21-279-174

Siemens Healthcare Diagnostics ADVIA Centaur TSH3-Ultra II

Manufacturer: Siemens Healthcare Diagnostics

Select a Size

Pack Size SKU Availability Price
Pack of 500 21-279-174-Pack-of-500 In Stock ₹ 2,15,012.28

21-279-174 - Pack of 500

₹ 2,15,012.28

In Stock

Quantity

1

Base Price: ₹ 2,15,012.28

GST (18%): ₹ 38,702.21

Total Price: ₹ 2,53,714.49

Content And Storage

5 ReadyPack primary reagent packs containing:• TSH3ULII Lite Reagent, solid phase• Ancillary Well Reagent• CAL3A H/L, 2 vialsStore at 2°C to 8°C.

Clia Complexity

Moderate Complexity

Detection Method

Chemiluminescence

Sample Type

Serum, EDTA plasma, Heparinized plasma

Disposable

Single-use

For Use With (Equipment)

ADVIA Centaur XP/XPT

Quantity

100 Tests

Form

Liquid Ready-to-Use

CE Marker

Yes

Detectable Analytes

Thyroid Stimulating Hormone (TSH)

DoA Calibrators

Yes

Type

Assay

Formulation

BSA, BGG, goat serum, sodium azide (<0.1%), surfactant, preservatives

Linearity

Assay is linear for the measuring interval of 0.010 to 150.000 μL U/mL (mL U/L). Linearity testing was performed in accordance with CLSI Document EP06-ed2.22.

Analysis Time

18 Minutes

Related Products

Img

ZeptoMetrix

22-158-304

--

Img

ZeptoMetrix

22-158-306

--

Img

ZeptoMetrix

22-158-308

--

Img

ZeptoMetrix

22-158-315

--

Img

ZeptoMetrix

22-158-321

--

Img

ZeptoMetrix

22-158-310

--

Img

ZeptoMetrix

22-158-311

--

Img

ZeptoMetrix

22-158-312

--

Description

  • An assay for in vitro diagnostic use in the quantitative determination of thyroid-stimulating hormone (TSH, thyrotropin) in human serum and plasma.

Compare Similar Items

Show Difference

Img

Siemens Healthcare Diagnostics

21-279-174

--


Content And Storage:
5 ReadyPack primary reagent packs containing:• TSH3ULII Lite Reagent, solid phase• Ancillary Well Reagent• CAL3A H/L, 2 vialsStore at 2°C to 8°C.

Clia Complexity:
Moderate Complexity

Detection Method:
Chemiluminescence

Sample Type:
Serum, EDTA plasma, Heparinized plasma

Disposable:
Single-use

For Use With (Equipment):
ADVIA Centaur XP/XPT

Quantity:
100 Tests

Form:
Liquid Ready-to-Use

CE Marker:
Yes

Detectable Analytes:
Thyroid Stimulating Hormone (TSH)

DoA Calibrators:
Yes

Type:
Assay

Formulation:
BSA, BGG, goat serum, sodium azide (<0.1%), surfactant, preservatives

Linearity:
Assay is linear for the measuring interval of 0.010 to 150.000 μL U/mL (mL U/L). Linearity testing was performed in accordance with CLSI Document EP06-ed2.22.

Analysis Time:
18 Minutes

Img

Fischer Scientific

21-279-186

--


Content And Storage:
__

Clia Complexity:
__

Detection Method:
__

Sample Type:
__

Disposable:
__

For Use With (Equipment):
G7 Automated HPLC Analyzer

Quantity:
2000 mL

Form:
__

CE Marker:
__

Detectable Analytes:
__

DoA Calibrators:
__

Type:
Hemolysis and Wash Solution

Formulation:
__

Linearity:
__

Analysis Time:
__

Img

Fischer Scientific

21-279-21

--


Content And Storage:
__

Clia Complexity:
__

Detection Method:
__

Sample Type:
__

Disposable:
__

For Use With (Equipment):
__

Quantity:
5 trays of 20 cups

Form:
__

CE Marker:
__

Detectable Analytes:
__

DoA Calibrators:
__

Type:
TSH 3G Test Cup

Formulation:
__

Linearity:
__

Analysis Time:
__

Img

Tosoh Bioscience

21-279-214

--


Content And Storage:
__

Clia Complexity:
__

Detection Method:
__

Sample Type:
__

Disposable:
__

For Use With (Equipment):
__

Quantity:
5 trays of 20 cups

Form:
__

CE Marker:
__

Detectable Analytes:
__

DoA Calibrators:
__

Type:
1st TSH Assay Cups

Formulation:
__

Linearity:
__

Analysis Time:
__