1.19251

Oxygen Scavengers Test, photometric

photometric, 0.09-2.17 mg/L (MEKO), 0.08-1.95 mg/L (ISA), 0.05-1.32 mg/L (Hydro), 0.027-0.667 mg/L (Carbohy), 0.020-0.500 mg/L (DEHA), Spectroquant®

Manufacturer: Supelco

Select a Size

Pack Size SKU Availability Price
200 TESTS 1.19251-200-TESTS In Stock ₹ 16,250.00

1.19251 - 200 TESTS

₹ 16,250.00

In Stock

Quantity

1

Base Price: ₹ 16,250.00

GST (18%): ₹ 2,925.00

Total Price: ₹ 19,175.00

product name

Oxygen Scavengers Test, photometric, 0.09-2.17 mg/L (MEKO), 0.08-1.95 mg/L (ISA), 0.05-1.32 mg/L (Hydro), 0.027-0.667 mg/L (Carbohy), 0.020-0.500 mg/L (DEHA), Spectroquant®

product line

Spectroquant®

Quality Level

100

usage

sufficient for 200 tests

analyte functional class(es)

oxygen scavengers

measuring range

0.020-0.500 mg/L (DEHA)0.027-0.667 mg/L (Carbohy)0.05-1.32 mg/L (Hydro)0.08-1.95 mg/L (ISA)0.09-2.17 mg/L (MEKO)

technique(s)

photometry: suitable

compatibility

for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method

photometric (Iron reduction)

storage temp.

15-25°C

Description

  • General description: Method: photometric 0.020 - 0.500 mg/l DEHA 0.027 - 0.667 mg/l Carbohy 0.053 - 1.315 mg/l Hydro 0.078 - 1.950 mg/l ISA 0.087 - 2.170 mg/l MEKO Spectroquant®This Spectroquant® Oxygen Scavengers Reagent Test allows the accurate quantification of the oxygen scavengers content in aqueous samples. Method applied: In the presence of oxygen scavengers iron(III) ions are reduced to iron(II) ions. These react with a triazine derivative (FerroZine™) to form a violet complex which is determined photometrically. The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet. All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
  • Application: Food Packaging and Shelf Life Extension: Oxygen scavengers are extensively used in food packaging to extend the shelf life of products by preventing oxidation. Recent research has demonstrated the application of oxygen scavengers in gel electromembrane extraction for the simultaneous determination of nitrate and nitrite in sausage samples. This green methodology enhances the accuracy of food quality assessments and ensures the safety of packaged foods (Samkumpim et al., Food Chemistry, 2023). Advanced Material Science: Oxygen scavengers are used in the development and characterization of advanced materials, including biodegradable films for active packaging. Recent research has explored the fabrication of ultraviolet light-driven green oxygen scavenging composites made of PVA/NRL for food packaging, providing an alternative to traditional metallic oxygen scavengers. This application demonstrates the potential for creating sustainable and efficient oxygen-scavenging materials (Ramakanth et al., Green Chemistry, 2024).
  • Analysis Note: Performance test: conforms
  • Legal Information: FerroZine is a trademark of Hach Company

SAFETY INFORMATION

Pictograms

GHS05,GHS07

Signal Word

Danger

Hazard Statements

H290 - H314 - H332

Precautionary Statements

P234 - P261 - P280 - P303 + P361 + P353 - P304 + P340 + P310 - P305 + P351 + P338

Hazard Classifications

Acute Tox. 4 Inhalation - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1

Supplementary Hazards

EUH071

Storage Class Code

8B - Non-combustible, corrosive hazardous materials

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Compare Similar Items

Show Difference

Img

Supelco

1.19251

photometric, 0.09-2.17 mg/L (MEKO),...


product name:
Oxygen Scavengers Test, photometric, 0.09-2.17 mg/L (MEKO), 0.08-1.95 mg/L (ISA), 0.05-1.32 mg/L (Hydro), 0.027-0.667 mg/L (Carbohy), 0.020-0.500 mg/L (DEHA), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 200 tests

analyte functional class(es):
oxygen scavengers

measuring range:
0.020-0.500 mg/L (DEHA)0.027-0.667 mg/L (Carbohy)0.05-1.32 mg/L (Hydro)0.08-1.95 mg/L (ISA)0.09-2.17 mg/L (MEKO)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Iron reduction)

storage temp.:
15-25°C

Img

Supelco

1.19253

photometric, 2-160 mg/L (cyanuric a...


product name:
Cyanuric Acid Test, photometric, 2-160 mg/L (cyanuric acid), Spectroquant®

product line:
Spectroquant®

Quality Level:
100

usage:
sufficient for 100 tests

analyte functional class(es):
__

measuring range:
2-160 mg/L (cyanuric acid)

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move 100for use with Spectroquant® Move DCfor use with Spectroquant® Nova 60 Afor use with Spectroquant® Prove 100for use with Spectroquant® Prove 300for use with Spectroquant® Prove 600

detection method:
photometric (Turbidity)

storage temp.:
15-25°C

Img

Supelco

1.19254

photometric, 0 - 2.00 mg/l Cl₂ (fre...


product name:
__

product line:
__

Quality Level:
100

usage:
sufficient for 100 tests

analyte functional class(es):
__

measuring range:
0-2.0 mg/L (Cl2)

technique(s):
photometry: suitable

compatibility:
for use with photometers from other manufacturers

detection method:
photometric (DPD)

storage temp.:
15-25°C

Img

Supelco

1.19301

traceable to NIST SRM 2032, 935a (f...


product name:
__

product line:
Spectroquant®

Quality Level:
200

usage:
__

analyte functional class(es):
__

measuring range:
__

technique(s):
photometry: suitable

compatibility:
for use with Spectroquant® Move DC

detection method:
__

storage temp.:
15-25°C