13-684-110

Hamilton™ 1000 Series Gastight™ Syringes: Fixed-Needle Syringes, LTN Termination, 22 Gauge, 2 in. Needle Length

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 13-684-110-Each-of-1 In Stock ₹ 9,069.36

13-684-110 - Each of 1

₹ 9,069.36

In Stock

Quantity

1

Base Price: ₹ 9,069.36

GST (18%): ₹ 1,632.485

Total Price: ₹ 10,701.845

Autoclavable

Not Autoclavable

Needle Gauge

22 G

Diameter (English) Inner Needle

0.016 in.

Diameter (English) Outer Needle

0.028 in.

Diameter (Metric) Inner

7.29 mm

Diameter (Metric) Outer Needle

0.72 mm

Length (English) Needle

2 in.

Max. Pressure

200 psi

Max. Temperature (Metric)

50°C

Model

Model: 1002

Quantity

Ea.

Needle Point Style

2

Material

Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner

0.28 in.

Diameter (Metric) Inner Needle

0.41 mm

Diameter (English) Outer

0.4 in.

Diameter (Metric) Outer

10.3 mm

For Use With (Application)

Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Product Type

Gastight Syringe

Max. Temperature (English)

122°F

Min. Temperature (English)

50°F

Needle Point Number

2

Volume (Metric)

2.5 mL

Connection Type

Luer Tip, Cemented

Related Products

Img

Fischer Scientific

14-815-153

--

Img

Fischer Scientific

14-813-144

--

Img

Fischer Scientific

14-815-168

--

Img

Fischer Scientific

14-813-145

--

Img

Fischer Scientific

14-815-128

--

Img

Fischer Scientific

14-815-185

--

Img

Fischer Scientific

14-813-146

--

Img

Fischer Scientific

14-813-143

--

Description

  • 1000 Series Syringe Terminations Luer Tip Cemented Needle (LTN)- For mid volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 33-10 Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 33-10 Point Style 5 - Conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring
  • Available gauges: 26-10

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-684-110

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
0.016 in.

Diameter (English) Outer Needle:
0.028 in.

Diameter (Metric) Inner:
7.29 mm

Diameter (Metric) Outer Needle:
0.72 mm

Length (English) Needle:
2 in.

Max. Pressure:
200 psi

Max. Temperature (Metric):
50°C

Model:
Model: 1002

Quantity:
Ea.

Needle Point Style:
2

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.28 in.

Diameter (Metric) Inner Needle:
0.41 mm

Diameter (English) Outer:
0.4 in.

Diameter (Metric) Outer:
10.3 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Product Type:
Gastight Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Volume (Metric):
2.5 mL

Connection Type:
Luer Tip, Cemented

Img

Hamilton™

13-684-112A

--


Autoclavable:
Not Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
__

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
701 N

Quantity:
__

Needle Point Style:
__

Material:
__

Diameter (English) Inner:
__

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
__

Diameter (Metric) Outer:
__

For Use With (Application):
HPLC injection valves and sample pipette

Product Type:
Microsyringe Pipette

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Volume (Metric):
0.2 to 3.0 μL

Connection Type:
__

Img

Hamilton™

13-684-112B

--


Autoclavable:
__

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
__

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Quantity:
__

Needle Point Style:
__

Material:
PTFE

Diameter (English) Inner:
__

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
__

Diameter (Metric) Outer:
__

For Use With (Application):
__

Product Type:
__

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
__

Volume (Metric):
0.2 to 3 μL

Connection Type:
__

Img

Fischer Scientific

13-684-116A

--


Autoclavable:
Not Autoclavable

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
32.6 mm

Diameter (Metric) Outer Needle:
__

Length (English) Needle:
__

Max. Pressure:
100 psi

Max. Temperature (Metric):
80°C

Model:
1100

Quantity:
Ea.

Needle Point Style:
4

Material:
CTFE (Barrel Lock), PTFE (Plunger), PTFE (Tip), PTFE (Tip), PTFE-tipped (Plunger)

Diameter (English) Inner:
1.28 in.

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
1.45 in.

Diameter (Metric) Outer:
36.9 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Product Type:
Gastight Syringe

Max. Temperature (English):
176°F

Min. Temperature (English):
50°F

Needle Point Number:
No Needle Included

Volume (Metric):
100 mL

Connection Type: