43-654-64

Applied Biosystems™ 7500 Fast Real-Time PCR System, laptop, QST

Manufacturer: Applied Biosystems™

The price for this product is unavailable. Please request a quote

Format

96-well Plate

Sample Ramp Rate

Fast Mode: ± 2.2°C⁄s, Standard mode: ± 1.6°C⁄s

Temperature Range (Metric)

4 to 100°C

Passive Reference Dye

ROX (Separate Tube), ROX (Pre-mixed)

Content And Storage

Laptop

High-throughput Compatibility

High-throughput Compatible, Multiplexing

Thermal Uniformity

Within 1.0°C (30 s after Clock Start)

Throughput

Manual Loading of four-five 96-well Plates per 8-hr day (Real Time throughput)

Thermal Cycling System

Peltier-based System

External Computer

Minitower

Software Compatibility

Primer Express Software, System Software

Voltage

120 V

Quantity

1 system

Thermal Accuracy

Within 0.5°C (35° to 95°C) of Setpoint/Display Temp. (3 min. after start)

Sensitivity

Down to 1 Copy of Human RNAse P gene

Reaction Volume Range

10-30 μL

Dynamic Range

9 Logs of Linear Dynamic Range

Calibrated Dye

SYBR™ Green I, ROX™, NED™, TAMRA™, JOE™, Texas Red™, Cy5™, VIC™, FAM™, Cy3™

For Use With (Equipment)

7500 Fast System

Reaction Speed

Fast, Standard

Optics

Tungsten-halogen Lamp, Five-Emission Filters and CCD Camera, Five-Excitation Filters

Dimensions

34 cm (W) x 49 cm (H) x 45 cm (D) (13.39 in. x 19.29 in. x 17.72 in.)

Data Acquisition

Collects Data for all 5 Filters for all Wells regardless of Plate Setup

Precision

Can distinguish between 5000 and 10000 Template Copies with 99.7% Confidence

Electrical Requirements

950 W

Weight

34 kg (75 lb.)

Related Products

Img

Applied Biosystems™

43-511-07

--

Img

Applied Biosystems™

43-765-98

--

Img

Applied Biosystems™

43-766-00

--

Img

Fischer Scientific

50-257-6129

--

Img

Fischer Scientific

A27925

--

Img

Applied Biosystems™

44-710-89

--

Img

Applied Biosystems™

44-711-34

--

Img

Thermo Scientific

RA30299

--

Description

  • It is a sophisticated platform for users who require extended capabilities and maximum versatility
  • The 3rd generation platform features an innovative optical system that enhances sensitivity and lets you access a broader range of fluorophores
  • The variable excitation capability allows greater sensitivity for longer wavelength (red) dyes
  • NEW - 7500 Software v2.0: Now the easy-to-use StepOne software is available for both the 7500 and 7500 Fast systems with the 7500 Software v2.0 upgrade
  • The 7500 Software v2.0 incorporates your favorite StepOne Software features, such as multiple plate setup wizards, calculators for standard curve dilution and master mix recipes, QCX3 flags, data filters, and email notification when a run is finished
  • The 7500 Software v2.0 also includes an enhanced Gene Expression Study package and has a variety of new melting curve protocol options, including multiple peak detection, step and hold temperature control, and customizable ramp rates
  • The NEW Gene Expression Study package accommodates large studies better than any other instrument software package: Import an unlimited number of Comparative CT (relative quantitation) files to one study Group samples and view data both by technical replicate group and biological replicate group Use any gene(s) as an endogenous control, including averaging multiple controls together Enter known efficiency values to be factored into the RQ results 21 CFR Part 11 Module available: The SDS v1.4 21CFRp11 Module is a powerful tool for assisting with 21CFRp11 compliance, while still offering the flexibility of user-customizable configuration settings
  • Individual user log-ins can be added for up to four user groups, each group with designated permission settings User-customizable permission settings include fourteen system activities, e-signature authority designation, and additional security settings to give you maximum control over your compliance efforts Audit trails can be enabled or disabled depending on your traceability needs A selection of e-signatures is available to ease e-signatures into your workflow Supports Many Applications: Applications include gene expression analysis, pathogen quantitation, SNP genotyping, isothermal and +⁄– assays utilizing internal positive controls
  • To facilitate many of these applications, we provide preformulated, ready-to-use, quality-tested, TaqMan™ assays for use with the 7500 system
  • Now you can reduce your assay optimization efforts
  • Upgrade to High-Speed Thermal Cycling: An optional upgrade to a the 7500 Fast System is available
  • This 7500 Fast System uses our master mix formulations and enables you to shorten your real-time PCR runs to as little as 30 minutes
  • For Research Use Only
  • Not for use in diagnostics procedures.

