S28542

OHAUS™ Explorer™ Semi-Micro Balances

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 S28542-Each-of-1 In Stock ₹ 6,31,261.68

S28542 - Each of 1

₹ 6,31,261.68

In Stock

Quantity

1

Base Price: ₹ 6,31,261.68

GST (18%): ₹ 1,13,627.102

Total Price: ₹ 7,44,888.782

Automation Interface

Standard connectivity: 1 USB host, 1 USB device, 1

Certifications/Compliance

Product Safety: CAN/CSA C22.2 61010-1, UL 61010-1,

Display Type

14.5 cm (5.7 in.) (Diagonal) Full-Color Touchscreen

Humidity Range

85% RH, non-condensing

Min. Sample Weight

Typical: 20mg, fine range (USP, u=0.10%, k=2); Opt

Stabilization Time

0.1 mg: ≤3 sec., 0.01 mg: ≤8 sec.

Temperature Range (Metric)

10°C to 30°C

Weighing Modes

g, mg, kg, ct ,gn, oz, ozt, lb, dwt, N, mom, tical

Height (Metric)

39.3 cm

Diameter (English) Outer Pan

3.1 in.

Electrical Requirements

AC Adapter Input: 100 to 240 VAC 50/60 Hz 0.6 A AC

Calibration

50g, 100g

Capacity

52 g, 120 g

Readability

0.01, 0.1 mg

Includes

Without automatic door

Model

EX125D

Temperature Range (English)

50°F to 86°F

Type

Semi Micro Balance

Width (Metric)

23 cm

Depth (Metric)

35 cm

Diameter (Metric) Outer Pan

80 mm

Related Products

Img

Fischer Scientific

S28543

--

Img

Fischer Scientific

S28544

--

Img

Fischer Scientific

7070815

Balances built for accurate, sophis...

Img

Fischer Scientific

02-112-236

--

Img

Fischer Scientific

S28572

--

Img

Fischer Scientific

S28577

--

Img

Fischer Scientific

S28593

--

Img

Fischer Scientific

S28621

--

Description

  • AutoCal™ internal calibration feature utilizes two internal weights to perform a linear calibration to minimize weighing errors and ensure accurate measurements Intuitive software powered by SmarText™ 2.0 Ultra-fast stabilization time (0.1mg: ≤3 sec., 0.01mg: ≤8 sec.) and audible stability alert increases laboratory efficiency Icon-based color touchscreen display provides tactile feedback and operates in the same manner as a smart phone or tablet computer Four programmable touchless sensors allow the operator to perform common functions and commands with a swipe of the hand USB host port provides the capability of using a USB extension cable to directly transfer the data to a flash drive Memory library includes space for up to 99 items, and a 10 recipe library for formulation mode User manager function provides profiles for one administrator and five additional users, allowing multiple users to utilize the same balance without compromising past results recorded on the balance Modular design in which the base and display can be separated to allow the balance to fit ideally on the lab bench Automatic door feature (available on certain models) allows access to weighing chamber without the need to touch the draftshield door; they minimize vibrations caused by manual operation Built-in ionizer, included in Explorer automatic door models, generates bipolar ions continuously from positive and negative discharge electrodes and directs the ionized air onto the charged body to eliminate static electricity Other advanced features include: Below minimum sample weight indicator, real time clock for GLP/GMP data collection, true type printing for SQC and pipette adjustment Specifications: Capacity: 52g to 220g Calibration: Standard AutoCal, AutoCal on Δ1.5° temperature change, 3 hours Weighing Units: g, mg, kg, ct ,gn, oz, ozt, lb, dwt, N, mom, tical, msg, tola, baht, Hong Kong Tael, Singapore Tael, Taiwan Tael, Custom Units 1, Custom Unit 2, Custom Unit 3 Applications: Weighing, Parts Counting, Percent Weighing, Checkweighing, Dynamic Weighing, Filling, Totalization, Formulation, Differential Weighing, Peak Hold, Density Determination, Pipette Adjustment, Statistical Quality Control Stabilization Time: 0.1mg: ≤3 sec., 0.01mg: ≤8 sec
  • Sensitivity Temp
  • Drift: 0.50ppm/°C Min-Weight (typical): 20mg, fine range (USP, u=0.10%, k=2) Min-Weight (optimal); 9.0mg, fine range (USP, u=0.10%, k=2) SRP≤41d Display: 14.5cm (5.7 in.) (diagonal) Full-Color touch screen Interface: Standard connectivity: 1 USB host, 1 USB device, 1 RS232; Optional connectivity: 2nd RS232, Ethernet Working Temperature: 10°to 30°C (50° to 86°F) Humidity: 85% RH, non-condensing Storage Conditions: 10° to 60°C (-14° to +140°F) at 10% to 90% relative humidity, non-condensing Power Supply: AC Adapter Input: 100 to 240 VAC 50/60Hz, 0.6A, AC Adapter Output: 12 VDC 1.5A Pan Dia.: 80mm (3.1 in.) Dimensions (D x W x H): 35 x 23 x 39.3cm (13.8 x 9 x 15.5 in.) Certifications Product Safety: CAN/CSA C22.2 61010-1, UL 61010-1, IEC 61010-1 Compliance Electromagnetic Compatibility: FCC Part 15 (Class A), Industry Canada ICES-001 (Class A), IEC 61326-1, (Class B emissions, Industrial immunity)

