L34984

Invitrogen™ LIVE/DEAD™ Fixable Orange (602) Viability Kit, for 561 nm excitation

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Pack of 200 L34984-Pack-of-200 In Stock ₹ 26,352.48

L34984 - Pack of 200

₹ 26,352.48

In Stock

Quantity

1

Base Price: ₹ 26,352.48

GST (18%): ₹ 4,743.446

Total Price: ₹ 31,095.926

Quantity

200 Assays

Description

LIVE/DEAD™ Fixable Orange (602) Viability Kit, for 561 nm excitation

For Use With (Application)

Flow Cytometry

Format

Tubes

Content And Storage

Contains 5 vials of LIVE/DEAD fixable dead cell stain and 500 μL DMSO.Store at -20°C.

Excitation/Emission

578/602 nm

Solubility

DMSO (Dimethylsulfoxide)

Product Line

LIVE/DEAD™

Detection Method

Fluorescence

Conjugate

LIVE/DEAD Fixable Orange (602) Cell Stain

Product Type

Cell Viability Kit

Color

Orange

Compatible Cells

Eukaryotic Cells

Flow Cytometer Laser Lines

561 nm

Shipping Condition

Room Temperature

For Use With (Equipment)

Flow Cytometer

Related Products

Img

Fischer Scientific

L34983

--

Img

Fischer Scientific

L34985

--

Img

Fischer Scientific

L34977

--

Img

Fischer Scientific

L34978

--

Img

Fischer Scientific

L34990

--

Img

Fischer Scientific

L34989

--

Img

Fischer Scientific

L34987

--

Img

Fischer Scientific

L34986

--

Description

  • Fixable viability kits allow for clear determination of live and dead cells, enabling more precise analysis with both conventional and spectral flow cytometry Cells labeled with LIVE/DEAD Fixable viability dyes can be washed, fixed, permeabilized, and stained for intracellular antigens while maintaining distinct live and dead cell populations The narrow and unique emission spectra are ideal for expanding high-parameter flow cytometry experiments Designed to provide a bright signal with minimal overlap into adjacent channels, simplifying spectral compensation Since live and dead cells can be discriminated using a single flow cytometer channel, these viability dyes are an ideal choice for multi-color experiments
  • Their unique spectral fingerprints are a valuable addition to spectral flow cytometry experiments Dyes have been conveniently packaged in single-use vials to help ensure dye stability and performance over time Dissolve the dye in the included anhydrous DMSO and use immediately, or store at -20°C, avoiding freeze-thaw cycles The LIVE/DEAD Fixable Dead Cell Stain Sampler Kit provides one vial (40 assays) of each of eight available dead cell stains

Compare Similar Items

Show Difference

Img

Fischer Scientific

L34984

--


Quantity:
200 Assays

Description:
LIVE/DEAD™ Fixable Orange (602) Viability Kit, for 561 nm excitation

For Use With (Application):
Flow Cytometry

Format:
Tubes

Content And Storage:
Contains 5 vials of LIVE/DEAD fixable dead cell stain and 500 μL DMSO.Store at -20°C.

Excitation/Emission:
578/602 nm

Solubility:
DMSO (Dimethylsulfoxide)

Product Line:
LIVE/DEAD™

Detection Method:
Fluorescence

Conjugate:
LIVE/DEAD Fixable Orange (602) Cell Stain

Product Type:
Cell Viability Kit

Color:
Orange

Compatible Cells:
Eukaryotic Cells

Flow Cytometer Laser Lines:
561 nm

Shipping Condition:
Room Temperature

For Use With (Equipment):
Flow Cytometer

Img

Fischer Scientific

L34985

--


Quantity:
400 Assays

Description:
LIVE/DEAD™ Fixable Orange (602) Viability Kit, for 561 nm excitation

For Use With (Application):
Flow Cytometry

Format:
Tubes

Content And Storage:
Contains 10 vials of LIVE/DEAD fixable dead cell stain and 2 vials of 500 μL DMSO.Store at -20°C.

Excitation/Emission:
578/602 nm

Solubility:
DMSO (Dimethylsulfoxide)

Product Line:
LIVE/DEAD™

Detection Method:
Fluorescence

Conjugate:
LIVE/DEAD Fixable Orange (602) Cell Stain

Product Type:
__

Color:
Orange

Compatible Cells:
Eukaryotic Cells

Flow Cytometer Laser Lines:
561 nm

Shipping Condition:
Room Temperature

For Use With (Equipment):
Flow Cytometer

Img

Fischer Scientific

L34986

--


Quantity:
80 Assays

Description:
LIVE/DEAD™ Fixable Scarlet (723) Viability Kit, for 633 nm excitation

For Use With (Application):
Flow Cytometry

Format:
Tube(s)

Content And Storage:
Contains 2 vials of LIVE/DEAD fixable dead cell stain and 500 μL DMSO.Store at -20°C.

Excitation/Emission:
702/723 nm

Solubility:
DMSO (Dimethylsulfoxide)

Product Line:
LIVE/DEAD™

Detection Method:
Fluorescence

Conjugate:
LIVE/DEAD Fixable Scarlet (723) Cell Stain

Product Type:
Cell Viability Kit

Color:
Scarlet

Compatible Cells:
Eukaryotic Cells

Flow Cytometer Laser Lines:
633 nm

Shipping Condition:
Room Temperature

For Use With (Equipment):
Flow Cytometer

Img

Fischer Scientific

L34987

--


Quantity:
200 Assays

Description:
LIVE/DEAD™ Fixable Scarlet (723) Viability Kit, for 633 nm excitation

For Use With (Application):
Flow Cytometry

Format:
Tubes

Content And Storage:
Contains 5 vials of LIVE/DEAD fixable dead cell stain and 500 μL DMSO.Store at -20°C.

Excitation/Emission:
702/723 nm

Solubility:
DMSO (Dimethylsulfoxide)

Product Line:
LIVE/DEAD™

Detection Method:
Fluorescence

Conjugate:
LIVE/DEAD Fixable Scarlet (723) Cell Stain

Product Type:
Cell Viability Kit

Color:
Scarlet

Compatible Cells:
Eukaryotic Cells

Flow Cytometer Laser Lines:
633 nm

Shipping Condition:
Room Temperature

For Use With (Equipment):
Flow Cytometer