12-563-709

Invitrogen™ Olympus™ 40X Objective, fluorite, 0.60NA/2.7–4.0WD, correction collar (0–2.0 mm)

Manufacturer: Invitrogen™

Select a Size

Pack Size SKU Availability Price
Each of 1 12-563-709-Each-of-1 In Stock ₹ 2,54,541.00

12-563-709 - Each of 1

₹ 2,54,541.00

In Stock

Quantity

1

Base Price: ₹ 2,54,541.00

GST (18%): ₹ 45,817.38

Total Price: ₹ 3,00,358.38

Type

Objective Lens

For Use With (Equipment)

EVOS™

Lens Type

Fluorite with correction collar

Quantity

1 each

Product Line

Olympus

Includes

Vessels, Slides, Cell Culture Dishes, Flasks, Microtiter Well Plates

Magnification Power

40X

Shipping Condition

Room Temperature

Related Products

Img

Invitrogen™

12-563-689

--

Img

Bioptechs Inc

S96359

--

Img

Laxco™

SLI3PPROMO

--

Img

Fischer Scientific

8427009

Laxco™ Wavelength specific LED modu...

Img

Fischer Scientific

S11096A

--

Img

Invitrogen™

12-563-663

--

Img

Fischer Scientific

S11095A

--

Img

Fischer Scientific

03-000-092

--

Description

  • This fluorite (semi-apochromat) objective is equipped with an adjustable collar that affords flexibility in imaging through vessels with a thickness from 0 (no coverslip) to 1.6 mm
  • With four-color correction for spherical and chromatic aberrations, it delivers exceptional image quality
  • For the sharpest image simply set the collar to the thickness of the vessel/coverslip you are using
  • If the thickness is unknown, turn the collar in either direction while monitoring the sample focus
  • All Olympus objectives are compatible with EVOS cell imaging systems and offer outstanding optical performance from visible to near-infrared light
  • The extensive selection of EVOS and Olympus objectives satisfies needs across the spectrum of magnifications and optical specifications
  • Additional characteristics of this Olympus objective: Magnification: 40X Numerical Aperture: 0.60 Working Distance: 2.7–4.0 mm Superb image quality Image quality Microscope objectives may be the most important components of a microscope because they are responsible for primary image formation
  • High image quality is crucial to experimental success and often a requirement for publication; Olympus objectives afford that quality across the visible spectrum to near infrared light
  • This performance results from years of lens manufacture experience, and the broad selection of objectives means that you can choose the optimal objective for your imaging requirements
  • Objective classes Achromat objectives are perfect for general applications, with standard correction of color and focus
  • Fluorite objectives deliver excellent resolution and are made with higher numerical apertures than achromat objectives, resulting in brighter fluorescence signal and higher contrast imaging
  • The higher optical quality greatly reduces optical aberrations, and corrections for color and focus are at higher levels than achromat objectives
  • Fluorite objectives are ideally suited for fluorescence and demanding transmitted light applications, where the higher contrast make them ideally suited for color imaging
  • Apochromat objectives are manufactured to the highest levels of resolution, fluorescence brightness, and contrast; chromatic aberrations are almost eliminated
  • They are recommended for the most demanding applications, particularly at magnifications of 60x and above
  • Apochromatic objectives are the best choice for the capture of color images in white light
  • Brightfield contrast versus phase contrast objectives Brightfield is the most basic form of light microscopy and is accomplished by sample absorption of light
  • A higher density area in a sample will absorb more light, thus increasing contrast in those areas
  • Phase contrast objectives are most useful for hard to see, translucent specimens
  • This method of contrast is accomplished by converting phase shifts, caused by light passing through a translucent specimen, into brightness changes (i.e., contrast)
  • Long working distance versus coverslip-corrected objectives Long working distance (LWD) objectives are optimized for use through vessels with a nominal wall thickness of 0.9-1.5 mm
  • This includes vessels commonly used in cell culture and cell-based assays, such as slides, cell culture dishes and flasks, microtiter well plates, etc
  • Coverslip-corrected objectives are optimized for use through #1.5 coverslips (thickness approximately 0.17 mm)
  • These objectives have a higher magnification/NA ratio and provide higher resolution compared to LWD objectives
  • For additional choices, visit the EVOS objectives selection guide
  • Explore the entire EVOS line of imaging systems and accessories

Compare Similar Items

Show Difference

Img

Invitrogen™

12-563-709

--


Type:
Objective Lens

For Use With (Equipment):
EVOS™

Lens Type:
Fluorite with correction collar

Quantity:
1 each

Product Line:
Olympus

Includes:
Vessels, Slides, Cell Culture Dishes, Flasks, Microtiter Well Plates

Magnification Power:
40X

Shipping Condition:
Room Temperature

Img

Thermo Scientific™

12-563-710

--


Type:
Power Cord

For Use With (Equipment):
EVOS™ FL Color Imaging System, EVOS™ XL Imaging System, EVOS™ FL Imaging System, EVOS™ FL Auto Imaging System

Lens Type:
__

Quantity:
1 Ea.

Product Line:
EVOS

Includes:
__

Magnification Power:
__

Shipping Condition:
__

Img

Thermo Scientific™

12-563-711

--


Type:
Power Cord

For Use With (Equipment):
EVOS™ FL Color Imaging System, EVOS™ XL Imaging System, EVOS™ FL Imaging System, EVOS™ FL Auto Imaging System

Lens Type:
__

Quantity:
1 each

Product Line:
EVOS

Includes:
__

Magnification Power:
__

Shipping Condition:
__

Img

Thermo Scientific™

12-563-712

--


Type:
Power Cord

For Use With (Equipment):
EVOS™ FL Color Imaging System, EVOS™ XL Imaging System, EVOS™ FL Imaging System, EVOS™ FL Auto Imaging System

Lens Type:
__

Quantity:
1 each

Product Line:
EVOS

Includes:
__

Magnification Power:
__

Shipping Condition:
__