15-200-972

Thermo Scientific™ Orion Lab Star EC112 Conductivity Bench Meters

Manufacturer: Fischer Scientific

Select a Size

Pack Size SKU Availability Price
Each of 1 15-200-972-Each-of-1 In Stock ₹ 76,961.22

15-200-972 - Each of 1

₹ 76,961.22

In Stock

Quantity

1

Base Price: ₹ 76,961.22

GST (18%): ₹ 13,853.02

Total Price: ₹ 90,814.24

Description

Orion Lab Star EC112 conductivity/salinity/TDS bench meter with stand

Outputs

Computer or printer (STARA-106)

For Use With (Application)

Meter and Stand Option, Select and Purchase The Electrode Separately

Compatible Probes

2-cell and 4-cell conductivity electrodes

Calibration

Conductivity, salinity, TDS and temperature

Calibration Points

1 point salinity, 1-5 points TDS, 1 point temperature

Resolution (Conductivity)

0.01, 0.1, 1 μS; 0.01, 0.1 mS

Temperature Coefficient

0 to 10 %/°C

Range (Salinity)

0.00 to 80.0 ppt; 0.00 to 42.0 PSU

Accuracy (Salinity)

±0.5 % of the reading ± 1 LSD

Resolution (TDS)

0.01, 0.1, 1 ppm; 0.01, 0.1 ppt

TDS Factor Range

0.40 to 1.00

Temperature Range (English)

23.0°F to 221.0°F

Accuracy (Temperature)

±0.3°C, ±0.5°F

Temperature Probe Calibration

1 point temperature offset calibration

Backlight Option

Yes

Data Points

500 data sets with time and date

Data Management Details

Continuous, Auto-Read and Timed read modes

Inputs

8-pin MiniDIN for conductivity with built-in ATC

IP Rating

IP54

Dimensions (L x W x H)

187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.

Weight (English)

1.54 lb.

Accuracy (Conductivity)

±0.5 % of the reading ± 1 LSD

Includes

Meter with electrode stand, PC cable, universal power adapter

Measurement Modes

Conductivity with Temperature, Salinity with Temperature, TDS with Temperature

Cell Constant

0.100 to 10.00 cm-1

Calibration Points (Conductivity)

1-5 points conductivity

Range (Conductivity)

0.00 μS to 500.0 mS

Temperature Compensation

Linear (0 to 10 %/°C) or off

Temperature (Metric) Reference

15.0, 20.0, 25.0 or 30.0°C

Resolution (Salinity)

0.01, 0.1 ppt; 0.01, 0.1 PSU

Salinity Measurement Modes

Natural Seawater (ppt) or Practical Salinity (PSU)

Accuracy (TDS)

±0.5 % of the reading ± 1 LSD

Temperature Range (Metric)

-5.0°C to +105.0°C

Resolution (Temperature)

0.1°C, 0.1°F

Temperature Selection

Manual or automatic with ATC temperature probe

Display Type

5 in. backlit LCD

Memory

Non-volatile

Log Function Type

Automatic with Auto-Read and Timed read modes, manual with Continuous read mode

Alarm Output

Calibration reminder alarm

Certifications/Compliance

CE, TUV 3-1, FCC Class A

AC Adapter

Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

Weight (Metric)

700 grams

Warranty

3 year meter warranty

Related Products

Img

Fischer Scientific

15-200-973

--

Img

Fischer Scientific

7224960

Orion Lab Star EC112 conductivity b...

Img

Thermo Scientific™

15-200-973PM

--

Img

Fischer Scientific

15-200-974

--

Img

Fischer Scientific

15-200-975

--

Img

Thermo Scientific™

15-200-975PM

--

Img

Fischer Scientific

4529310

Reliably measure conductivity, TDS,...

Img

Fischer Scientific

7224961

Orion Lab Star DO113 dissolved oxyg...

