10-269-134

Invitrogen™ EVOS™ Onstage Incubator (OSI-2)

Manufacturer: Invitrogen™

Select a Size

Pack Size SKU Availability Price
Each of 1 10-269-134-Each-of-1 In Stock ₹ 20,55,236.76

10-269-134 - Each of 1

₹ 20,55,236.76

In Stock

Quantity

1

Base Price: ₹ 20,55,236.76

GST (18%): ₹ 3,69,942.617

Total Price: ₹ 24,25,179.377

Type

Onstage Incubator

For Use With (Application)

Time-lapse imaging

Holds

Slides, chambered slides, chambered coverglass, multiwell plates, petri dishes, T-25 flasks, and T-75 flasks

Temperature Range (Metric)

Ambient to 40°C (± 0.1°C)

Height (Metric)

23 cm (Control Unit)4.1 cm (Environmental Unit)

Length (Metric)

45 cm (Control Unit)21 cm (Environmental Unit)

Weight (Metric)

6.7 kg (Control Unit)0.73 kg (Environmental Unit)

Width (Metric)

21 cm (Control Unit)23 cm (Environmental Unit)

Quantity

Each

Frequency

50/60 Hz

Product Line

EVOS

For Use With (Equipment)

EVOS™ M5000 Imaging System, EVOS™ M7000 Imaging System

Relative Humidity

70 to 90% at 37°C to 40°C

Height (English)

9 in. (Control Unit)1.6 in. (Environmental Unit)

Length (English)

18 in. (Control Unit)11 in. (Environmental Unit)

Weight (English)

15 lb. (Control Unit)1.6 lb. (Environmental Unit)

Width (English)

8.3 in. (Control Unit)9 in. (Environmental Unit)

Content And Storage

• Stagetop Environmental Chamber• Control Unit• Master Stage Plate (AMEPVH106)• Light shield and light shield cover• Sensor data cable with 6-pin connector• Cable, USB 2.0 A-to-B, 180 cm (6 ft)• Heated hose with temperature control, 180 cm (6 ft; AMEP4728)• Gas line, 1/8 in. ID, 1/4. OD (AMEP4732)• Push-to-connect gas line adaptor, 1/4 in. NPT male (3 each)• Standard-head open-end wrench• Hex screw driver (2 mm)• Power cord, Type A (North America)NOTE: A country-specific power cord must be ordered separately in regions not using the Type A power plug

Shipping Condition

Room Temperature

Voltage

100/240 V

Related Products

Img

Invitrogen™

AMF3000

--

Img

Invitrogen™

AMF5000SV

--

Img

Invitrogen™

12-563-631

--

Img

Invitrogen™

12-563-649

--

Img

Fischer Scientific

BTCYT5FAW

--

Img

Fischer Scientific

BTCYT5FW

--

Img

Fischer Scientific

BTCYT5MPW

--

Img

Invitrogen™

12-562-751

--

Description

  • The second generation EVOS Onstage Incubator (OSI-2) is designed to work seamlessly with the EVOS M5000 and EVOS M7000 imaging systems and provides precise control of temperature, humidity, and gas concentration (O2, CO2, N2), allowing the capture of images from the same sample over long periods of time and recording of time lapse movies under physiological and non-physiological conditions
  • For added convenience, the OSI-2 contains an on board air compressor, eliminating the need for a separate air tank
  • Environmental settings and image acquisition parameters are all seamlessly integrated into the microscope user interface, creating a high-performance inverted imaging system with excellent flexibility, ease of use, and superb optical performance for demanding live cell time-lapse imaging experiments
  • The EVOS Onstage Incubator (OSI-2) offers these important advantages: • Fully integrated environmental chamber for live cell time-lapse imaging • Precise maintenance of physiological or non-physiological conditions for the duration of the time-lapse experiment • Intuitive user-interface for setting environmental conditions and image acquisition parameters • Small footprint, robust build, and workflow-enhancing design elements • Choice of a wide range of onstage incubator-compatible vessel holders • Quiet, on-board air compressor Fully integrated environmental control system The OSI-2 consists of an environmental control unit and an environmental chamber precision-tooled for the automated X-Y stage on the EVOS M7000 system (Cat
  • No
  • AMF7000)
  • The stage plate (link to new PDP AMEPVH106) that ships with the OSI-2 is also compatible with the semi-automated EVOS M5000 system (Cat
  • No
  • AMF5000)
  • A small, separate control unit provides power, humidity and temperature control, and gas (air or air-CO 2 premix, CO 2 , and N 2 for O 2 displacement in hypoxia experiments)
  • Unlike many other systems that require separate software modules or control units, the OSI-2 is operated through the user interface of the EVOS M5000 and M7000 systems
  • Following a simple installation, the incubator is automatically recognized by the imaging software and ready for use
  • Flexible and precise environmental control When performing live-cell imaging studies, such as cell proliferation, cell cycle, stem cell differentiation, migration, membrane, and organelle dynamics studies, it is essential to maintain environmental control
  • Shifts in temperature of even few degrees can have profound effects on dynamic cellular events, as can changes in CO 2 or oxygen concentrations
  • The ability to maintain tight temperature control helps maintain cell function and reduces the risk of biological temperature-related artifacts
  • It also minimizes thermal contractions or expansions that may cause focus instability or drift
  • To enable studies of cells under hypoxic conditions, the system has three gas line ports
  • By using N2 it is possible to create hypoxia by setting the oxygen sensor to the desired level
  • Operating ranges and levels Temperature range: ambient to 40°C (+/- 0.1°C) Relative humidity range: 70–90% at 37-40°C CO 2 range: 0–20% O 2 range: 0% to ambient Air-compressor decibel level: 45 Db (with cover); 48 Db (without cover)

