14-813-224

Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: KH Termination

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-813-224-Each-of-1 In Stock ₹ 40,469.88

14-813-224 - Each of 1

₹ 40,469.88

In Stock

Quantity

1

Base Price: ₹ 40,469.88

GST (18%): ₹ 7,284.578

Total Price: ₹ 47,754.458

Autoclavable

Autoclavable

Needle Gauge

24 G

Diameter (English) Inner Needle

0.0122 in.

Diameter (English) Outer Needle

0.0224 in.

Diameter (Metric) Inner

0.279 mm

Diameter (Metric) Outer Needle

0.57 mm

Includes

Built-in chaney adapter, small plunger wires

Length (English) Needle

2.75 in.

Product Type

Microliter Syringe

Max. Temperature (English)

239°F

Min. Temperature (English)

50°F

Needle Point Number

3

Quantity

Ea.

Needle Point Style

Blunt

Material

Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner

0.011 in.

Diameter (Metric) Inner Needle

0.31 mm

Diameter (English) Outer

0.308 in.

Diameter (Metric) Outer

7.82 mm

For Use With (Application)

Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting

Length (English)

2.75 in.

Length (Metric)

70 mm

Max. Pressure

6000 psi

Max. Temperature (Metric)

115°C

Model

7105 KHCH SYR

Min. Temperature (Metric)

10°C

Volume (Metric)

5 μL

Connection Type

Knurled Hub

Related Products

Img

Fischer Scientific

14-813-101

--

Img

Fischer Scientific

14-824-27A

--

Img

Fischer Scientific

14-813-225

--

Img

Fischer Scientific

14-813-213

--

Img

Fischer Scientific

14-813-201

--

Img

Fischer Scientific

14-813-102

--

Img

Fischer Scientific

14-813-113

--

Img

Fischer Scientific

14-813-214

--

Description

  • Built to adjust reproducible injections and to prevent the plunger from bending
  • Syringes in this category are either Microliter (700/7000 series) or Gastight (1700/1000 series) syringes
  • Microliter syringes have a stainless steel plunger that is hand-fitted to the glass barrel and are designed for liquid sampling
  • Gastight syringes have a PTFE plunger tip that creates tight connection between the syringe barrel and plunger allowing for liquid or gas sampling
  • These syringes have Knurled Hub (KH) termination
  • Available in 0.5μL to 10mL in volume
  • Knurled Hub (KH)- Removable plunger/needle assembly, knurled hub is used exclusively on the 7000 series syringes
  • Needle Point Styles Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 26s, 25, 24, 23, 22, 22s Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 26s, 25, 24, 23, 22, 22s

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-813-224

--


Autoclavable:
Autoclavable

Needle Gauge:
24 G

Diameter (English) Inner Needle:
0.0122 in.

Diameter (English) Outer Needle:
0.0224 in.

Diameter (Metric) Inner:
0.279 mm

Diameter (Metric) Outer Needle:
0.57 mm

Includes:
Built-in chaney adapter, small plunger wires

Length (English) Needle:
2.75 in.

Product Type:
Microliter Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
3

Quantity:
Ea.

Needle Point Style:
Blunt

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.011 in.

Diameter (Metric) Inner Needle:
0.31 mm

Diameter (English) Outer:
0.308 in.

Diameter (Metric) Outer:
7.82 mm

For Use With (Application):
Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting

Length (English):
2.75 in.

Length (Metric):
70 mm

Max. Pressure:
6000 psi

Max. Temperature (Metric):
115°C

Model:
7105 KHCH SYR

Min. Temperature (Metric):
10°C

Volume (Metric):
5 μL

Connection Type:
Knurled Hub

Img

Fischer Scientific

14-813-225

--


Autoclavable:
Autoclavable

Needle Gauge:
24 G

Diameter (English) Inner Needle:
0.01 in.

Diameter (English) Outer Needle:
0.02 in.

Diameter (Metric) Inner:
0.27 mm

Diameter (Metric) Outer Needle:
0.57 mm

Includes:
Built-in syringe guide, small plunger wires

Length (English) Needle:
2.75 in.

Product Type:
MicroliterGeneral Purpose Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
3

Quantity:
Ea.

Needle Point Style:
Blunt

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.01 in.

Diameter (Metric) Inner Needle:
0.31 mm

Diameter (English) Outer:
0.3 in.

Diameter (Metric) Outer:
7.82 mm

For Use With (Application):
Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting

Length (English):
2.75 in.

Length (Metric):
70 mm

Max. Pressure:
6000 psi

Max. Temperature (Metric):
115°C

Model:
7105

Min. Temperature (Metric):
10°C

Volume (Metric):
5 μL

Connection Type:
Knurled Hub

Img

Fischer Scientific

14-813-24

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22s G

Diameter (English) Inner Needle:
0.0059 in.

Diameter (English) Outer Needle:
0.0283 in.

Diameter (Metric) Inner:
0.729 mm

Diameter (Metric) Outer Needle:
0.72 mm

Includes:
__

Length (English) Needle:
2 in.

Product Type:
Microliter Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
5

Quantity:
Ea.

Needle Point Style:
Cone

Material:
Stainless Steel (Plunger)

Diameter (English) Inner:
0.029 in.

Diameter (Metric) Inner Needle:
0.15 mm

Diameter (English) Outer:
0.305 in.

Diameter (Metric) Outer:
7.75 mm

For Use With (Application):
For dispensing low volumes to achieve the highest level of accuracy and precision possible

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
2000 psi

Max. Temperature (Metric):
50°C

Model:
702

Min. Temperature (Metric):
__

Volume (Metric):
25 μL

Connection Type:
Cemented

Img

Fischer Scientific

14-813-256

--


Autoclavable:
__

Needle Gauge:
23 to 26s G

Diameter (English) Inner Needle:
0.0133 to 0.005 in.

Diameter (English) Outer Needle:
0.0283 to 0.0187 in.

Diameter (Metric) Inner:
0.343 mm

Diameter (Metric) Outer Needle:
0.72 to 0.47 mm

Includes:
__

Length (English) Needle:
1.71 in.

Product Type:
Microliter Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
AS

Quantity:
Ea.

Needle Point Style:
Cone

Material:
Borosilicate Glass (Barrel), Stainless Steel (Plunger)

Diameter (English) Inner:
0.014 in.

Diameter (Metric) Inner Needle:
0.64 to 0.13 mm

Diameter (English) Outer:
0.26 in.

Diameter (Metric) Outer:
6.6 mm

For Use With (Application):
__

Length (English):
1.7 in.

Length (Metric):
43 mm

Max. Pressure:
2000 psi

Max. Temperature (Metric):
50°C

Model:
75 N (Cemented Needle)

Min. Temperature (Metric):
10°C

Volume (Metric):
5 μL

Connection Type:
Cemented