14-813-10

Hamilton™ 700/1700 Series Microliter™/Gastight™ On-Column Manual Injection Syringes

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-813-10-Each-of-1 In Stock ₹ 7,614.84

14-813-10 - Each of 1

₹ 7,614.84

In Stock

Quantity

1

Base Price: ₹ 7,614.84

GST (18%): ₹ 1,370.671

Total Price: ₹ 8,985.511

Material

Stainless Steel, Borosilicate Glass, Fused Silica

Diameter (English) Inner Needle

0.003 in.

Diameter (English) Outer Needle

0.006 in.

Diameter (Metric) Inner

0.048 cm

Diameter (Metric) Outer Needle

0.017 cm

Product Type

Microliter Syringe

Max. Temperature (English)

239°F

Model

701

Length (Metric) Needle

11.43 cm

For Use With (Equipment)

On-Column GC Injectors

Diameter (English) Inner

0.019 in.

Diameter (Metric) Inner Needle

0.01 cm

Diameter (English) Outer

0.26 in.

Diameter (Metric) Outer

0.66 cm

Length (English) Needle

4.5 in.

Max. Pressure

2000 psi

Max. Temperature (Metric)

115°C

Volume (Metric)

10 μL

Needle Point Style

3

Sterility

Sterile

Related Products

Img

Fischer Scientific

14-813-11

--

Img

Fischer Scientific

4117427

Syringes are designed to work with ...

Img

Fischer Scientific

14-815-315

--

Img

Fischer Scientific

14-815-319

--

Img

Fischer Scientific

14-815-696

--

Img

Fischer Scientific

14-816-218

--

Img

Fischer Scientific

14-815-316

--

Img

Fischer Scientific

14-815-318

--

Description

  • Syringes in this category are either Microliter (700 series) or Gastight (1700 series) syringes
  • Microliter syringes have a stainless steel plunger that is hand-fitted to the glass barrel and are designed for liquid sampling
  • Gastight syringes have a precision-machined PTFE plunger tip which creates a leak-free seal
  • Removable Needle Fused Silica (RNFS)- The needles are removable and are a Hamilton-specific design
  • The design allows the needles to seat precisely at the zero graduation mark of the syringe
  • Users can select the needle gauge, length, and point style to optimize the syringe for custom applications
  • Additionally, this termination allows for a removable needle without increasing the dead volume of the syringe and is ideal when there is a risk of the needle clogging
  • Autoclavable when disassembled
  • Repeated autoclaving will shorten syringe life
  • These RN have a fused silica needle coated with polyimide
  • Needle Point Styles Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 32 Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 0.17mm and 0.23mm

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-813-10

--


Material:
Stainless Steel, Borosilicate Glass, Fused Silica

Diameter (English) Inner Needle:
0.003 in.

Diameter (English) Outer Needle:
0.006 in.

Diameter (Metric) Inner:
0.048 cm

Diameter (Metric) Outer Needle:
0.017 cm

Product Type:
Microliter Syringe

Max. Temperature (English):
239°F

Model:
701

Length (Metric) Needle:
11.43 cm

For Use With (Equipment):
On-Column GC Injectors

Diameter (English) Inner:
0.019 in.

Diameter (Metric) Inner Needle:
0.01 cm

Diameter (English) Outer:
0.26 in.

Diameter (Metric) Outer:
0.66 cm

Length (English) Needle:
4.5 in.

Max. Pressure:
2000 psi

Max. Temperature (Metric):
115°C

Volume (Metric):
10 μL

Needle Point Style:
3

Sterility:
Sterile

Img

Fischer Scientific

14-813-100

--


Material:
__

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
0.1 mm

Diameter (Metric) Outer Needle:
0.515 mm

Product Type:
General Purpose Syringe

Max. Temperature (English):
239°F

Model:
__

Length (Metric) Needle:
__

For Use With (Equipment):
HPLC Injection Valves

Diameter (English) Inner:
0.004 in.

Diameter (Metric) Inner Needle:
0.104 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.82 mm

Length (English) Needle:
2.75 in.

Max. Pressure:
6000 psi

Max. Temperature (Metric):
115°C

Volume (Metric):
0.5 μL

Needle Point Style:
Blunt

Sterility:
__

Img

Fischer Scientific

14-813-101

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
0.0762 mm

Diameter (Metric) Outer Needle:
0.508 mm

Product Type:
Microliter Syringe

Max. Temperature (English):
239°F

Model:
7000.5 KHCH SYR

Length (Metric) Needle:
__

For Use With (Equipment):
__

Diameter (English) Inner:
0.003 in.

Diameter (Metric) Inner Needle:
0.1 mm

Diameter (English) Outer:
0.308 in.

Diameter (Metric) Outer:
7.82 mm

Length (English) Needle:
2.75 in.

Max. Pressure:
6000 psi

Max. Temperature (Metric):
115°C

Volume (Metric):
0.5 μL

Needle Point Style:
Blunt

Sterility:
__

Img

Fischer Scientific

14-813-102

--


Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner Needle:
0.004 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
0.07 mm

Diameter (Metric) Outer Needle:
0.5 mm

Product Type:
MicroliterGeneral Purpose Syringe

Max. Temperature (English):
239°F

Model:
7000.5

Length (Metric) Needle:
__

For Use With (Equipment):
__

Diameter (English) Inner:
0.003 in.

Diameter (Metric) Inner Needle:
0.1 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.82 mm

Length (English) Needle:
2.75 in.

Max. Pressure:
6000 psi

Max. Temperature (Metric):
115°C

Volume (Metric):
0.5 μL

Needle Point Style:
Blunt

Sterility:
__