30274-U

Tedlar® SCV Gas Sampling Bag

5L w/ Thermogreen® LB-2 Septa

Manufacturer: Supelco

Synonym(S): Tedlar® Gas Sampling Bag

Select a Size

Pack Size SKU Availability Price
10 EA 30274-U-10-EA In Stock ₹ 24,534.90

30274-U - 10 EA

₹ 24,534.90

In Stock

Quantity

1

Base Price: ₹ 24,534.90

GST (18%): ₹ 4,416.282

Total Price: ₹ 28,951.182

product name

5L Tedlar® SCV Gas Sampling Bag w/Thermogreen® LB-2 Septa,

material

Tedlar® PVDF film

Quality Level

100

Agency

suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC)suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC)suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs))suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)suitable for NIOSH 3704 (Perchloroethylene)

description

Screw Cap Valve (SCV)septum type: yes; Thermogreen® LB-2

packaging

pkg of 10 bags

technique(s)

whole air sampling: suitable

W × L

12 in. × 14 in.

maximum volume

5 L

application(s)

air monitoringenvironmentalindustrial hygiene

Related Products

Img

Supelco

30276-U

10L w/ Thermogreen® LB-2 Septa...

Img

Supelco

30273-U

2L w/ Thermogreen® LB-2 Septa...

Img

Supelco

30285-U

3L w/ Thermogreen® LB-2 Septa...

Img

Supelco

30272-U

1L w/ Thermogreen® LB-2 Septa...

Img

Supelco

30284-U

0.6L w/Thermogreen® LB-2 Septa...

Img

Supelco

30291-U

3L w/ Thermogreen® LB-2 Septa...

Img

Supelco

30289-U

0.6L w/Thermogreen® LB-2 Septa...

Img

Supelco

24634

maximum volume 10 L, Push/Pull Lock...

Description

  • General description: Tedlar is recommended in several US EPA methods for sampling VOCs and sulfur compounds. Our Tedlar is made from a high-quality 2 mil Tedlar film for superior inertness, impermeability, sample integrity and good recovery data. Our Push Lock Valve (PLV) and seam-sealing process ensure that these bags are sturdy and virtually leak-proof, even under the most demanding sampling and shipping conditions.
  • Application: Preservation of exhaled breath samples for analysis by off-line SESI-HRMS: Demonstrates the utility of 5L Tedlar® SCV Gas Sampling Bags in preserving breath samples for secondary electrospray ionization-high resolution mass spectrometry, enhancing diagnostic capabilities in medical research (Sola-Martínez et al., 2023). Quantitative GC-TCD Measurements of Major Flatus Components: Utilizes 5L Tedlar® SCV Gas Sampling Bags for gas chromatography with a thermal conductivity detector to study dietary effects on flatus composition, contributing to better understanding of digestive processes (Freire et al., 2022). Quantification of volatile organic compounds by secondary electrospray ionization-high resolution mass spectrometry: Highlights the role of 5L Tedlar® SCV Gas Sampling Bags in the capture and quantification of volatile organic compounds, critical for environmental and chemical analysis (Liu et al., 2021). Application of a Microfluidic Gas-to-Liquid Interface for Extraction of Target Amphetamines and Precursors from Air Samples: Details the use of 5L Tedlar® SCV Gas Sampling Bags in microfluidic systems for precise air sampling and extraction, aiding forensic and environmental studies (Collins et al., 2020). Determination of linear and cyclic volatile methyl siloxanes in biogas and biomethane by solid-phase microextraction and gas chromatography-mass spectrometry: Discusses the effectiveness of 5L Tedlar® SCV Gas Sampling Bags in sampling for the analysis of complex gas mixtures, important for environmental monitoring and biogas quality control (Ghidotti et al., 2019).
  • Legal Information: ASTM is a registered trademark of American Society for Testing and Materials

Compare Similar Items

Show Difference

Img

Supelco

30274-U

5L w/ Thermogreen® LB-2 Septa...


product name:
5L Tedlar® SCV Gas Sampling Bag w/Thermogreen® LB-2 Septa,

material:
Tedlar® PVDF film

Quality Level:
100

Agency:
suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC)suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC)suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs))suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)suitable for NIOSH 3704 (Perchloroethylene)

description:
Screw Cap Valve (SCV)septum type: yes; Thermogreen® LB-2

packaging:
pkg of 10 bags

technique(s):
whole air sampling: suitable

W × L:
12 in. × 14 in.

maximum volume:
5 L

application(s):
air monitoringenvironmentalindustrial hygiene

Img

Sigma Aldrich

302759

1.0 M in diethyl ether...


product name:
__

material:
__

Quality Level:
100

Agency:
__

description:
__

packaging:
__

technique(s):
__

W × L:
__

maximum volume:
__

application(s):
__

Img

Fischer Scientific

3027596

Spherical mirrors for use with an o...


product name:
__

material:
__

Quality Level:
__

Agency:
__

description:
__

packaging:
__

technique(s):
__

W × L:
__

maximum volume:
__

application(s):
__

Img

Supelco

30276-U

10L w/ Thermogreen® LB-2 Septa...


product name:
10L Tedlar® SCV Gas Sampling Bag w/Thermogreen® LB-2 Septa,

material:
Tedlar® PVDF film

Quality Level:
100

Agency:
suitable for ASTM® D5504 (Sulfur Compounds in Natural Gas and Fuels by GC)suitable for EPA 18 (Gaseous Organic Compounds; VOCs by GC)suitable for EPA 40,TO-3,TO-15 (Volatile Organic Compounds (VOCs))suitable for EPA TO-12 (Non-Methane Organic Compounds (NMOC))suitable for EPA TO-14A (Volatile Organic Compounds (VOCs) by GC/MS)suitable for NIOSH 3704 (Perchloroethylene)

description:
Screw Cap Valve (SCV)septum type: yes; Thermogreen® LB-2

packaging:
pkg of 10 bags

technique(s):
whole air sampling: suitable

W × L:
__

maximum volume:
__

application(s):
air monitoringenvironmentalindustrial hygiene