4187745

Sartorius Vivacon™ 500 DNA Concentrator

For up to 500 μL, Vivacon™ 500 are centrifugal units for fast DNA concentration and buffer exchange of 500 μL samples. They are also the product of choice for protein fractionation applications. The use of Hydrosart™ membranes results in high recoveries from dilute samples.

Manufacturer: Fischer Scientific

The price for this product is unavailable. Please request a quote

Concentration

50ng/mL

Material (Membrane)

Hydrosart Regenerated Cellulose

For Use With (Application)

DNA concentration, desalting, buffer exchange, fractionation

Type

Vivacon 500 Concentrator

Volume (Metric) Hold Up

<5 μL

Length (English)

1.77 in.

Length (Metric)

4.5 cm

Width (English)

0.48 in.

Material

Polycarbonate Body, Polypropylene Filtrate Vessel

Filtration Area

0.32 cm2

Sample Type

DNA, peptide

Volume (Metric)

0.5 mL

Dimensions (L x W)

1.77 x 0.48 in. (4.5 x 1.24cm)

Length (English) Back Spin

1.87 in.

Length (Metric) Back Spin

4.75 cm

Width (Metric)

1.24 cm

Related Products

Img

Fischer Scientific

4187744

Centrifugal units for fast DNA conc...

Img

Fischer Scientific

4187748

Single use. Sartorius Vivaflow™ 50 ...

Img

Sartorius

14-558-311

--

Img

Fischer Scientific

117433

Small-volume tangential flow filter...

Img

Fischer Scientific

PXC300C50

--

Img

Fischer Scientific

PXC005C50

--

Img

Fischer Scientific

PXC010C50

--

Img

Fischer Scientific

PXC030C50

--

Description

  • For up to 500 μL, Vivacon™ 500 are centrifugal units for fast DNA concentration and buffer exchange of 500 μL samples
  • They are also the product of choice for protein fractionation applications
  • The use of Hydrosart™ membranes results in high recoveries from dilute samples
  • Vivacon 500 are centrifugal devices for DNA concentration and buffer exchange applications for samples up to 500μl
  • They are also the product of choice for protein fractionation applications in this volume range
  • For optimal performance with very diluted samples, e.g
  • forensic specimens, Vivacon 500 is equipped with patented Hydrosart™ regenerated cellulose membranes with extremely low unspecific binding properties and high flux
  • High recoveries and excellent reproducibility are paired with convenience offered by volume graduation and molecular weight cut-offs printed on individual devices
  • Vivacon 500 features a horizontal membrane design optimal for DNA fractionation (primer removal) as well as protein fractionation (peptide removal)
  • The possibility of a reverse spin after sample processing assures complete concentrate recovery which is especially important when working with low sample concentrations
  • Convenient handling in fixed-angle rotors Low binding material Reverse spin possibility MWCO printed on Complete and highly reproducible concentrate recovery

Compare Similar Items

Show Difference

Img

Fischer Scientific

4187745

For up to 500 μL, Vivacon™ 500 are ...


Concentration:
50ng/mL

Material (Membrane):
Hydrosart Regenerated Cellulose

For Use With (Application):
DNA concentration, desalting, buffer exchange, fractionation

Type:
Vivacon 500 Concentrator

Volume (Metric) Hold Up:
<5 μL

Length (English):
1.77 in.

Length (Metric):
4.5 cm

Width (English):
0.48 in.

Material:
Polycarbonate Body, Polypropylene Filtrate Vessel

Filtration Area:
0.32 cm2

Sample Type:
DNA, peptide

Volume (Metric):
0.5 mL

Dimensions (L x W):
1.77 x 0.48 in. (4.5 x 1.24cm)

Length (English) Back Spin:
1.87 in.

Length (Metric) Back Spin:
4.75 cm

Width (Metric):
1.24 cm

Img

Fischer Scientific

4187746

Offers a standard for ease of use, ...


Concentration:
__

Material (Membrane):
__

For Use With (Application):
Cell culture supernatant concentration, virus concentration and water concentration

Type:
Crossflow Cassette

Volume (Metric) Hold Up:
5.3 mL

Length (English):
__

Length (Metric):
12.6 cm

Width (English):
__

Material:
Acrylic

Filtration Area:
200 cm2

Sample Type:
__

Volume (Metric):
500 mL to 5 L

Dimensions (L x W):
__

Length (English) Back Spin:
__

Length (Metric) Back Spin:
__

Width (Metric):
3.8 cm

Img

Fischer Scientific

4187748

Single use. Sartorius Vivaflow™ 50 ...


Concentration:
__

Material (Membrane):
__

For Use With (Application):
Cell culture supernatant concentration, virus concentration and water concentration

Type:
Crossflow Cassette

Volume (Metric) Hold Up:
__

Length (English):
4.21 in.

Length (Metric):
10.7 cm

Width (English):
0.98 in.

Material:
Polycarbonate

Filtration Area:
50 cm2

Sample Type:
__

Volume (Metric):
10 mL to 1 L

Dimensions (L x W):
__

Length (English) Back Spin:
__

Length (Metric) Back Spin:
__

Width (Metric):
2.5 cm

Img

Fischer Scientific

4187749

Ideal for general purpose laborator...


Concentration:
__

Material (Membrane):
PES

For Use With (Application):
__

Type:
__

Volume (Metric) Hold Up:
__

Length (English):
__

Length (Metric):
__

Width (English):
__

Material:
__

Filtration Area:
28 cm2

Sample Type:
__

Volume (Metric):
2 to 10 mL, 20 mL

Dimensions (L x W):
__

Length (English) Back Spin:
__

Length (Metric) Back Spin:
__

Width (Metric):
__