Compare Similar Items

Show Difference

Img

Fischer Scientific

S28542

--


Automation Interface:
Standard connectivity: 1 USB host, 1 USB device, 1

Certifications/Compliance:
Product Safety: CAN/CSA C22.2 61010-1, UL 61010-1,

Display Type:
14.5 cm (5.7 in.) (Diagonal) Full-Color Touchscreen

Humidity Range:
85% RH, non-condensing

Min. Sample Weight:
Typical: 20mg, fine range (USP, u=0.10%, k=2); Opt

Stabilization Time:
0.1 mg: ≤3 sec., 0.01 mg: ≤8 sec.

Temperature Range (Metric):
10°C to 30°C

Weighing Modes:
g, mg, kg, ct ,gn, oz, ozt, lb, dwt, N, mom, tical

Height (Metric):
39.3 cm

Diameter (English) Outer Pan:
3.1 in.

Electrical Requirements:
AC Adapter Input: 100 to 240 VAC 50/60 Hz 0.6 A AC

Calibration:
50g, 100g

Capacity:
52 g, 120 g

Readability:
0.01, 0.1 mg

Includes:
Without automatic door

Model:
EX125D

Temperature Range (English):
50°F to 86°F

Type:
Semi Micro Balance

Width (Metric):
23 cm

Depth (Metric):
35 cm

Diameter (Metric) Outer Pan:
80 mm

Img

Fischer Scientific

S28543

--


Automation Interface:
Standard connectivity: 1 USB host, 1 USB device, 1

Certifications/Compliance:
Product Safety: CAN/CSA C22.2 61010-1, UL 61010-1,

Display Type:
14.5 cm (5.7 in.) (Diagonal) Full-Color Touchscreen

Humidity Range:
85% RH, non-condensing

Min. Sample Weight:
Typical: 20mg, fine range (USP, u=0.10%, k=2); Opt

Stabilization Time:
0.1 mg: ≤3 sec., 0.01 mg: ≤8 sec.

Temperature Range (Metric):
10°C to 30°C

Weighing Modes:
g, mg, kg, ct ,gn, oz, ozt, lb, dwt, N, mom, tical

Height (Metric):
39.3 cm

Diameter (English) Outer Pan:
3.1 in.

Electrical Requirements:
AC Adapter Input: 100 to 240 VAC 50/60 Hz 0.6 A AC

Calibration:
50g, 100g

Capacity:
120 g

Readability:
0.01 mg

Includes:
Without automatic door

Model:
EX125

Temperature Range (English):
50°F to 86°F

Type:
Semi Micro Balance

Width (Metric):
23 cm

Depth (Metric):
35 cm

Diameter (Metric) Outer Pan:
80 mm

Img

Fischer Scientific

S28544

--


Automation Interface:
Standard connectivity: 1 USB host, 1 USB device, 1

Certifications/Compliance:
Product Safety: CAN/CSA C22.2 61010-1, UL 61010-1,

Display Type:
14.5 cm (5.7 in.) (Diagonal) Full-Color Touchscreen

Humidity Range:
85% RH, non-condensing

Min. Sample Weight:
Typical: 20mg, fine range (USP, u=0.10%, k=2); Opt

Stabilization Time:
0.1 mg: ≤3 sec., 0.01 mg: ≤8 sec.

Temperature Range (Metric):
10°C to 30°C

Weighing Modes:
g, mg, kg, ct ,gn, oz, ozt, lb, dwt, N, mom, tical

Height (Metric):
39.3 cm

Diameter (English) Outer Pan:
3.1 in.

Electrical Requirements:
AC Adapter Input: 100 to 240 VAC 50/60 Hz 0.6 A AC

Calibration:
100g, 150g, 200g

Capacity:
120 g, 220 g

Readability:
0.01, 0.1 mg

Includes:
With standard automatic door

Model:
EX225D/AD

Temperature Range (English):
50°F to 86°F

Type:
Semi Micro Balance

Width (Metric):
23 cm

Depth (Metric):
35 cm

Diameter (Metric) Outer Pan:
80 mm

Img

Fischer Scientific

S28546

--


Automation Interface:
Touchscreen

Certifications/Compliance:
NIST, AM-5847, IEC/EN 61010-1:2010, CAN/CSA-C22.2,

Display Type:
Color Graphic

Humidity Range:
__

Min. Sample Weight:
__

Stabilization Time:
≤2 sec.

Temperature Range (Metric):
10°C to 30°C

Weighing Modes:
__

Height (Metric):
35 cm

Diameter (English) Outer Pan:
__

Electrical Requirements:
100/240 V 50/60 Hz

Calibration:
__

Capacity:
120 g

Readability:
0.0001 g

Includes:
Automatic draft shield 3 door, AutoCal™ inte

Model:
EX124/AD

Temperature Range (English):
50°F to 86°F

Type:
Analytical Balance

Width (Metric):
23 cm

Depth (Metric):
39.3 cm

Diameter (Metric) Outer Pan:
__