43-713-53

Applied Biosystems™ TaqMan™ Genotyping Master Mix

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 43-713-53-Each-of-1 In Stock ₹ 10,780.56

43-713-53 - Each of 1

₹ 10,780.56

In Stock

Quantity

1

Base Price: ₹ 10,780.56

GST (18%): ₹ 1,940.501

Total Price: ₹ 12,721.061

Content And Storage

Supplied at 2X concentration. The mix is optimized for SNP genotyping using TaqMan™ probes and contains AmpliTaq Gold™ DNA Polymerase UP (Ultra Pure), dNTPs without dUTP, Passive Reference 1 and optimized mix components. This pack contains one 1 mL tube, sufficient for 40 reactions at the 50 μL total volume.Storage: 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

GC-Rich PCR Performance

High

Polymerase

AmpliTaq Gold DNA Polymerase

Technique

SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation)

Genotyping Target

Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known)

Product Line

TaqMan™

Purity or Quality Grade

UP (Ultra Pure)

For Use With (Application)

Genotyping

Fidelity (vs. Taq)

2 X

Volume

1 mL

Detection Method

Primer-probe

PCR Method

qPCR

Reaction Speed

Standard

For Use With (Equipment)

Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7

Passive Reference Dye

ROX (Pre-mixed)

Product Type

Genotyping Master Mix

Quantity

1 x 1 mL

Concentration

2X

Sample Type

DNA (Genomic)

Related Products

Img

Fischer Scientific

43-713-55

--

Img

Fischer Scientific

43-816-56

--

Img

Fischer Scientific

43-816-57

--

Img

Fischer Scientific

43-713-57

--

Img

Fischer Scientific

44-033-11

--

Img

Fischer Scientific

44-018-92

--

Img

Fischer Scientific

44-018-90

--

Img

Fischer Scientific

7083422

Optimized for end-point fluorescenc...

Description

  • Distinct clusters and high call rates for unambiguous allelic discrimination Validated with TaqMan™ SNP Genotyping Assays Excellent pre- and post-PCR stability for high throughput setup and analysis Reaction size is based on a 50μL reaction volume May be used for a variety of genotyping applications, including: Candidate gene studies Drug-target validation Disease association studies Population genetics Linkage mapping Agricultural applications Exceptional Performance from an Optimized Mix (2X) Accurate genotype assignments result from preferential binding of the allele-specific probe to the matching target
  • TaqMan™ Genotyping Master Mix enables specific binding of the probe to achieve exceptional cluster resolution
  • Key features include: AmpliTaq Gold™ DNA Polymerase, UP (Ultra Pure) - Automatic hot start enzyme designed to be active during thermal cycling and inactive at room temperature for easy reaction setup Optimized mix components provide excellent specificity for discrimination between alleles Passive internal reference based on proprietary ROX™ dye for increased precision on Applied Biosystems™ real-time PCR instruments Single thermal cycling condition for consistent results with TaqMan™ Assays Validated with TaqMan™ Genotyping Assays and Instruments: TaqMan™ Genotyping Master Mix has been tested across all types of TaqMan™ SNP Genotyping Assays: TaqMan™ Drug Metabolism Genotyping Assays, TaqMan™ SNP Genotyping Assays, and Custom TaqMan™ SNP Genotyping Assays In addition, the master mix is validated with the Applied Biosystems™ thermal cyclers and real-time PCR systems High-Throughput Setup and Analysis: The combination of several low-cost thermal cyclers for PCR and a single real-time PCR instrument for allelic discrimination make high throughput SNP genotyping manageable TaqMan™ Genotyping Master Mix further improves high-throughput setup and analysis with excellent room temperature stability both before and after PCR This provides the flexibility required to run long experiments, unattended overnight or over a weekend Reliable Discrimination with Challenging Targets Amplicon design constraints make SNP detection challenging, particularly when targets contain an abundance of GC- or AT-rich regions The optimized components of TaqMan™ Genotyping Master Mix result in tight, well-separated clusters and more accurate allele-calls compared to other mixes, even for challenging targets Setting the Industry Standard for Quality: Extensive analytical and functional tests are performed for each manufactured lot of TaqMan™ Genotyping Master Mix, including one TaqMan™ SNP Genotyping Assay and one TaqMan™ Drug Metabolism Genotyping Assay Results are compiled in an informative Certificate of Analysis, which is accessible through the Applied Biosystems™ Web site Order Info Guaranteed minimum shelf life is 60 days
  • Shipping Conditions: Wet Ice