Compare Similar Items

Show Difference

Img

Applied Biosystems™

43-654-64

--


Format:
96-well Plate

Sample Ramp Rate:
Fast Mode: ± 2.2°C⁄s, Standard mode: ± 1.6°C⁄s

Temperature Range (Metric):
4 to 100°C

Passive Reference Dye:
ROX (Separate Tube), ROX (Pre-mixed)

Content And Storage:
Laptop

High-throughput Compatibility:
High-throughput Compatible, Multiplexing

Thermal Uniformity:
Within 1.0°C (30 s after Clock Start)

Throughput:
Manual Loading of four-five 96-well Plates per 8-hr day (Real Time throughput)

Thermal Cycling System:
Peltier-based System

External Computer:
Minitower

Software Compatibility:
Primer Express Software, System Software

Voltage:
120 V

Quantity:
1 system

Thermal Accuracy:
Within 0.5°C (35° to 95°C) of Setpoint/Display Temp. (3 min. after start)

Sensitivity:
Down to 1 Copy of Human RNAse P gene

Reaction Volume Range:
10-30 μL

Dynamic Range:
9 Logs of Linear Dynamic Range

Calibrated Dye:
SYBR™ Green I, ROX™, NED™, TAMRA™, JOE™, Texas Red™, Cy5™, VIC™, FAM™, Cy3™

For Use With (Equipment):
7500 Fast System

Reaction Speed:
Fast, Standard

Optics:
Tungsten-halogen Lamp, Five-Emission Filters and CCD Camera, Five-Excitation Filters

Dimensions:
34 cm (W) x 49 cm (H) x 45 cm (D) (13.39 in. x 19.29 in. x 17.72 in.)

Data Acquisition:
Collects Data for all 5 Filters for all Wells regardless of Plate Setup

Precision:
Can distinguish between 5000 and 10000 Template Copies with 99.7% Confidence

Electrical Requirements:
950 W

Weight:
34 kg (75 lb.)

Img

LIFE TECHNOLOGIES

43-654-81R

--


Format:
__

Sample Ramp Rate:
__

Temperature Range (Metric):
__

Passive Reference Dye:
__

Content And Storage:
__

High-throughput Compatibility:
__

Thermal Uniformity:
__

Throughput:
__

Thermal Cycling System:
__

External Computer:
__

Software Compatibility:
__

Voltage:
__

Quantity:
__

Thermal Accuracy:
__

Sensitivity:
__

Reaction Volume Range:
__

Dynamic Range:
__

Calibrated Dye:
__

For Use With (Equipment):
__

Reaction Speed:
__

Optics:
__

Dimensions:
__

Data Acquisition:
__

Precision:
__

Electrical Requirements:
__

Weight:
__

Img

LIFE TECHNOLOGIES

43-655-41

--


Format:
__

Sample Ramp Rate:
__

Temperature Range (Metric):
__

Passive Reference Dye:
__

Content And Storage:
__

High-throughput Compatibility:
__

Thermal Uniformity:
__

Throughput:
__

Thermal Cycling System:
__

External Computer:
__

Software Compatibility:
__

Voltage:
__

Quantity:
__

Thermal Accuracy:
__

Sensitivity:
__

Reaction Volume Range:
__

Dynamic Range:
__

Calibrated Dye:
__

For Use With (Equipment):
__

Reaction Speed:
__

Optics:
__

Dimensions:
__

Data Acquisition:
__

Precision:
__

Electrical Requirements:
__

Weight:
__

Img

LIFE TECHNOLOGIES

43-663-73

--


Format:
__

Sample Ramp Rate:
__

Temperature Range (Metric):
__

Passive Reference Dye:
__

Content And Storage:
__

High-throughput Compatibility:
__

Thermal Uniformity:
__

Throughput:
__

Thermal Cycling System:
__

External Computer:
__

Software Compatibility:
__

Voltage:
__

Quantity:
__

Thermal Accuracy:
__

Sensitivity:
__

Reaction Volume Range:
__

Dynamic Range:
__

Calibrated Dye:
__

For Use With (Equipment):
__

Reaction Speed:
__

Optics:
__

Dimensions:
__

Data Acquisition:
__

Precision:
__

Electrical Requirements:
__

Weight:
__