1.14770

Manganese Test, photometric

photometric, 0.010-10.00 mg/L (Mn), Spectroquant®

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
250 TESTS 1.14770-250-TESTS In Stock ₹ 20,070.00
500 TESTS 1.14770-500-TESTS In Stock ₹ 36,789.99

1.14770 - 250 TESTS

₹ 20,070.00

In Stock

Quantity

1

Base Price: ₹ 20,070.00

GST (18%): ₹ 3,612.60

Total Price: ₹ 23,682.60

product name

Manganese Test, photometric, 0.010-10.00 mg/L (Mn), Spectroquant®

product line

Spectroquant®

Quality Level

100

usage

sufficient for 250 tests (depending on package size) sufficient for 500 tests

specific analyte(s)

manganese

measuring range

0.010-10.00 mg/L (Mn)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method

photometric (Formaldioxime)

storage temp.

15-25°C

Related Products

Img

Supelco

1.00816

photometric, 0.10-5.00 mg/L (Mn), S...

Img

Supelco

1.14598

photometric, 0.10-20.0 mg/L (F), Sp...

Img

Supelco

1.14761

photometric, 0.0025-5.00 mg/L (Fe),...

Img

Supelco

1.01846

photometric, 0.005-2.00 mg/L (Mn), ...

Img

Supelco

1.00607

photometric, 0.010-4.00 mg/L (O3), ...

Img

Supelco

1.14752

photometric, 0.010-3.00 mg/L (NH4-N...

Img

Supelco

1.00598

photometric, 0.010-6.00 mg/L (Cl2),...

Img

Supelco

1.00602

photometric, 0.010-6.00 mg/L (Cl2),...

Description

  • General description: Method: photometric 0.010 - 10.00 mg/l Mn Spectroquant® The method is analogous to DIN 38406-2.This Spectroquant® Manganese Reagent Test allows the accurate quantification of the manganese(II) ions content in aqueous samples. Method applied: In alkaline solution manganese(II) ions react with an oxime to form a red-brown complex which is determined photometrically. The Spectroquant®Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet. All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
  • Legal Information: SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

SAFETY INFORMATION

Pictograms

GHS05,GHS07,GHS08,GHS09

Signal Word

Danger

Hazard Statements

H290 - H314 - H317 - H335 - H341 - H350 - H373 - H410

Precautionary Statements

P202 - P273 - P280 - P303 + P361 + P353 - P304 + P340 + P310 - P305 + P351 + P338

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 3 - Carc. 1B - Eye Dam. 1 - Met. Corr. 1 - Muta. 2 - Skin Corr. 1B - Skin Sens. 1 - STOT RE 2 Oral - STOT SE 3

Target Organs

Respiratory system, spleen

Storage Class Code

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Compare Similar Items

Show Difference

Img

Supelco

1.14770

photometric, 0.010-10.00 mg/L (Mn),...


product name:
Manganese Test, photometric, 0.010-10.00 mg/L (Mn), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 250 tests (depending on package size) sufficient for 500 tests

specific analyte(s):
manganese

measuring range:
0.010-10.00 mg/L (Mn)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Formaldioxime)

storage temp.:
15-25°C

Img

Supelco

1.14773

photometric, 0.2-20.0 mg/L (NO3-N),...


product name:
Nitrate Test, photometric, 0.2-20.0 mg/L (NO3-N), 0.89-88.5 mg/L (NO3-), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 100 tests

specific analyte(s):
nitrate

measuring range:
0.2-20.0 mg/L (NO3-N)0.89-88.5 mg/L (NO3-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Nitrospectral)

storage temp.:
15-25°C

Img

Supelco

1.14774

0.1-10 mg/L (NO₂⁻), MQuant®...


product name:
Nitrite Test, colorimetric, 0.1-10 mg/L (NO2-), for use with MCOLORTEST®

product line:
__

Quality Level:
100

usage:
__

specific analyte(s):
nitrite

measuring range:
0.1-10 mg/L (NO2-)

technique(s):
__

compatibility:
for use with MCOLORTEST®

detection method:
colorimetric

storage temp.:
15-25°C

Img

Supelco

1.14774

0.1-10 mg/L (NO₂⁻), MQuant®...


product name:
Nitrite Test, colorimetric, 0.1-10 mg/L (NO2-), for use with MCOLORTEST®

product line:
__

Quality Level:
100

usage:
__

specific analyte(s):
nitrite

measuring range:
0.1-10 mg/L (NO2-)

technique(s):
__

compatibility:
for use with MCOLORTEST®

detection method:
colorimetric

storage temp.:
15-25°C