Compare Similar Items

Show Difference

Img

Invitrogen™

10-269-134

--


Type:
Onstage Incubator

For Use With (Application):
Time-lapse imaging

Holds:
Slides, chambered slides, chambered coverglass, multiwell plates, petri dishes, T-25 flasks, and T-75 flasks

Temperature Range (Metric):
Ambient to 40°C (± 0.1°C)

Height (Metric):
23 cm (Control Unit)4.1 cm (Environmental Unit)

Length (Metric):
45 cm (Control Unit)21 cm (Environmental Unit)

Weight (Metric):
6.7 kg (Control Unit)0.73 kg (Environmental Unit)

Width (Metric):
21 cm (Control Unit)23 cm (Environmental Unit)

Quantity:
Each

Frequency:
50/60 Hz

Product Line:
EVOS

For Use With (Equipment):
EVOS™ M5000 Imaging System, EVOS™ M7000 Imaging System

Relative Humidity:
70 to 90% at 37°C to 40°C

Height (English):
9 in. (Control Unit)1.6 in. (Environmental Unit)

Length (English):
18 in. (Control Unit)11 in. (Environmental Unit)

Weight (English):
15 lb. (Control Unit)1.6 lb. (Environmental Unit)

Width (English):
8.3 in. (Control Unit)9 in. (Environmental Unit)

Content And Storage:
• Stagetop Environmental Chamber• Control Unit• Master Stage Plate (AMEPVH106)• Light shield and light shield cover• Sensor data cable with 6-pin connector• Cable, USB 2.0 A-to-B, 180 cm (6 ft)• Heated hose with temperature control, 180 cm (6 ft; AMEP4728)• Gas line, 1/8 in. ID, 1/4. OD (AMEP4732)• Push-to-connect gas line adaptor, 1/4 in. NPT male (3 each)• Standard-head open-end wrench• Hex screw driver (2 mm)• Power cord, Type A (North America)NOTE: A country-specific power cord must be ordered separately in regions not using the Type A power plug

Shipping Condition:
Room Temperature

Voltage:
100/240 V

Img

Fischer Scientific

10-269-60

--


Type:
__

For Use With (Application):
__

Holds:
__

Temperature Range (Metric):
__

Height (Metric):
__

Length (Metric):
__

Weight (Metric):
30 kg

Width (Metric):
__

Quantity:
__

Frequency:
60 Hz

Product Line:
__

For Use With (Equipment):
__

Relative Humidity:
__

Height (English):
__

Length (English):
__

Weight (English):
66 lb.

Width (English):
__

Content And Storage:
__

Shipping Condition:
__

Voltage:
115 V

Img

Fischer Scientific

10-269-602

--


Type:
Benchtop

For Use With (Application):
__

Holds:
4 Standard 96-well Plate or 2 Deep-well Plate

Temperature Range (Metric):
-4°C to +100°C

Height (Metric):
42.2 cm

Length (Metric):
__

Weight (Metric):
49 kg

Width (Metric):
36.3 cm

Quantity:
__

Frequency:
60 Hz

Product Line:
__

For Use With (Equipment):
__

Relative Humidity:
__

Height (English):
16.6 in.

Length (English):
21.7 in.

Weight (English):
108 lb.

Width (English):
14.3 in.

Content And Storage:
__

Shipping Condition:
__

Voltage:
115 V

Img

Labconco™

10-269-64

--


Type:
Flask Filter

For Use With (Application):
prevents partial loss of product during freeze drying

Holds:
__

Temperature Range (Metric):
__

Height (Metric):
__

Length (Metric):
__

Weight (Metric):
__

Width (Metric):
__

Quantity:
1000/Pk.

Frequency:
__

Product Line:
__

For Use With (Equipment):
__

Relative Humidity:
__

Height (English):
__

Length (English):
__

Weight (English):
__

Width (English):
__

Content And Storage:
__

Shipping Condition:
__

Voltage:
__