13-622-102

Hamilton™ PRP™-C18 Reversed-Phase HPLC Columns: Stainless Steel

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 13-622-102-Each-of-1 In Stock ₹ 66,565.68

13-622-102 - Each of 1

₹ 66,565.68

In Stock

Quantity

1

Base Price: ₹ 66,565.68

GST (18%): ₹ 11,981.822

Total Price: ₹ 78,547.502

Diameter (Metric)

2.1 mm

For Use With

LC/MS Separation

Max. Pressure

5000 psi (345 bar)

Particle Size

5 μm

Pore Size

100 Å

USP Type

L21

Packing Material

Polymer

Phase

Reversed Phase

Type

Column

Film Thickness

5 μm

Length (Metric)

150 mm

Mobile Phase Compatibility

pH 1 to 13, 0 to 100% aqueous, organic modifier

pH

1 to 13

Temperature

5°C to 85°C

Stationary Phase

PRP-C18

Column Type

Reversed Phase

Material

Stainless Steel

Related Products

Img

Fischer Scientific

13-622-100

--

Img

Fischer Scientific

13-622-104

--

Img

Fischer Scientific

13-622-106

--

Img

Fischer Scientific

13-622-110

--

Img

Fischer Scientific

13-622-112

--

Img

Fischer Scientific

13-622-250

--

Img

Fischer Scientific

14-816-1

--

Img

Fischer Scientific

14-816-57

--

Description

  • Rigid stationary phase has excellent mechanical and thermal stability, does not experience shrinking or swelling, and is completely inert to most conditions commonly encountered in reversed-phase chromatography
  • Benefits & Features pH stable from 1 to 14 Temperature stability above 100°C Unique bonding of C18 to a polymer support LC/MS applications, synthesized DNA, and small molecules Excellent durability (stable to any concentration of water or organic solvent) Custom hardware dimensions available Analytical and semi-prep/preparative guard columns available Hamilton PRP-C18 Column is a durable and effective column for general purpose HPLC and is especially well-suited for specialized applications in the clinical, pharmaceutical, environmental, food, forensics, and life sciences industries
  • Advantages of PRP-C18 Polymeric Reversed-Phase Columns Reproducibility Hamilton PRP-C18 reversed-phase columns are ideal for applications that require a high degree of column-to-column and batch to batch consistency (e.g., quality assurance, clinical trials)
  • Because of the unique polymer bonding of the C18 to the PS-DVB support, PRP-C18 columns maintain their performance characteristics longer than many traditional C8 or C18 silica columns
  • While many column manufacturers rely on other sources for their raw silica support, Hamilton manufactures its PRP-C18 support, assuring a consistent supply of PRP-C18 columns
  • Long Life (Excellent Durability) Hamilton PRP-C18 is a new column designed to provide high-efficiency reversed-phase separations over an extended column life in nearly any mobile phase or pH
  • The rigid stationary phase has excellent mechanical and thermal stability (>100°C), is pressure stable up to 5,000 psi, is highly cross-linked to prevent shrinkage or swelling (common in other polymeric columns) and is completely inert to most conditions commonly encountered in reversed-phase chromatography
  • The PRP-C18 demonstrates pH stability even after prolonged exposure to concentrated (1 molar) NaOH and H 2 SO 4 with no measurable deterioration in performance, making restoration to original performance readily achievable where it is not possible with traditional HPLC columns
  • PRP-C18 columns last 3 to 4 times longer than silica-based columns under most conditions due to the chemical durability of the base support.

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-622-102

--


Diameter (Metric):
2.1 mm

For Use With:
LC/MS Separation

Max. Pressure:
5000 psi (345 bar)

Particle Size:
5 μm

Pore Size:
100 Å

USP Type:
L21

Packing Material:
Polymer

Phase:
Reversed Phase

Type:
Column

Film Thickness:
5 μm

Length (Metric):
150 mm

Mobile Phase Compatibility:
pH 1 to 13, 0 to 100% aqueous, organic modifier

pH:
1 to 13

Temperature:
5°C to 85°C

Stationary Phase:
PRP-C18

Column Type:
Reversed Phase

Material:
Stainless Steel

Img

Fischer Scientific

13-622-104

--


Diameter (Metric):
2.1 mm

For Use With:
LC/MS Separation

Max. Pressure:
5000 psi (345 bar)

Particle Size:
5 μm

Pore Size:
100 Å

USP Type:
L21

Packing Material:
Polymer

Phase:
Reversed Phase

Type:
Column

Film Thickness:
5 μm

Length (Metric):
250 mm

Mobile Phase Compatibility:
pH 1 to 13, 0 to 100% aqueous, organic modifier

pH:
1 to 13

Temperature:
5°C to 85°C

Stationary Phase:
PRP-C18

Column Type:
Reversed Phase

Material:
Stainless Steel

Img

Fischer Scientific

13-622-106

--


Diameter (Metric):
4.6 mm

For Use With:
LC/MS Separation

Max. Pressure:
5000 psi (345 bar)

Particle Size:
5 μm

Pore Size:
100 Å

USP Type:
L21

Packing Material:
Polymer

Phase:
Reversed Phase

Type:
Column

Film Thickness:
5 μm

Length (Metric):
50 mm

Mobile Phase Compatibility:
pH 1 to 13, 0 to 100% aqueous, organic modifier

pH:
1 to 13

Temperature:
5°C to 85°C

Stationary Phase:
PRP-C18

Column Type:
Reversed Phase

Material:
Stainless Steel

Img

Fischer Scientific

13-622-110

--


Diameter (Metric):
4.6 mm

For Use With:
LC/MS Separation

Max. Pressure:
5000 psi (345 bar)

Particle Size:
5 μm

Pore Size:
100 Å

USP Type:
L21

Packing Material:
Polymer

Phase:
Reversed Phase

Type:
Column

Film Thickness:
5 μm

Length (Metric):
250 mm

Mobile Phase Compatibility:
pH 1 to 13, 0 to 100% aqueous, organic modifier

pH:
1 to 13

Temperature:
5°C to 85°C

Stationary Phase:
PRP-C18

Column Type:
Reversed Phase

Material:
Stainless Steel