50-112-1287

Molecular Probes™ Fetal Hemoglobin Test Kit, FITC

Manufacturer: Molecular Probes™

Select a Size

Pack Size SKU Availability Price
Each of 1 50-112-1287-Each-of-1 In Stock ₹ 58,009.68

50-112-1287 - Each of 1

₹ 58,009.68

In Stock

Quantity

1

Base Price: ₹ 58,009.68

GST (18%): ₹ 10,441.742

Total Price: ₹ 68,451.422

Antibody Conjugate

Classic Dyes (e.g. FITC, TRITC), FITC (Fluorescein)

CE Marker

Yes

Format

Kit

For Use With (Application)

Flow Cytometry Antibodies and Secondary Detection

Quantity

100 Tests

Species

Mouse

Content And Storage

Store in refrigerator (2°C to 8°C).

Detection Method

Fluorescence

Type

Hemoglobin Test Kit

Label or Dye

FITC (Fluorescein)

Shipping Condition

Wet Ice

Related Products

Img

Molecular Probes™

50-113-7426

--

Img

Fischer Scientific

109331

Cell Preservative is an easy-to-use...

Img

Fischer Scientific

23-045-412

--

Img

Fischer Scientific

23-046-501D

--

Img

Fischer Scientific

23-046-501G

--

Img

Fischer Scientific

22-024-769

--

Img

Meridian Bioscience™

23-043-155

--

Img

Fischer Scientific

108072

VQC peer review program allows user...

Description

  • The Fetal Hemoglobin (HbF) Test is based on a monoclonal antibody directed to fetal hemoglobin (hemoglobin F)
  • This antibody is conjugated with fluorescein (FITC)
  • Commonly used, the fluorescein conjugates provide relatively high absorptivity, excellent fluorescence quantum yield, and good water solubility
  • This reagent is intended for the identification followed by enumeration of fetal red blood cells
  • Fetal cells are identified by the presence of fetal hemoglobin using a flow cytometric method
  • The Fetal Hemoglobin Test may be used as an aid in identifying fetal-maternal hemorrhage and determining the need for immunoprophylaxis with immune globulin
  • Antibody Specifications Description: Fetal Hemoglobin F (HbF), mouse IgG1 monoclonal Label: Fluorescein (FITC) Validated Application: Flow Cytometry Species Reactivity: Human Ex/Em and laser configuration: 488/519 nm, blue laser Clone ID: HbF-1 Clinical Relevance The Fetal Hemoglobin Test contains a monoclonal antibody directed to HbF that specifically recognizes fetal hemoglobin found in fetal erythrocytes
  • The test permits the enumeration of fetal erythrocytes in the maternal circulation as a result of a fetal-maternal hemorrhage, or leakage, of fetal cells into the maternal circulation
  • Hemorrhage of cells from an Rh+ fetus into the circulation of an Rh- mother may result in the formation of Rh-reactive antibodies in the mother
  • Rh hemolytic anemia in a subsequent Rh+ fetus may result from placental transfer of antibodies formed in the mother to the fetus
  • Although the volume of fetal erythrocytes found in the maternal circulation during pregnancy and immediately post-partum is reported to be small and of uncertain clinical significance in many cases, substantial hemorrhage may result from a number of causes including fetal or maternal trauma and placental defects
  • Erythrocytes containing fetal hemoglobin may be found in individuals of any age, but with lower amounts of fetal hemoglobin compared to fetal red cells
  • These cells have been termed F cells
  • High levels of F cells may also exist in adults with a heterogeneous group of genetic disorders of uncertain etiology, referred to as Hereditary Persistence of Fetal Hemoglobin
  • Other clinical conditions causing significant levels of anemia may also result in elevated levels of F cells
  • Several clinical conditions have been described with increased levels of F cells
  • These conditions include hereditary anemic diseases such as sickle cell anemia and thalassemia major
  • Additional Information Use the Spectraviewer to help you plan your experiments
  • Additional general information about Life Technologies flow cytometry products and support is also available.

Compare Similar Items

Show Difference

Img

Molecular Probes™

50-112-1287

--


Antibody Conjugate:
Classic Dyes (e.g. FITC, TRITC), FITC (Fluorescein)

CE Marker:
Yes

Format:
Kit

For Use With (Application):
Flow Cytometry Antibodies and Secondary Detection

Quantity:
100 Tests

Species:
Mouse

Content And Storage:
Store in refrigerator (2°C to 8°C).

Detection Method:
Fluorescence

Type:
Hemoglobin Test Kit

Label or Dye:
FITC (Fluorescein)

Shipping Condition:
Wet Ice

Img

Invitrogen

50-112-13

--


Antibody Conjugate:
__

CE Marker:
__

Format:
__

For Use With (Application):
__

Quantity:
25 Tests

Species:
__

Content And Storage:
4° C, store in dark, DO NOT FREEZE!

Detection Method:
__

Type:
__

Label or Dye:
__

Shipping Condition:
__

Img

Invitrogen

50-112-1380

--


Antibody Conjugate:
__

CE Marker:
__

Format:
__

For Use With (Application):
__

Quantity:
500 μL

Species:
__

Content And Storage:
4° C, store in dark

Detection Method:
__

Type:
__

Label or Dye:
__

Shipping Condition:
__

Img

Invitrogen

50-112-1392

--


Antibody Conjugate:
__

CE Marker:
__

Format:
__

For Use With (Application):
__

Quantity:
500 μL

Species:
__

Content And Storage:
4° C, store in dark

Detection Method:
__

Type:
__

Label or Dye:
__

Shipping Condition:
__