

Supelco

1.14547

photometric, 0.03-2.30 mg/L (NO2-),...


product name:
Nitrite Cell Test, photometric, 0.03-2.30 mg/L (NO2-), 0.010-0.700 mg/L (NO2-N), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 25 tests

specific analyte(s):
nitrite

measuring range:
0.010-0.700 mg/L (NO2-N)0.03-2.30 mg/L (NO2-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Griess’ reaction)

storage temp.:
__

Img

Supelco

1.14548

photometric, 5-250 mg/L (SO42-), Sp...


product name:
Sulfate Cell Test, photometric, 5-250 mg/L (SO42-), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 25 tests

specific analyte(s):
sulfate

measuring range:
5-250 mg/L (SO42-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Barium sulfate, turbidimetric)

storage temp.:
15-25°C

Img

Supelco

1.14549

photometric, 0.05-4.00 mg/L (Fe), S...


product name:
Iron Cell Test, photometric, 0.05-4.00 mg/L (Fe), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 25 tests

specific analyte(s):
iron

measuring range:
0.05-4.00 mg/L (Fe)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Triazine)

storage temp.:
15-25°C