Content And Storage

5 plates; 3 x 1 mLStore panels at 15–30°C.Store master mix at 5 to -30°C.

Label or Dye

2 Color

Target

Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Candida albicans, Klebsiella pneumoniae, Staphylococcus aureus, coagulase-negative staphylococci, and Staphylococcus saprophyticus

Compatibility

QuantStudio™ 5 Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 5 Dx Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 7 Pro Real-Time PCR System, 96-well, 0.2-mL block

Detection Method

Primer-probe

Quantity

5 Plates

For Use With (Application)

Pathogen Detection

No. of Reactions

Up to 12 Samples/Plate

Related Products

Img

Applied Biosystems™

A56290C

--

Img

Applied Biosystems™

A56289C

--

Img

Applied Biosystems™

A56292C

--

Img

Applied Biosystems™

A56284C

--

Img

Applied Biosystems™

A34642

--

Img

Applied Biosystems™

A31811

--

Img

Applied Biosystems™

A15870

--

Img

Applied Biosystems™

44-141-66

--

Description

  • The Applied Biosystems TrueMark Urinary I Plus Combo Kit achieves molecular detection through real-time PCR technology, offering an end-to-end workflow for many common infectious disease areas by utilizing the power of QuantStudio real-time PCR systems
  • The combination of a TrueMark panel (included) and a QuantStudio system helps enable rapid, accurate detection and categorization of microorganisms that cause urinary diseases
  • The TrueMark Urinary I Plus panel is composed of convenient, duplexed TaqMan assays that detect Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Candida albicans, Klebsiella pneumoniae, Staphylococcus aureus, coagulase-negative staphylococci, Staphylococcus saprophyticus, and an internal control in the same reaction, utilizing real-time PCR techniques
  • Features of the TrueMark Urinary I Plus panel include: • Ease-of-use —convenient, duplexed reactions include assay and positive control, pre-spotted and dried down on TaqMan plates, designed for easy setup and increased accuracy; just add sample and TrueMark Infectious Disease Panels 1-Step Multiplex Master Mix (No ROX) (included) • Endogenous controls —duplex reactions offer RNase P human internal control in every well for added confidence • Turn-around time —choose from a selection of predefined panels with a short turn-around time • Amplification control —TrueMark Amplification Control I covers all targets in RTI, UTI, STI, and vaginal panels • Maximize the workflow —expand from SARS-CoV-2 testing to TrueMark infectious disease research panels utilizing the same workflow The TrueMark Urinary I Plus Combo Kit includes the following components: • TrueMark Urinary I Plus Panel —collection of duplex assays that contain primer/probe sets specific to Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Candida albicans, Klebsiella pneumoniae, Staphylococcus aureus, coagulase-negative staphylococci, Staphylococcus saprophyticus, and RNase P genomic regions • TrueMark Infectious Disease Panels 1-Step Multiplex Master Mix (No ROX) —ready-to-use PCR mix, including reverse transcriptase, polymerase, dNTPs, salt, and buffer The TrueMark Urinary I Plus Combo Kit is used with nasopharyngeal swab or nasopharyngeal aspirate samples on our QuantStudio real-time PCR systems
  • Product use The TrueMark Urinary I Plus Panel is a collection of duplex assays that detect microbes and an internal control in the same reaction for qualitative detection and identification of Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Candida albicans, Klebsiella pneumoniae, Staphylococcus aureus, coagulase-negative staphylococci, Staphylococcus saprophyticus in urine samples obtained from individuals exhibiting signs and symptoms of a urinary tract infection.

Compare Similar Items

Show Difference

Img

Applied Biosystems™

A56288C

--


Content And Storage:
5 plates; 3 x 1 mLStore panels at 15–30°C.Store master mix at 5 to -30°C.

Label or Dye:
2 Color

Target:
Pseudomonas aeruginosa, Escherichia coli, Proteus mirabilis, Candida albicans, Klebsiella pneumoniae, Staphylococcus aureus, coagulase-negative staphylococci, and Staphylococcus saprophyticus

Compatibility:
QuantStudio™ 5 Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 5 Dx Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 7 Pro Real-Time PCR System, 96-well, 0.2-mL block

Detection Method:
Primer-probe

Quantity:
5 Plates

For Use With (Application):
Pathogen Detection

No. of Reactions:
Up to 12 Samples/Plate

Img

Applied Biosystems™

A56289C

--


Content And Storage:
5 plates; 3 x 1 mLStore panels at 15–30°C.Store master mix at 5 to -30°C.

Label or Dye:
2 Color

Target:
Corynebacterium riegelii, Enterobacter aerogenes, Aerococcus urinae, Proteus vulgaris, Acinetobacter baumannii, Actinobaculum schaalii, Enterococcus faecalis, and Streptococcus agalactiae

Compatibility:
QuantStudio™ 5 Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 5 Dx Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 7 Pro Real-Time PCR System, 96-well, 0.2-mL block

Detection Method:
Primer-probe

Quantity:
1 kit

For Use With (Application):
Pathogen Detection

No. of Reactions:
Up to 12 Samples/Plate

Img

Applied Biosystems™

A56290C

--


Content And Storage:
5 plates; 3 x 1 mLStore panels at 15–30°C.Store master mix at 5 to -30°C.

Label or Dye:
2 Color

Target:
Citrobacter freundii, Enterobacter cloacae, Enterococcus faecium, Klebsiella oxytoca, Serratia marcescens, Mycoplasma hominis, Morganella morganii, and Providencia stuartii

Compatibility:
QuantStudio™ 5 Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 5 Dx Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 7 Pro Real-Time PCR System, 96-well, 0.2-mL block

Detection Method:
Primer-probe

Quantity:
5 Plates

For Use With (Application):
Pathogen Detection

No. of Reactions:
Up to 12 Samples/Plate

Img

Applied Biosystems™

A56292C

--


Content And Storage:
5 plates; 3 x 1 mLStore panels at 15–30°C.Store master mix at 5 to -30°C.

Label or Dye:
2 Color

Target:
Gardnerella vaginalis, Atopobium vaginae, Prevotella bivia, Mobiluncus curtisii, Bacteroides fragilis, Pan-Lactobacillus, Megasphaera Type 1, and bacterial vaginosis-associated bacteria 2 (BVAB2)

Compatibility:
QuantStudio™ 5 Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 5 Dx Real‐Time PCR System, 96-well, 0.2-mL block; QuantStudio™ 7 Pro Real-Time PCR System, 96-well, 0.2-mL block

Detection Method:
Primer-probe

Quantity:
5 Plates

For Use With (Application):
Pathogen Detection

No. of Reactions:
Up to 12 Samples/Plate