13-303-213

Thermo Scientific™ Orion Star™ A322 Conductivity Portable Meter

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 13-303-213-Each-of-1 In Stock ₹ 2,41,040.00

13-303-213 - Each of 1

₹ 2,41,040.00

In Stock

Quantity

1

Base Price: ₹ 2,41,040.00

GST (18%): ₹ 43,387.20

Total Price: ₹ 2,84,427.20

Description

Orion Star A322 conductivity/TDS/salinity/resistivity portable meter kit with pure water conductivity sensor & flow-cell, solutions, meter armor and field case

Outputs

USB, RS232

Measurement Modes

Conductivity, TDS, Salinity, Resistivity with Temperature

Cell Constant

0.001 to 199.9cm-1

Calibration Points (Conductivity)

5

Resolution (Conductivity)

0.001 μS minimum, auto ranging up to 4 significant digits

Temperature (Metric) Reference

5, 10, 15, 20, 25°C

Resolution (Salinity)

0.01 psu or 0.01 ppt minimum, auto ranging

Salinity Measurement Modes

Practical salinity (psu) or natural sea water (ppt)

Accuracy (TDS)

0.5% of reading ±1 digit

Temperature Range (Metric)

-5°C to +105°C

Accuracy (Temperature)

±0.1°C

Temperature Selection

Manual or automatic with ATC temperature probe

Display Type

Graphic LCD with Backlight

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Log Function Type

Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Alarm Output

High/low limit alarm, calibration due alarm

Certifications/Compliance

CE, TUV 3-1, FCC Class A

AC Adapter

Universal 50-60Hz, 100-240VAC power adapter (sold separately, Cat. No. 1010003)

Weight (Metric)

0.5 kg

Probe Type

Conductivity sensor (includes 013016MD Orion pure water 2-cell conductivity sensor)

Model

Orion Star A322 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter

Power Supply

4 AA batteries (included) or universal AC adapter (sold separately)

Stability

Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Languages

English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update

Temperature (Metric) Operating

5°C to 45°C (ambient)

Accuracy (Resistivity)

0.5% of reading ±1 digit

Battery Life

800 hr.

Accuracy (Conductivity)

0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS

Includes

Star A322 conductivity meter, 013016MD Orion pure water (K=0.1) conductivity sensor with flow-cell, 011008 Orion 100 μS conductivity standard, 911110 Orion rinse solution pouch 10 pack, protective meter armor, hard-sided field case, 4 AA batteries, literature CD, printed quick start guide, computer interface cable and meter test certificate

Compatible Probes

2-cell or 4-cell conductivity sensors with built-in temperature

Calibration

Conductivity with calibration editing option and temperature

Range (Conductivity)

0.001 μS/cm to 3000 mS/cm

Temperature Compensation

Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit

Range (Salinity)

0.06 to 80.00 psu, 0.05 to 42.00 ppt

Accuracy (Salinity)

0.5% of reading ±1 digit

Resolution (TDS)

0.001 ppm minimum, auto ranging up to 4 significant digits

TDS Factor Range

Linear (0.02 to 9.99)

Resolution (Temperature)

0.1°C (0.1°F)

Range (Resistivity)

2 ohm to 100.0 megohm

Temperature Probe Calibration

1 point temperature offset calibration

Backlight Option

Yes, selectable

Data Points

5000 with date and time stamp

Data Management Details

Transfer single, range or all data points to printer or computer

Inputs

8 pin MiniDIN (conductivity sensor with built-in temperature)

IP Rating

IP67

Dimensions (L x W x H)

24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.)

Weight (English)

1.2 lb.

Relative Humidity Range

5 to 85%, non-condensing

Resolution (Resistivity)

1 ohm or 0.1 megohm, auto ranging

Methods

10 per channel with password protection

Keypad

Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Temperature (English) Operating

41°F to 113°F (ambient)

Channels

1

Battery Type

4 x AA (included)

Related Products

Img

Fischer Scientific

13-645-554

--

Img

Fischer Scientific

13-645-531

--

Img

Fischer Scientific

13-645-529

--

Img

Fischer Scientific

13-303-206

--

Img

Fischer Scientific

4529312

Accurately monitor conductivity, TD...