Description

  • Measure conductivity, salinity or total dissolved solids with temperature using the Orion Lab Star EC112 conductivity bench meter
  • Featuring a large, backlit display for easy viewability and small footprint to save space, this meter is ideal for simplified, budget-friendly lab testing
  • Use the onscreen stabilizing and ready indicators to help identify when conductivity meter, salinity meter and TDS meter readings are complete
  • View active calibration logs with date and time, record key measurements using the 500-point data log with date and time, and output all logs to a printer or computer
  • Orion Lab Star EC112 Conductivity Meter Features Budget-friendly conductivity meter for simplified conductivity, salinity and TDS testing Display shows conductivity, cell constant, temperature and temperature coefficient simultaneously for accurate data recording Measure 0.00 μS to 500.0 mS conductivity, 0.00 to 80.0 ppt or 0.00 to 42.0 PSU salinity, 0.00 ppm to 500.0 ppt TDS and -5.0 to 105.0 °C or 23.0 to 221.0 °F to ensure comprehensive measurement capabilities Perform one to five point conductivity and TDS calibrations, one point salinity calibrations and one point temperature adjustment calibrations for proficient SOP compliance Large 5 inch backlit display makes viewing and recording measurements easy Small meter footprint saves valuable bench space in your lab Onscreen stabilizing and ready indicators help identify when readings are complete Date and time data stamped data and calibration logs support GLP compliance View active conductivity, salinity, TDS and temperature calibration logs with date and time stamp to ensure accurate, reproducible measurements Use 500-point data log with date and time stamp to record key measurements Output data and calibration logs to a printer or computer for long-term data storage Meter and Meter Kits LSTAR1120 is the conductivity meter and stand option, which allows you to purchase your conductivity electrode separately LSTAR1125 is the standard conductivity meter kit option, for common conductivity samples in a wide range of 1 μS/cm to 20 mS/cm

Compare Similar Items

Show Difference

Img

Fischer Scientific

15-200-972

--


Description:
Orion Lab Star EC112 conductivity/salinity/TDS bench meter with stand

Outputs:
Computer or printer (STARA-106)

For Use With (Application):
Meter and Stand Option, Select and Purchase The Electrode Separately

Compatible Probes:
2-cell and 4-cell conductivity electrodes

Calibration:
Conductivity, salinity, TDS and temperature

Calibration Points:
1 point salinity, 1-5 points TDS, 1 point temperature

Resolution (Conductivity):
0.01, 0.1, 1 μS; 0.01, 0.1 mS

Temperature Coefficient:
0 to 10 %/°C

Range (Salinity):
0.00 to 80.0 ppt; 0.00 to 42.0 PSU

Accuracy (Salinity):
±0.5 % of the reading ± 1 LSD

Resolution (TDS):
0.01, 0.1, 1 ppm; 0.01, 0.1 ppt

TDS Factor Range:
0.40 to 1.00

Temperature Range (English):
23.0°F to 221.0°F

Accuracy (Temperature):
±0.3°C, ±0.5°F

Temperature Probe Calibration:
1 point temperature offset calibration

Backlight Option:
Yes

Data Points:
500 data sets with time and date

Data Management Details:
Continuous, Auto-Read and Timed read modes

Inputs:
8-pin MiniDIN for conductivity with built-in ATC

IP Rating:
IP54

Dimensions (L x W x H):
187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.

Weight (English):
1.54 lb.

Accuracy (Conductivity):
±0.5 % of the reading ± 1 LSD

Includes:
Meter with electrode stand, PC cable, universal power adapter

Measurement Modes:
Conductivity with Temperature, Salinity with Temperature, TDS with Temperature

Cell Constant:
0.100 to 10.00 cm-1

Calibration Points (Conductivity):
1-5 points conductivity

Range (Conductivity):
0.00 μS to 500.0 mS

Temperature Compensation:
Linear (0 to 10 %/°C) or off

Temperature (Metric) Reference:
15.0, 20.0, 25.0 or 30.0°C

Resolution (Salinity):
0.01, 0.1 ppt; 0.01, 0.1 PSU

Salinity Measurement Modes:
Natural Seawater (ppt) or Practical Salinity (PSU)

Accuracy (TDS):
±0.5 % of the reading ± 1 LSD

Temperature Range (Metric):
-5.0°C to +105.0°C

Resolution (Temperature):
0.1°C, 0.1°F

Temperature Selection:
Manual or automatic with ATC temperature probe

Display Type:
5 in. backlit LCD

Memory:
Non-volatile

Log Function Type:
Automatic with Auto-Read and Timed read modes, manual with Continuous read mode

