14-815-150

Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: N Termination

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 14-815-150-Each-of-1 In Stock ₹ 26,780.28

14-815-150 - Each of 1

₹ 26,780.28

In Stock

Quantity

1

Base Price: ₹ 26,780.28

GST (18%): ₹ 4,820.45

Total Price: ₹ 31,600.73

Autoclavable

Not Autoclavable

Needle Gauge

22 G

Diameter (English) Inner Needle

0.0161 in.

Diameter (English) Outer Needle

0.0283 in.

Diameter (Metric) Inner

7.29 mm

Diameter (Metric) Outer Needle

0.72 mm

Includes

Built-in chaney adapter, small plunger wires

Length (English) Needle

2 in.

Product Type

Gastight Syringe

Max. Temperature (English)

122°F

Min. Temperature (English)

50°F

Needle Point Number

2

Quantity

Ea.

Length (Metric) Needle

51 mm

Connection Type

Luer Tip, Cemented

Material

Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner

0.287 in.

Diameter (Metric) Inner Needle

0.41 mm

Diameter (English) Outer

0.407 in.

Diameter (Metric) Outer

10.3 mm

For Use With (Application)

Designed for liquid sampling to achieve the highest level of accuracy and precision possible, recommended for septum penetration

Length (English)

2 in.

Length (Metric)

51 mm

Max. Pressure

200 psi

Max. Temperature (Metric)

50°C

Model

1002 LTNCH SYR

Min. Temperature (Metric)

10°C

Volume (Metric)

2.5 mL

Needle Point Style

Sharp, Bevel, Curved, Non-coring

Related Products

Img

Fischer Scientific

14-815-165

--

Img

Fischer Scientific

14-815-5

--

Img

Fischer Scientific

14-824-4A

--

Img

Fischer Scientific

14-815-125

--

Img

Hamilton™

14-813-4

--

Img

Hamilton™

14-824-8

--

Img

Fischer Scientific

14-815-226

--

Img

Fischer Scientific

14-815-204

--

Description

  • Built to adjust reproducible injections and to prevent the plunger from bending
  • Syringes in this category are either Microliter (700/7000 series) or Gastight (1700/1000 series) syringes
  • Microliter syringes have a stainless steel plunger that is hand-fitted to the glass barrel and are designed for liquid sampling
  • Gastight syringes have a PTFE plunger tip that creates tight connection between the syringe barrel and plunger allowing for liquid or gas sampling
  • These syringes have cemented needle (N) termination
  • Available in 0.5μL to 10mL in volume
  • Cemented Needle (N)- For low volume syringes the needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark
  • With this termination, dead volume is limited to the internal volume of the needle
  • Not autoclavable
  • Needle gauge is determined by the syringe volume and are not user-selectable
  • Needle Point Styles Point Style 2 - Sharp, beveled, curved, non-coring needle point recommended for septum penetration
  • Available gauges: 26s, 25, 24, 23, 22, 22s Point Style 3 - Blunt needle point for use with HPLC injection valves and for sample pipetting
  • Available gauges: 26s, 25, 24, 23, 22, 22s

Compare Similar Items

Show Difference

Img

Fischer Scientific

14-815-150

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
0.0161 in.

Diameter (English) Outer Needle:
0.0283 in.

Diameter (Metric) Inner:
7.29 mm

Diameter (Metric) Outer Needle:
0.72 mm

Includes:
Built-in chaney adapter, small plunger wires

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Length (Metric) Needle:
51 mm

Connection Type:
Luer Tip, Cemented

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.287 in.

Diameter (Metric) Inner Needle:
0.41 mm

Diameter (English) Outer:
0.407 in.

Diameter (Metric) Outer:
10.3 mm

For Use With (Application):
Designed for liquid sampling to achieve the highest level of accuracy and precision possible, recommended for septum penetration

Length (English):
2 in.

Length (Metric):
51 mm

Max. Pressure:
200 psi

Max. Temperature (Metric):
50°C

Model:
1002 LTNCH SYR

Min. Temperature (Metric):
10°C

Volume (Metric):
2.5 mL

Needle Point Style:
Sharp, Bevel, Curved, Non-coring

Img

Fischer Scientific

14-815-151

--


Autoclavable:
__

Needle Gauge:
__

Diameter (English) Inner Needle:
__

Diameter (English) Outer Needle:
__

Diameter (Metric) Inner:
__

Diameter (Metric) Outer Needle:
__

Includes:
__

Length (English) Needle:
__

Product Type:
__

Max. Temperature (English):
__

Min. Temperature (English):
__

Needle Point Number:
No Needle Included

Quantity:
__

Length (Metric) Needle:
__

Connection Type:
__

Material:
__

Diameter (English) Inner:
__

Diameter (Metric) Inner Needle:
__

Diameter (English) Outer:
__

Diameter (Metric) Outer:
__

For Use With (Application):
__

Length (English):
__

Length (Metric):
__

Max. Pressure:
__

Max. Temperature (Metric):
__

Model:
__

Min. Temperature (Metric):
__

Volume (Metric):
2.5 mL

Needle Point Style:
__

Img

Fischer Scientific

14-815-152

--


Autoclavable:
Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
0.016 in.

Diameter (English) Outer Needle:
0.028 in.

Diameter (Metric) Inner:
7.29 mm

Diameter (Metric) Outer Needle:
0.72 mm

Includes:
__

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
239°F

Min. Temperature (English):
50°F

Needle Point Number:
2

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Removable

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.28 in.

Diameter (Metric) Inner Needle:
0.41 mm

Diameter (English) Outer:
0.4 in.

Diameter (Metric) Outer:
10.3 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Length (English):
__

Length (Metric):
__

Max. Pressure:
200 psi

Max. Temperature (Metric):
115°C

Model:
1002

Min. Temperature (Metric):
__

Volume (Metric):
2.5 mL

Needle Point Style:
Sharp, Bevel, Curved, Non-coring

Img

Fischer Scientific

14-815-153

--


Autoclavable:
Not Autoclavable

Needle Gauge:
22 G

Diameter (English) Inner Needle:
0.016 in.

Diameter (English) Outer Needle:
0.028 in.

Diameter (Metric) Inner:
7.29 mm

Diameter (Metric) Outer Needle:
0.72 mm

Includes:
__

Length (English) Needle:
2 in.

Product Type:
Gastight Syringe

Max. Temperature (English):
122°F

Min. Temperature (English):
50°F

Needle Point Number:
5

Quantity:
Ea.

Length (Metric) Needle:
__

Connection Type:
Luer Tip, Cemented

Material:
Borosilicate Glass (Barrel), PTFE (Tip), Stainless Steel (Plunger)

Diameter (English) Inner:
0.28 in.

Diameter (Metric) Inner Needle:
0.41 mm

Diameter (English) Outer:
0.4 in.

Diameter (Metric) Outer:
10.3 mm

For Use With (Application):
Ideal for manual and automated HPLC injections, commonly used in syringe pumps and other liquid handling instruments

Length (English):
__

Length (Metric):
__

Max. Pressure:
200 psi

Max. Temperature (Metric):
50°C

Model:
Model 1002

Min. Temperature (Metric):
__

Volume (Metric):
2.5 mL

Needle Point Style:
Cone