NS220

Neurite Outgrowth Assay Kit (3 µm)

The NS220 Neurite Outgrowth Assay Kit (3 µm) is based on the use of Millicell cell culture inserts (chambers) containing a permeable membrane with 3-μm pores at the base.

Manufacturer: Sigma Aldrich

Select a Size

Pack Size SKU Availability Price
12 ASSAYS NS220-12-ASSAYS In Stock ₹ 47,770.00

NS220 - 12 ASSAYS

₹ 47,770.00

In Stock

Quantity

1

Base Price: ₹ 47,770.00

GST (18%): ₹ 8,598.60

Total Price: ₹ 56,368.60

Quality Level

100

species reactivity (predicted by homology)

all

manufacturer/tradename

Chemicon®

technique(s)

cell based assay: suitable

detection method

colorimetric

shipped in

wet ice

Related Products

Img

Sigma Aldrich

NS225

The NS225 Neurite Outgrowth Assay K...

Img

Sigma Aldrich

ECM210

This QCM Endothelial Cell Invasion ...

Img

Sigma Aldrich

ECM550

The CHEMICON Cell Invasion Assay Ki...

Img

Sigma Aldrich

ECM551

The Cell Invasion Assay Kit kuses a...

Img

Sigma Aldrich

ECM582

The QCM Haptotaxis Cell Migration A...

Img

Sigma Aldrich

ECM200

--

Img

Sigma Aldrich

ECM508

The QCM 24-well Migration Assay is ...

Img

Sigma Aldrich

ECM506

This 3 um QCM Chemotaxis Assay 24-w...

Description

  • General description: Application CHEMICON′s NS220 Neurite Outgrowth Assay Kit (3 µm) utilizes microporous tissue culture insert technology from Millipore and is based on the use of Millicell cell culture inserts (chambers) containing a permeable membrane with 3-μm pores at the base. The Millicell inserts utilized in this kit are appropriate for cells projecting neurites of up to 3 µm diameter, e.g. N1E-115 cells [Abe et al., 2003], Dorsal Root Ganglia and Schwann cells [Windebank et al., 1985]. The inserts are designed to fit into a receiver vessel, which when in use contains differentiation media in contact with the bottom of the insert membrane. The permeable membranes allow for discrimination between neurites and cell bodies, as projecting neurites will pass easily through the pores but cell bodies will not. Therefore, by inducing neurites to traverse these membrane pores, a purified population of neurites is located on the underside of the membrane, distal to the surface on which neural cell bodies are deposited. The assay is a simple, efficient, and versatile system for the quantitative determination of compounds that influence neurite formation and repulsion. With this system, it is possible to screen numerous biological and pharmacological agents simultaneously, directly evaluate adhesion and guidance receptor functions responsible for neurite extension and repulsion, as well as analyze gene function in transfected cells. The microporous filter allows for biochemical separation and purification of neurites and cell bodies for detailed molecular analysis of protein expression, signal transduction processes and identification of drug targets that regulate neurite outgrowth or retraction processes. Reagents and materials supplied in the NS220 Neurite Outgrowth Assay Kit are sufficient for 12 tests. Note: the 3 µm pore size inserts in this kit are unsuitable for use with PC12 cells. Due to the relatively small diameter of PC12 cell bodies [Abe et al., 2003], some of these cells may pass though 3 µm pores and obscure the results. Chemicon′s NS225 Neurite Outgrowth Assay Kit (1 µm) has been specifically designed for and validated with PC12 cells.
  • Application: The NS220 Neurite Outgrowth Assay Kit (3 µm) is based on the use of Millicell cell culture inserts (chambers) containing a permeable membrane with 3-μm pores at the base.
  • Components: 1. Neurite Outgrowth Plate Assembly, 3 μm: (Part No. 2007256) 1 x 24-well plate containing 12 x Millicell hanging inserts with 3 μm pore size membranes.2. Neurite Stain Solution: (Part No. 90242) One 20 mL bottle.3. Neurite Stain Extraction Buffer: (Part No. 90243) One 20 mL bottle.4. Neurite Outgrowth Assay Plate: (Part No. 2007255) Two 24-well plates.5. Cotton Swabs: (Part No. 10202) 50 swabs.6. Forceps: (Part No. 10203) One each.
  • Storage and Stability: When stored at 2-8° C, the kit components are stable up to the expiration date. Do not freeze or expose to elevated temperatures. Discard any remaining reagents after the expiration date.
  • Legal Information: CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
  • Disclaimer: Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

SAFETY INFORMATION

Pictograms

GHS02,GHS07

Signal Word

Danger

Hazard Statements

H225,H319

Precautionary Statements

P210 - P233 - P240 - P241 - P242 - P305 + P351 + P338

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2

WGK

WGK 1

Compare Similar Items

Show Difference

Img

Sigma Aldrich

NS220

The NS220 Neurite Outgrowth Assay K...


Quality Level:
100

species reactivity (predicted by homology):
all

manufacturer/tradename:
Chemicon®

technique(s):
cell based assay: suitable

detection method:
colorimetric

shipped in:
wet ice

Img

Sigma Aldrich

NS225

The NS225 Neurite Outgrowth Assay K...


Quality Level:
100

species reactivity (predicted by homology):
all

manufacturer/tradename:
Chemicon®

technique(s):
cell based assay: suitable

detection method:
colorimetric

shipped in:
wet ice

Img

Millipore

NSRULER-10050

--


Quality Level:
__

species reactivity (predicted by homology):
__

manufacturer/tradename:
NovaSeptum®

technique(s):
__

detection method:
__

shipped in:
__

Img

Millipore

NSRULER-10100

--


Quality Level:
__

species reactivity (predicted by homology):
__

manufacturer/tradename:
NovaSeptum®

technique(s):
__

detection method:
__

shipped in:
__