PIA43882

Thermo Scientific™ Pierce™ Rapid Gel Clot Endotoxin Assay Kits

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 PIA43882-Each-of-1 In Stock ₹ 81,709.80

PIA43882 - Each of 1

₹ 81,709.80

In Stock

Quantity

1

Base Price: ₹ 81,709.80

GST (18%): ₹ 14,707.764

Total Price: ₹ 96,417.564

Content And Storage

• Positive Control Tubes• Endotoxin-Free Sample Reaction Tubes• Endotoxin-Free Pipette Tips• Endotoxin-Free Sample BottlesStore Sample and Positive Control Reaction Tubes at 4°C.Store pipette tips and sample bottles at room temperature.

Format

Kit

For Use With (Application)

This kit is not licensed by the FDA and is not to be used for the end-product release of pharmaceutical drugs, devices, or biologics that are FDA regulated. For Research Use Only.

Quantity

10 Assays

Description

Pierce™ Rapid Gel Clot Endotoxin Assay Kit, 0.50 EU/mL

Product Type

End-Point Gel Clot LAL Assay

Product Line

Pierce™

Sensitivity

0.5 EU/mL

Related Products

Img

Fischer Scientific

PIA43881

--

Img

Fischer Scientific

PIA43880

--

Img

Fischer Scientific

PIA43879

--

Img

Fischer Scientific

200007179

Rapid Gel Clot Endotoxin Assay Kits...

Img

FUJIFILM Wako

12-333-043

--

Img

FUJIFILM Wako

12-333-052

--

Img

FUJIFILM Wako

12-333-053

--

Img

FUJIFILM Wako

12-333-034

--

Description

  • Endotoxin is a lipopolysaccharide (LPS) that constitutes much of the outer membrane of the cell wall in gram-negative bacteria
  • LPS is the most abundant antigen on the cell surface of most gram-negative bacteria
  • Thermo Fisher Scientific Pierce Rapid Gel Clot Endotoxin Assay kits provide rapid and easy-to-read qualitative results indicating the presence or absence of endotoxins
  • They are best suited for samples that are viscous or highly colored and are available in a variety of sensitivities: 0.03, 0.125, 0.25, and 0.5 EU/mL
  • These Rapid Gel Clot Endotoxin Assay kits have a fast, efficient protocol, are reproducible and contain all the reagents and supplies such as positive control tubes, endotoxin-free tubes, and pipette tips required for each test
  • Each kit is sufficient for 10 tests, using 0.5 mL of test sample
  • Pierce Rapid Gel Clot Endotoxin Assay kits use amebocyte lysates derived from the Limulus horseshoe crab hemolymph to detect endotoxin levels in samples
  • Limulus amebocyte lysate (LAL) is widely used as a simple and sensitive assay for detection of endotoxins
  • When endotoxin encounters the amebocyte lysate, a series of enzymatic reactions form a gel-like clot
  • In a positive test, a clot will form in the sample tube, indicating that the amount of endotoxin in the sample is greater than or equal to the listed sensitivity (in EU/mL) of the kit
  • A lack of gel clot formation in the tube is considered a negative result, indicative of an endotoxin concentration in the test tube below the kit’s sensitivity
  • Endotoxins are released in their surrounding environment when gram-negative bacteria undergo normal cell division or in large concentrations when they are damaged or undergo cell lysis
  • Given endotoxins are pyrogenic (induce fever) in mammals, identifying and monitoring endotoxin levels is extremely important in many fields
  • Endotoxin testing of raw materials, intermediates, and final drug products is essential for patient safety
  • Each kit lot has a defined assay incubation time that is listed in the Certificate of Analysis accompanying each kit
  • This kit is not licensed by the FDA and is not to be used for the end-product release of pharmaceutical drugs, devices, or biologics that are FDA regulated.

Compare Similar Items

Show Difference

Img

Fischer Scientific

PIA43882

--


Content And Storage:
• Positive Control Tubes• Endotoxin-Free Sample Reaction Tubes• Endotoxin-Free Pipette Tips• Endotoxin-Free Sample BottlesStore Sample and Positive Control Reaction Tubes at 4°C.Store pipette tips and sample bottles at room temperature.

Format:
Kit

For Use With (Application):
This kit is not licensed by the FDA and is not to be used for the end-product release of pharmaceutical drugs, devices, or biologics that are FDA regulated. For Research Use Only.

Quantity:
10 Assays

Description:
Pierce™ Rapid Gel Clot Endotoxin Assay Kit, 0.50 EU/mL

Product Type:
End-Point Gel Clot LAL Assay

Product Line:
Pierce™

Sensitivity:
0.5 EU/mL

Img

Thermo Scientific™

PIA43883

--


Content And Storage:
__

Format:
__

For Use With (Application):
__

Quantity:
4 x 50 mL

Description:
Endotoxin-Free Water

Product Type:
__

Product Line:
__

Sensitivity:
__

Img

Thermo Scientific™

PIA43885

--


Content And Storage:
__

Format:
__

For Use With (Application):
For adjusting the pH of the LAL endotoxin test samples

Quantity:
5 x 10 mL

Description:
Endotoxin-Free Tris Buffer

Product Type:
__

Product Line:
__

Sensitivity:
__

Img

Thermo Scientific™

PIA43888

--


Content And Storage:
__

Format:
Strip Plate

For Use With (Application):
Chromogenic LAL Endotoxin Assay, Kinetic Chromogenic LAL Assay and Kinetic Turbidimetric LAL Assay

Quantity:
5 plates, 1 frame

Description:
Endotoxin level <0.0005 EU/well. 12 strip x 8 well 96-well plate, strips are individual wrapped.

Product Type:
__

Product Line:
__

Sensitivity:
__