Img

Fischer Scientific

13-645-563

--

Img

Fischer Scientific

13-645-575

--

Img

Fischer Scientific

13-645-565

--

Description

  • Description Get high accuracy and premium performance everywhere you need it with the Thermo Scientific™ Orion Star™ A322 Conductivity Portable Meter
  • This instrument is designed for a wide range of conductivity, total dissolved solids (TDS), salinity, resistivity and temperature testing and field applications
  • Evaluate samples in the most demanding locations using this waterproof meter with IP67-rated housing
  • Select linear, non-linear pure water or EP temperature compensation with 5°C, 10°C, 15°C, 20°C or 25°C reference temperatures
  • Log up to 5000 data point sets with time/date stamp and transfer to a printer or computer
  • Take your measurements at the source with our premium line of portable meters
  • The Thermo Scientific Orion Star A322 conductivity portable meter offers an information-rich screen and user-friendly operation
  • This rugged, waterproof portable meter is ready to tackle the elements with you
  • Orion Star A322 conductivity portable meters are designed to be easy-to-use, dependable field meters that offer advanced features and functions including a 5000 point date log with sample ID and user ID options, calibration and high/low limit alarms and password-protected measurement methods
  • Measure conductivity, TDS, salinity or resistivity with temperature Perform up to a five point conductivity calibration with calibration editing option that allows individual points to be fixed without a full recalibration Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate Use linear, non-linear, EP (USP) or off conductivity temperature compensation with 5°C, 10°C, 15°C, 20°C or 25°C reference temperatures Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation Capture your critical readings with measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals Data log collects and date/time stamps up to 5000 measurement sets with optional sample ID and user ID Calibration log stores ten most recent calibrations Non-volatile meter memory ensures your data and settings are protected, even with loss of power Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections Flexible power options with AA batteries or optional universal power adapter IP67-rated housing is waterproof for rugged field operation Meter kits include hard-sided field case and protective meter armor with electrode holders, adjustable wrist/belt strap and built-in meter stand Meters offer CE, TUV 3-in-1 and FCC Class A certifications and 3-year replacement warranty Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Compare Similar Items

Show Difference

Img

Fischer Scientific

13-303-213

--


Description:
Orion Star A322 conductivity/TDS/salinity/resistivity portable meter kit with pure water conductivity sensor & flow-cell, solutions, meter armor and field case

Outputs:
USB, RS232

Measurement Modes:
Conductivity, TDS, Salinity, Resistivity with Temperature

Cell Constant:
0.001 to 199.9cm-1

Calibration Points (Conductivity):
5

Resolution (Conductivity):
0.001 μS minimum, auto ranging up to 4 significant digits

Temperature (Metric) Reference:
5, 10, 15, 20, 25°C

Resolution (Salinity):
0.01 psu or 0.01 ppt minimum, auto ranging

Salinity Measurement Modes:
Practical salinity (psu) or natural sea water (ppt)

Accuracy (TDS):
0.5% of reading ±1 digit

Temperature Range (Metric):
-5°C to +105°C

Accuracy (Temperature):
±0.1°C

Temperature Selection:
Manual or automatic with ATC temperature probe

Display Type:
Graphic LCD with Backlight

Memory:
Non-volatile memory preserves data log, calibration log and meter settings

Log Function Type:
Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m

Alarm Output:
High/low limit alarm, calibration due alarm

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

AC Adapter:
Universal 50-60Hz, 100-240VAC power adapter (sold separately, Cat. No. 1010003)

Weight (Metric):
0.5 kg

Probe Type:
Conductivity sensor (includes 013016MD Orion pure water 2-cell conductivity sensor)

Model:
Orion Star A322 Conductivity/TDS/Salinity/Resistivity/Temperature Portable Meter

Power Supply:
4 AA batteries (included) or universal AC adapter (sold separately)

Stability:
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

Temperature (Metric) Operating:
5°C to 45°C (ambient)

Accuracy (Resistivity):
0.5% of reading ±1 digit

Battery Life:
800 hr.

Accuracy (Conductivity):
0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS

Includes:
Star A322 conductivity meter, 013016MD Orion pure water (K=0.1) conductivity sensor with flow-cell, 011008 Orion 100 μS conductivity standard, 911110 Orion rinse solution pouch 10 pack, protective meter armor, hard-sided field case, 4 AA batteries, literature CD, printed quick start guide, computer interface cable and meter test certificate

Compatible Probes:
2-cell or 4-cell conductivity sensors with built-in temperature

Calibration:
Conductivity with calibration editing option and temperature

Range (Conductivity):
0.001 μS/cm to 3000 mS/cm

Temperature Compensation:
Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit

Range (Salinity):
0.06 to 80.00 psu, 0.05 to 42.00 ppt

Accuracy (Salinity):
0.5% of reading ±1 digit

Resolution (TDS):
0.001 ppm minimum, auto ranging up to 4 significant digits

TDS Factor Range:
Linear (0.02 to 9.99)

Resolution (Temperature):
0.1°C (0.1°F)

Range (Resistivity):
2 ohm to 100.0 megohm

Temperature Probe Calibration:
1 point temperature offset calibration

Backlight Option:
Yes, selectable

Data Points:
5000 with date and time stamp

Data Management Details:
Transfer single, range or all data points to printer or computer

Inputs:
8 pin MiniDIN (conductivity sensor with built-in temperature)

IP Rating:
IP67

Dimensions (L x W x H):
24 x 10 x 6.5 cm (9.5 x 3.9 x 2.6 in.)

Weight (English):
1.2 lb.