Alarm Output:
Calibration reminder alarm

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

AC Adapter:
Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

Weight (Metric):
700 grams

Warranty:
3 year meter warranty

Img

Fischer Scientific

15-200-973

--


Description:
Orion Lab Star EC112 conductivity/salinity/TDS bench meter standard kit

Outputs:
Computer or printer (STARA-106)

For Use With (Application):
For a Wide Variety of Conductivity Samples in The 1 μS/cm to 20 mS/cm Range

Compatible Probes:
2-cell and 4-cell conductivity electrodes

Calibration:
Conductivity, salinity, TDS and temperature

Calibration Points:
1 point salinity, 1-5 points TDS, 1 point temperature

Resolution (Conductivity):
0.01, 0.1, 1 μS; 0.01, 0.1 mS

Temperature Coefficient:
0 to 10 %/°C

Range (Salinity):
0.00 to 80.0 ppt; 0.00 to 42.0 PSU

Accuracy (Salinity):
±0.5 % of the reading ± 1 LSD

Resolution (TDS):
0.01, 0.1, 1 ppm; 0.01, 0.1 ppt

TDS Factor Range:
0.40 to 1.00

Temperature Range (English):
23.0°F to 221.0°F

Accuracy (Temperature):
±0.3°C, ±0.5°F

Temperature Probe Calibration:
1 point temperature offset calibration

Backlight Option:
Yes

Data Points:
500 data sets with time and date

Data Management Details:
Continuous, Auto-Read and Timed read modes

Inputs:
8-pin MiniDIN for conductivity with built-in ATC

IP Rating:
IP54

Dimensions (L x W x H):
187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.

Weight (English):
1.54 lb.

Accuracy (Conductivity):
±0.5 % of the reading ± 1 LSD

Includes:
011050MD 2-cell K = 1.0 epoxy-body conductivity/ATC probe; 011007 1413 μS conductivity standard 5 x 60 mL; meter with electrode stand, PC cable, universal power adapter

Measurement Modes:
Conductivity with Temperature, Salinity with Temperature, TDS with Temperature

Cell Constant:
0.100 to 10.00 cm-1

Calibration Points (Conductivity):
1-5 points conductivity

Range (Conductivity):
0.00 μS to 500.0 mS

Temperature Compensation:
Linear (0 to 10 %/°C) or off

Temperature (Metric) Reference:
15.0, 20.0, 25.0 or 30.0°C

Resolution (Salinity):
0.01, 0.1 ppt; 0.01, 0.1 PSU

Salinity Measurement Modes:
Natural Seawater (ppt) or Practical Salinity (PSU)

Accuracy (TDS):
±0.5 % of the reading ± 1 LSD

Temperature Range (Metric):
-5.0°C to +105.0°C

Resolution (Temperature):
0.1°C, 0.1°F

Temperature Selection:
Manual or automatic with ATC temperature probe

Display Type:
5 in. backlit LCD

Memory:
Non-volatile

Log Function Type:
Automatic with Auto-Read and Timed read modes, manual with Continuous read mode

Alarm Output:
Calibration reminder alarm

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

AC Adapter:
Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

Weight (Metric):
700 grams

Warranty:
3 year meter warranty

Img

Thermo Scientific™

15-200-973PM

--


Description:
Orion Lab Star EC112 conductivity/salinity/TDS bench meter standard kit

Outputs:
Computer or printer (STARA-106)

For Use With (Application):
For a Wide Variety of Conductivity Samples in The 1 μS/cm to 20 mS/cm Range

Compatible Probes:
2-cell and 4-cell conductivity electrodes

Calibration:
__

Calibration Points:
__

Resolution (Conductivity):
0.01, 0.1, 1 μS; 0.01, 0.1 mS

Temperature Coefficient:
0 to 10 %/°C

Range (Salinity):
0.00 to 80.0 ppt; 0.00 to 42.0 PSU

Accuracy (Salinity):
±0.5 % of the reading ± 1 LSD

Resolution (TDS):
0.01, 0.1, 1 ppm; 0.01, 0.1 ppt

TDS Factor Range:
0.40 to 1.00

Temperature Range (English):
23.0°F to 221.0°F

Accuracy (Temperature):
±0.3°C, ±0.5°F

Temperature Probe Calibration:
1 point temperature offset calibration

Backlight Option:
Yes

Data Points:
500 with Date and Time Stamp

Data Management Details:
Continuous, Auto-Read and Timed read modes

Inputs:
8-pin MiniDIN for conductivity with built-in ATC

IP Rating:
IP54

Dimensions (L x W x H):
187.2 x 155.2 x 61.7 mm (7.37 x 6.11 x 2.43 in.)

