26-091-3370

Thermo Scientific™ TraceGOLD TG-1301MS GC Columns

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

USP Type

G43

Max. Temperature

260/280°C

Diameter (Metric)

0.53 mm

Film Thickness

1.5 μm

Polarity

Mid-Polar

Stationary Phase

TraceGOLD™ TG-1301 MS

Diameter (Metric) Inner

0.53 mm

For Use With (Application)

ECD and GC/MS for Alcohols, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents

Length (Metric)

60 m

Description

1.5um thickness; 0.53mm ID; 60m length

Related Products

Img

Fischer Scientific

26-091-3100

--

Img

Fischer Scientific

26-091-3360

--

Img

Fischer Scientific

26-091-2370

--

Img

Fischer Scientific

26-091-3340

--

Img

Fischer Scientific

26-091-1560

--

Img

Fischer Scientific

26-091-2250

--

Img

Fischer Scientific

26-091-4900

--

Img

Fischer Scientific

26-091-2860

--

Description

  • Thermo Scientific™ TraceGOLD TG-1301MS GC Columns provide low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS
  • Low to mid-polarity phase, 6% cyanopropylphenyl/94% dimethyl polysiloxane Long lifetime Excellent inertness Equivalent to USP G43 phase Similar to: Rtx-1301, DB-1301, BP-624, HP-1301, HP-624, SPB-1301, SPB-624, VP-1301, BF-624ms, CP-1301, CP-Select 624 CB Recommended for: Alcohols Volatile organics Oxygenates Residual solvents

Compare Similar Items

Show Difference

Img

Fischer Scientific

26-091-3370

--


USP Type:
G43

Max. Temperature:
260/280°C

Diameter (Metric):
0.53 mm

Film Thickness:
1.5 μm

Polarity:
Mid-Polar

Stationary Phase:
TraceGOLD™ TG-1301 MS

Diameter (Metric) Inner:
0.53 mm

For Use With (Application):
ECD and GC/MS for Alcohols, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents

Length (Metric):
60 m

Description:
1.5um thickness; 0.53mm ID; 60m length

Img

Fischer Scientific

26-091-3390

--


USP Type:
G43

Max. Temperature:
260/280°C

Diameter (Metric):
0.32 mm

Film Thickness:
1.8 μm

Polarity:
Mid-Polar

Stationary Phase:
TraceGOLD™ TG-1301 MS

Diameter (Metric) Inner:
0.32 mm

For Use With (Application):
Residual Solvents Analysis, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents

Length (Metric):
30 m

Description:
1.8 um Thickness; 0.32 mm ID; 30 m Length

Img

Fischer Scientific

26-091-3410

--


USP Type:
G43

Max. Temperature:
260/280°C

Diameter (Metric):
0.32 mm

Film Thickness:
1.8 μm

Polarity:
Mid-Polar

Stationary Phase:
TraceGOLD™ TG-1301 MS

Diameter (Metric) Inner:
0.32 mm

For Use With (Application):
Residual Solvents Analysis, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents

Length (Metric):
60 m

Description:
1.8 um Thickness; 0.32 mm ID; 60 m Length

Img

Fischer Scientific

26-091-3840

--


USP Type:
G43

Max. Temperature:
260/280°C

Diameter (Metric):
0.53 mm

Film Thickness:
3 μm

Polarity:
Mid-Polar

Stationary Phase:
TraceGOLD™ TG-1301 MS

Diameter (Metric) Inner:
0.53 mm

For Use With (Application):
ECD and GC/MS for Alcohols, ECD and GC/MS for Volatile Organics, ECD and GC/MS for Oxygenates, ECD and GC/MS for Residual Solvents

Length (Metric):
15 m

Description:
3um thickness; 0.53mm ID; 15m length