Relative Humidity Range:
5 to 85%, non-condensing

Resolution (Resistivity):
1 ohm or 0.1 megohm, auto ranging

Methods:
10 per channel with password protection

Keypad:
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Temperature (English) Operating:
41°F to 113°F (ambient)

Channels:
1

Battery Type:
4 x AA (included)

Img

Fischer Scientific

13-310-148

--


Description:
__

Outputs:
__

Measurement Modes:
__

Cell Constant:
__

Calibration Points (Conductivity):
__

Resolution (Conductivity):
__

Temperature (Metric) Reference:
__

Resolution (Salinity):
__

Salinity Measurement Modes:
__

Accuracy (TDS):
__

Temperature Range (Metric):
__

Accuracy (Temperature):
__

Temperature Selection:
__

Display Type:
__

Memory:
__

Log Function Type:
__

Alarm Output:
__

Certifications/Compliance:
USP Class VI; European Pharmacopoeia (EP 3.2.9); FDA 21 CFR 177.2600; NSF-51; REACH, RoHS compliant

AC Adapter:
__

Weight (Metric):
__

Probe Type:
__

Model:
__

Power Supply:
__

Stability:
__

Temperature (Metric) Operating:
__

Accuracy (Resistivity):
__

Battery Life:
__

Accuracy (Conductivity):
__

Includes:
__

Compatible Probes:
__

Calibration:
__

Range (Conductivity):
__

Temperature Compensation:
__

Range (Salinity):
__

Accuracy (Salinity):
__

Resolution (TDS):
__

TDS Factor Range:
__

Resolution (Temperature):
__

Range (Resistivity):
__

Temperature Probe Calibration:
__

Backlight Option:
__

Data Points:
__

Data Management Details:
__

Inputs:
__

IP Rating:
__

Dimensions (L x W x H):
__

Weight (English):
__

Relative Humidity Range:
__

Resolution (Resistivity):
__

Methods:
__

Keypad:
__

Temperature (English) Operating:
__

Channels:
__

Battery Type:
__

Img

Fischer Scientific

13-310-155

--


Description:
__

Outputs:
__

Measurement Modes:
__

Cell Constant:
__

Calibration Points (Conductivity):
__

Resolution (Conductivity):
__

Temperature (Metric) Reference:
__

Resolution (Salinity):
__

Salinity Measurement Modes:
__

Accuracy (TDS):
__

Temperature Range (Metric):
__

Accuracy (Temperature):
__

Temperature Selection:
__

Display Type:
__

Memory:
__

Log Function Type:
__

Alarm Output:
__

Certifications/Compliance:
USP Class VI; European Pharmacopoeia (EP 3.2.9); FDA 21 CFR 177.2600; NSF-51; REACH, RoHS compliant

AC Adapter:
__

Weight (Metric):
__

Probe Type:
__

Model:
__

Power Supply:
__

Stability:
__

Temperature (Metric) Operating:
__

Accuracy (Resistivity):
__

Battery Life:
__

Accuracy (Conductivity):
__

Includes:
__

Compatible Probes:
__

Calibration:
__

Range (Conductivity):
__

Temperature Compensation:
__

Range (Salinity):
__

Accuracy (Salinity):
__

Resolution (TDS):
__

TDS Factor Range:
__

Resolution (Temperature):
__

Range (Resistivity):
__

Temperature Probe Calibration:
__

Backlight Option:
__

Data Points:
__

Data Management Details:
__

Inputs:
__

IP Rating:
__

Dimensions (L x W x H):
__

Weight (English):
__

Relative Humidity Range:
__

Resolution (Resistivity):
__

Methods:
__

Keypad:
__

Temperature (English) Operating:
__

Channels:
__

Battery Type:
__

Img

Fischer Scientific

13-311-299

--


Description:
Standard glass bulb Immersion probe

Outputs:
__

Measurement Modes:
__

Cell Constant:
__

Calibration Points (Conductivity):
__

Resolution (Conductivity):
__

Temperature (Metric) Reference:
__

Resolution (Salinity):
__

Salinity Measurement Modes:
__

Accuracy (TDS):
__

Temperature Range (Metric):
0°C to 50°C

Accuracy (Temperature):
±0.5°C;/±0.9°F

Temperature Selection:
__

Display Type:
LCD, Dual-Line

Memory:
__

Log Function Type:
__

Alarm Output:
__

Certifications/Compliance:
CE; IP67

AC Adapter:
__

Weight (Metric):
__

Probe Type:
Immersion

Model:
5

Power Supply:
__

Stability:
__

Temperature (Metric) Operating:
__

Accuracy (Resistivity):
__

Battery Life:
400 hr.

Accuracy (Conductivity):
__

Includes:
pH Tester, protective plastic storage case, lanyard, and four AAA batteries.

Compatible Probes:
__

Calibration:
USA, NIST

Range (Conductivity):
__

Temperature Compensation:
Automatic

Range (Salinity):
__

Accuracy (Salinity):
__

Resolution (TDS):
__

TDS Factor Range:
__

Resolution (Temperature):
0.1°F/°C

Range (Resistivity):
__

Temperature Probe Calibration:
__

Backlight Option:
__

Data Points:
__

Data Management Details:
__

Inputs:
__

IP Rating:
IP67

Dimensions (L x W x H):
__

Weight (English):
__

Relative Humidity Range:
__

Resolution (Resistivity):
__

Methods:
__

Keypad:
__

Temperature (English) Operating:
__

Channels:
1

Battery Type:
4 AAA