Weight (English):
1.54 lb.

Accuracy (Conductivity):
±0.5 % of the reading ± 1 LSD

Includes:
011050MD 2-cell K = 1.0 epoxy-body conductivity/ATC probe; 011007 1413 μS conductivity standard 5 x 60 mL; meter with electrode stand, PC cable, universal power adapter

Measurement Modes:
Conductivity with Temperature, Salinity with Temperature, TDS with Temperature

Cell Constant:
0.100 to 10.00 cm-1

Calibration Points (Conductivity):
1-5 points conductivity

Range (Conductivity):
0.00 μS to 500.0 mS

Temperature Compensation:
Linear (0 to 10 %/°C) or off

Temperature (Metric) Reference:
15.0, 20.0, 25.0 or 30.0°C

Resolution (Salinity):
0.01, 0.1 ppt; 0.01, 0.1 PSU

Salinity Measurement Modes:
Natural Seawater (ppt) or Practical Salinity (PSU)

Accuracy (TDS):
±0.5 % of the reading ± 1 LSD

Temperature Range (Metric):
-5.0°C to +105.0°C

Resolution (Temperature):
0.1°C, 0.1°F

Temperature Selection:
Manual or automatic with ATC temperature probe

Display Type:
LCD

Memory:
Non-volatile

Log Function Type:
Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode

Alarm Output:
Calibration reminder alarm

Certifications/Compliance:
CE

AC Adapter:
Universal 100/240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

Weight (Metric):
700 g

Warranty:
3 Years

Img

Fischer Scientific

15-200-974

--


Description:
Orion Lab Star DO113 dissolved oxygen bench meter with stand

Outputs:
Computer or printer (STARA-106)

For Use With (Application):
Meter and Stand Option, Select and Purchase The Electrode Separately

Compatible Probes:
__

Calibration:
__

Calibration Points:
__

Resolution (Conductivity):
__

Temperature Coefficient:
__

Range (Salinity):
__

Accuracy (Salinity):
__

Resolution (TDS):
__

TDS Factor Range:
__

Temperature Range (English):
__

Accuracy (Temperature):
±0.3°C, ±0.5°F

Temperature Probe Calibration:
1 point temperature offset calibration

Backlight Option:
Yes

Data Points:
500 data sets with time and date

Data Management Details:
Continuous, Auto-Read and Timed read modes

Inputs:
9-pin MiniDIN for DO with built-in ATC

IP Rating:
IP54

Dimensions (L x W x H):
187.2 x 155.2 x 61.7 mm, 7.37 x 6.11 x 2.43 in.

Weight (English):
1.54 lb.

Accuracy (Conductivity):
__

Includes:
Meter with electrode stand, PC cable, universal power adapter

Measurement Modes:
Dissolved Oxygen (% Saturation with Temperature), Dissolved Oxygen (mg/L with Temperature), Dissolved Oxygen (ppm with Temperature)

Cell Constant:
__

Calibration Points (Conductivity):
__

Range (Conductivity):
__

Temperature Compensation:
__

Temperature (Metric) Reference:
__

Resolution (Salinity):
__

Salinity Measurement Modes:
__

Accuracy (TDS):
__

Temperature Range (Metric):
__

Resolution (Temperature):
0.1°C, 0.1°F

Temperature Selection:
Manual or automatic with ATC temperature probe

Display Type:
5 in. backlit LCD

Memory:
Non-volatile

Log Function Type:
Automatic with Auto-Read and Timed read modes, manual with Continuous read mode

Alarm Output:
Calibration reminder alarm

Certifications/Compliance:
CE, TUV 3-1, FCC Class A

AC Adapter:
Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets

Weight (Metric):
700 grams

Warranty:
3 year meter warranty