1.14776

Nitrite Test, photometric

photometric, 0.002-1.00 mg/L (NO2-N), 0.007-3.28 mg/L (NO2-), Spectroquant®

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
335 TESTS 1.14776-335-TESTS In Stock ₹ 18,950.00
1000 TESTS 1.14776-1000-TESTS In Stock ₹ 32,800.01

1.14776 - 335 TESTS

₹ 18,950.00

In Stock

Quantity

1

Base Price: ₹ 18,950.00

GST (18%): ₹ 3,411.00

Total Price: ₹ 22,361.00

product name

Nitrite Test, photometric, 0.002-1.00 mg/L (NO2-N), 0.007-3.28 mg/L (NO2-), Spectroquant®

product line

Spectroquant®

Quality Level

100

usage

sufficient for 1000 tests sufficient for 335 tests (depending on package size)

specific analyte(s)

nitrite

reaction suitability

reaction type: Griess reaction

measuring range

0.002-1.00 mg/L (NO2-N)0.007-3.28 mg/L (NO2-)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method

photometric (Griess’ reaction)

Description

  • General description: Method: photometric 0.002 - 1.00 mg/l NO₂-N 0.007 - 3.28 mg/l NO₂⁻ Spectroquant® The method is analogous to EPA 354.1, APHA 4500-NO2- B, and DIN EN 26 777. This Spectroquant® Nitrate Cell Test allows the accurate quantification of nitrate in water samples. Nitrate is an essential nutrient required for the growth of animals and plants. However, elevated levels of nitrate can be a health risk, in particular for pregnant women and infants. Therefore, nitrate levels in water sources are regulated in many countries. Method applied: In acidic solution nitrite ions react with sulfanilic acid to form a diazonium salt that reacts with N-(1-naphthyl)ethylenediamine dihydrochloride to form a red-violet azo dye which is determined photometrically. The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet. All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
  • Application: Clinical and laboratory features of urinary tract infections in young infants: Discusses diagnostic challenges and characteristics of urinary tract infections in infants, stressing the importance of accurate detection to guide treatment (Lo et al., 2018). Differentiating Kawasaki disease from urinary tract infection in febrile children with pyuria and C-reactive protein elevation: Focuses on differential diagnosis in pediatric care, which can influence the choice of nitrite tests for accurate and timely diagnosis (Han and Lee, 2018). Early features of Kawasaki disease with pyuria in febrile infants younger than 6 months: Addresses the overlap of urinary symptoms in Kawasaki disease, underscoring the utility of nitrite tests in complex cases (Yoon et al., 2018). Current practice on the management of pre-operative urine dipstick results in women undergoing gynaecological surgery in Wales: Reviews procedures related to pre-surgical care in gynaecology, indicating broader applications of nitrite testing in hospital protocols (Walker et al., 2019).
  • Legal Information: SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

SAFETY INFORMATION

Pictograms

GHS07

Signal Word

Warning

Hazard Statements

H315 - H317 - H319

Precautionary Statements

P261 - P264 - P272 - P280 - P302 + P352 - P305 + P351 + P338

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1

Storage Class Code

11 - Combustible Solids

WGK

WGK 2

Compare Similar Items

Show Difference

Img

Supelco

1.14776

photometric, 0.002-1.00 mg/L (NO2-N...


product name:
Nitrite Test, photometric, 0.002-1.00 mg/L (NO2-N), 0.007-3.28 mg/L (NO2-), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 1000 tests sufficient for 335 tests (depending on package size)

specific analyte(s):
nitrite

reaction suitability:
reaction type: Griess reaction

measuring range:
0.002-1.00 mg/L (NO2-N)0.007-3.28 mg/L (NO2-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Griess’ reaction)

Img

Supelco

1.14777

0.1-5 mg/L (S²⁻), MQuant®...


product name:
Sulfide Test, colorimetric, 0.1-5 mg/L (S2-), for use with MCOLORTEST®

product line:
__

Quality Level:
100

usage:
__

specific analyte(s):
sulfide

reaction suitability:
__

measuring range:
0.1-5 mg/L (S2-)

technique(s):
__

compatibility:
for use with MCOLORTEST®

detection method:
colorimetric

Img

Supelco

1.14779

photometric, 0.020-1.50 mg/L (S2-),...


product name:
Sulfide Test, photometric, 0.020-1.50 mg/L (S2-), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 220 tests220 tests

specific analyte(s):
sulfide

reaction suitability:
__

measuring range:
0.020-1.50 mg/L (S2-)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Dimethyl-p-phenylenediamine)

Img

Supelco

1.14780

0.1-5 mg/L (Zn), MQuant®...


product name:
Zinc Test, colorimetric, 0.1-5 mg/L (Zn), for use with MQUANT®

product line:
__

Quality Level:
100

usage:
__

specific analyte(s):
zinc

reaction suitability:
__

measuring range:
0.1-5 mg/L (Zn)

technique(s):
__

compatibility:
for use with MQUANT®

detection method:
colorimetric