Compare Similar Items

Show Difference

Img

Fischer Scientific

43-713-53

--


Content And Storage:
Supplied at 2X concentration. The mix is optimized for SNP genotyping using TaqMan™ probes and contains AmpliTaq Gold™ DNA Polymerase UP (Ultra Pure), dNTPs without dUTP, Passive Reference 1 and optimized mix components. This pack contains one 1 mL tube, sufficient for 40 reactions at the 50 μL total volume.Storage: 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

GC-Rich PCR Performance:
High

Polymerase:
AmpliTaq Gold DNA Polymerase

Technique:
SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation)

Genotyping Target:
Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known)

Product Line:
TaqMan™

Purity or Quality Grade:
UP (Ultra Pure)

For Use With (Application):
Genotyping

Fidelity (vs. Taq):
2 X

Volume:
1 mL

Detection Method:
Primer-probe

PCR Method:
qPCR

Reaction Speed:
Standard

For Use With (Equipment):
Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7

Passive Reference Dye:
ROX (Pre-mixed)

Product Type:
Genotyping Master Mix

Quantity:
1 x 1 mL

Concentration:
2X

Sample Type:
DNA (Genomic)

Img

Fischer Scientific

43-713-55

--


Content And Storage:
Supplied at 2X concentration. The mix is optimized for SNP genotyping using TaqMan™ probes and contains AmpliTaq Gold™ DNA Polymerase UP (Ultra Pure), dNTPs without dUTP, Passive Reference 1 and optimized mix components. This pack contains one 10 mL bottle, sufficient for 400 reactions at the 50 μL total volume.Storage: 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

GC-Rich PCR Performance:
High

Polymerase:
AmpliTaq Gold DNA Polymerase

Technique:
SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation)

Genotyping Target:
Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known)

Product Line:
TaqMan™

Purity or Quality Grade:
UP (Ultra Pure)

For Use With (Application):
Genotyping

Fidelity (vs. Taq):
2 X

Volume:
10 mL

Detection Method:
Primer-probe

PCR Method:
qPCR

Reaction Speed:
Standard

For Use With (Equipment):
Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7

Passive Reference Dye:
ROX (Pre-mixed)

Product Type:
Genotyping Master Mix

Quantity:
1 x 10 mL

Concentration:
2X

Sample Type:
DNA (Genomic)

Img

Fischer Scientific

43-713-57

--


Content And Storage:
Supplied at 2X concentration. The mix is optimized for SNP genotyping using TaqMan™ probes and contains AmpliTaq Gold™ DNA Polymerase UP (Ultra Pure), dNTPs without dUTP, Passive Reference 1 and optimized mix components. This pack contains one 50 mL bottle, sufficient for 2,000 reactions at the 50 μL total volume.Storage: 2-8°CGuaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA).

GC-Rich PCR Performance:
High

Polymerase:
AmpliTaq Gold DNA Polymerase

Technique:
SNP Genotyping (Real-Time PCR-Based), CNV (Copy Number Variation)

Genotyping Target:
Copy Number Variants, SNPs (Unknown or Numerous), Drug Metabolizing Enzymes, SNPs (Known)

Product Line:
TaqMan™

Purity or Quality Grade:
UP (Ultra Pure)

For Use With (Application):
Genotyping

Fidelity (vs. Taq):
2 X

Volume:
50 mL

Detection Method:
Primer-probe

PCR Method:
qPCR

Reaction Speed:
Standard

For Use With (Equipment):
Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7

Passive Reference Dye:
ROX (Pre-mixed)

Product Type:
Genotyping Master Mix

Quantity:
1 x 50 mL

Concentration:
2X

Sample Type:
DNA (Genomic)

Img

Applied Biosystems™

43-714-35

--


Content And Storage:
Includes one background plate and two 96-well fast reaction plates containing spectra dyes (plates I and II). Plate I contains FAM, VIC, NED, and ROX; Plate II contains SYBR Green I, JOE, and TAMRA.Store at -15°C to -25°C. Protect from light.

GC-Rich PCR Performance:
__

Polymerase:
__

Technique:
__

Genotyping Target:
__

Product Line:
StepOnePlus™

Purity or Quality Grade:
__

For Use With (Application):
Real Time PCR (qPCR)

Fidelity (vs. Taq):
__

Volume:
__

Detection Method:
Fluorescence

PCR Method:
__

Reaction Speed:
__

For Use With (Equipment):
Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOnePlus™, Fast Mode, StepOnePlus™, Standard Mode

Passive Reference Dye:
__

Product Type:
Spectral Calibration Kit

Quantity:
1 Kit

Concentration:
__

Sample Type:
__